Military Engineer Services - Andhra Pradesh

39812057 repair / replacement of area drainage, culverts, paths hard standings, fencing, compound wall, gate etc under dgnp ( v ) .; 1 demolition of cement concrete inground floors andpavings not exceeding 15 cm thickness and removing rubbish off from the premises of md land, complete all as specified and directed. 2 demolition of reinforced cement concrete n.exc 15cm thick ( below or above ) ground level and removing rubbish off from the premises of md land, complete all as specified and directed. 3 demolition of stone / boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed. 4 material & labour for cement concrete 1:4:8, type d2 ( using40mm graded crushed granite stone aggregate ) as in foundations complete all as specified and directed. 5 material & labour for precast cement concrete 1:2:4, type b 1 ( using 20 mm graded crushed granite stone aggregate ) in landings, perforated cover slabs ( for man holes, drain etc. ) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:4, complete all as specified and directed. 6 material & labour for hardcore of stone boulder of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified and directed. 7 material & labour for 100 mm thick cement concrete 1:2:4 type b 2 ( 40 mm graded crushed granite stone aggregate ) in floors / pavings complete all as specified and directed. 8 material & labour for precast cement concrete block masonry with solid blocks type c 1, 1:3:6 ( 20mm graded crushed granite stone aggregate ) exc 10cm in width and set in cement mortar 1:6, complete all as specified and directed. 9 material & labour for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cm 1:6and finished the surface even and fair without using extra cement complete all as specified and directed. 10 material & labour for preparation of newly plastered surfaces and applying three coat of white wash on walls complete all as specified and directed. 11 supply & fixing of tmt bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed. 12 material & labour for providing cement concrete 1:2:4, type b 1 ( 20mm graded crushed granite aggregate ) as in coping etc. complete all as specified and directed. 13 material & labour for 100 mm thick plain cement concrete 1:4:8, type d 2 ( 40 mm graded crushed granite stone aggregate ) in sub base complete all as specified and directed. 14 material & labour for 20mm thick screed bed or bedding layer in cm 1:4 for laying tile etc. complete all as specified and directed. 15 material & labour for chequered cement concrete tiles 20cmx20cmx25mm thick , set, jointed and pointed in neat cement slurry in floor complete all as specified and directed. 16 dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed. 17 material & labour for sand filling for cushion bed below interlocking paver blocks complete all as specified and directed. 18 material & labour for machine pressed precast concrete interlocking paver block of any shape and size confirming to is 15658 2006 of 60 mm thickness, m 35 grade, jointed with grey cement and pigment complete all as specified and directed. 19 all as per item no 1.18 above but expect blocks. ( note: serviceable machine pressed precast concrete interlocking paver block will be obtained from item no. 1.16 above. ) 20 material & labour for providing precast cement concrete type c 1 1:3:6 ( 20mm graded crushed granite stone aggregate ) in cm 1:6 in window or door cills, lintels, bressumers, steps, quoin blocks ( for use with masonry ) , string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho rage blocks, bonders ( for stone walling ) . corbels, brackets, etc. ( of any section indicated ) , with plain fair faces, including chamfers, weatherings, throat ing etc. and setting in mortar complete with joints to match, complete all as specified and directed. 21 supply & fixing in repair galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. ( note: each line wire to be measured ) 22 supply & fixing for 4 mm diachain link fencing including line wires, any mesh, size100 x 100 mm and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. 23 supply & fixing for plates ( plain or chequered ) channels, square cut or notched ( ordinary and counter sunk ) forming holes, without any attachment confirm to fe 410 w ( gde e 250 ) quality a, complete all as specified and directed. 24 supply & fixing for mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets ( for securing wire mesh etc. ) including all necessary drilling, bolting , include welding or riveting, etc., and similar work conforming to fe 290 gde e 165 and also including to taking out old postsfromconcrete or earth, complete all as specified and directed. 25 material & labour for preparation of new surface of steel and ironworkof any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 26 material & labour for preparation of old painted surface of steel and ironworkof any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. 27 total in figures 28 quoted amount in words...

Archaeological Survey Of India - Andhra Pradesh

39102209 bids are invited for custom bid for services 1) providing new lighting arrangements for the displayed objects at nagarjuna konda museum, andhra pradesh 2) for providing repainting/white wash of nagarjunakonda valley cement model and replica of wooden stupa at nagarjuna konda museum, andhra pradesh. nagarjuna konda museum required upgrade with led spotlighting and wiring with mccbs, mcbs, switch boards etc which contains six galleries with 18500 sqft area. ...

Arcelor Mittal Nippon Steel India Limited - Andhra Pradesh

38914174 tender for 2000138888_upliftment of roads & drains at pelletplant vizag 1 2000138888 10 10 30 providing & laying of pcc 210 m3 110 vitrified flooring inclusive material. 265 m2 100 ceramic wall tilling works incl material 285 m2 90 r r masonery with 1:4 cement mortor 165 m3 130 white wash 325 m2 60 provid&laying of rcc(1:1.5:3)m30upto3mtr 275 m3 120 board making charges 700 m2 10 earth work excavation 1,850 m3 40 steel handling from 6mm dia to 32 dia 32.5 to 20 sand filling including sand ,watering, 285 m3 50 shuttering with material (centring) 1,750 m2 80 plastering internal 12mm 275 m2 70 brick work cc brick 185 m3 item details : sl. no. service description uom qty 1. earth work excavation m3 1,850.00 scope of work... earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on including getting out and disposal of excavated earth lead upto 50 m and lift upto plan) 1.5 m, as directed by engineer in charge. contractors scope... based on the job requirement, agency to engage the following equipments within a days notice in prior. a. ex 200 and ex 70, depends on site conditions anyone of the equipment will be utilized, should meet amns norms. b. manpower in the event of manual excavation with all statuary <(>&<)> ppes as per the instruction of the safety officer <(>&<)> engineer incharge. c. any damages to the property of amns property is chargable back, safety violations are subjected to penalty/order cancellation as per the safety guislines of the organziation. d. safety sign boards, barricades, tbts to be carried out with one safety officer <(>&<)> one safety marshall at all times. e. any spillages while shifting the excavated material should be immediately cleaned and will not be billed additional. 2. sand filing including sand, watering m3 285.00 scope of work... supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete etc as directed by engineer in charge. contractors scope... a.should be use natural sand only. b.material testing certificate from reputed testing agency. c.must be use vibro rollers with capacity of 15 tonnes. d.safety sign boards, barricades, tbts to be carried out with one safety officer <(>&<)> one safety marshall at all times. amns scope... a. water will be provided by amns. 3. providing <(>&<)> laying of pcc (1:4:8) m3 210.00 scope of work... pcc (1:4:8) providing and laying in position cement concrete of...

Hindustan Shipyard Limited - Andhra Pradesh

37648025 procurement of material required for r and m works in yard procurement of material required for r and m works in yard , good quality river sand , urinal basin waste pipe (watertec /polo or equivalent) , hand wash basin waste pipe (watertec /polo or equivalent) , 1/2 normal pvc tap (watertec /polo or equivalent) , 2 pvc drain pipe (light gauge) , 2 pvc 45 deg. bends , 1 inch cpvc pipes , cpvc solvent (m seal / ashivador equivalent) 100ml , grey colour emulsion paint , white colour emulsion paint , green colour emulsion paint , signal red emulsion paint , enamel grey paint , enamel blue paint , enamel green paint , enamel yellow paint , enamel black paint , surya cement white wash , emulsion paint brush 6 , emulsion paint brush 5 , painting brush 4 , painting brush 2 , birla white , hacksaw blade 10mm , shellac wood polish , take wood stainer (shellac make) (100ml) , rose wood stainer ( shellac make) (100ml) , emery paper grit 120 (jawan make) , emery paper grit 100(jawan make) , thinner , red brick / country bricks , fresh water tank 1000 ltr capcity (sintex, ashirvad or equivalent)...

Municipal Corporation - Andhra Pradesh

36162203 providing of terrace water proof with pressure grouting and crack filling and ceiling repair and white wash to the entire building of ward secretariat 30 of 19th division...

Municipal Corporation - Andhra Pradesh

35226140 providing of terrace water proof with pressure grouting and crack filling and ceiling repair and white wash to the entire building of ward secretariat 30 of 19th division, ananthapuramu...

Hindustan Shipyard Limited - Andhra Pradesh

34875924 procurement of bricks and white cement for rtype qtrs. repair works procurement of bricks and white cement for rtype qtrs. repair works , country bricks , surya cement white wash...

Municipal Corporation - Andhra Pradesh

34591469 providing of terrace water proof with pressure grouting and crack filling and ceiling repair and white wash to the entire building of ward secretariat 30 of 19th division, ananthapuramu...

Municipal Corporation - Andhra Pradesh

34591468 providing of terrace water proof with pressure grouting and crack filling and ceiling repair and white wash to the entire building of ward secretariat 30 of 19th division, ananthapuramu...

Municipal Corporation - Andhra Pradesh

34571723 providing of terrace water proof with pressure grouting and crack filling and ceiling repair and white wash to the entire building of ward secretariat 30 of 19th division, ananthapuramu...

Sainik School - Andhra Pradesh

33936762 request for proposal inviting sealed tenders ( single bid system ) for supply of general paint & white wash items for the year 2022 23 to sainik school korukonda 1 paint green ltrs asian 2 paint grey ltrs asian 3 paint ivory ltrs asian 4 paint maroon ltrs asian 5 paint aluminium ltrs asian 6 paint black ltrs asian 7 paint red ltrs asian 8 paint white ltrs asian 9 paint yellow ltrs asian 10 paint brown ltrs asian 11 paint golden brown ltrs asian 12 paint white aspa ltrs asian 13 paint blue ( oxford blue ) ltrs asian 14 gold paint ( artist ) ltrs asian 15 firose blue ltrs asian 16 thinner ltrs branded 17 thinner d 13 ltrs branded 18 paint brush 2 nos. branded 19 paint brush 4” nos branded 20 paint brush 5” nos branded 21 reds oxide ltrs branded 22 putty blade 4 nos. branded 23 putty blade 6 nos. branded 24 putty bag ( 01 kg pkt ) kgs latigrate 25 birla white cement kgs branded 26 distemper white kgs asian 27 javan water paper nos. branded 28 white cement ( blue ) kgs priya 29 stainer ltrs branded 30 iron brush 9” 31 iron brush 12” nos branded 32 wood primer ltrs branded 33 snowcem brick red ltrs asian 34 emulsion brick red ltrs asian 35 emulsion ming red ( epex ) kgs asian 36 emulsion white ( exterior ) ...

Sainik School - Andhra Pradesh

33708264 tender for dry ration, fresh vegetables, fresh fruits, cleaning and chemical items, laundry washing & chemical items, mixed cattle feed (mash), plumbing items & paint and white wash items etc, hiring of jcb services, hiring of shamiyana items, printing of stationary items, supply of building material items & outsourcing of tailoring shop & etc....

Military Engineer Services - Andhra Pradesh

32965241 replacement of defective light, repair and maint of lt panel board metering equipment, switch gears, day to day maint of 11 kv distribution cables, attending complaint and replacement of unsv ug cable gallery earthing, earthing strips all allied work replacement of defective light, repair and maint of lt panel board metering equipment, switch gears, day to day maint of 11 kv distribution cables, attending complaint and replacement of unsv ug cable gallery earthing, earthing strips all allied work servicing / maintinance ofmultiple section oflt panel board in one substation comprising minimum up to 05 nos acbs / mccbs / sdfs , busbar chamber, swich gear chamber, metering chamber cable termination / tray chamber after opening front / top / side / back cover by using forced air pressure andbrushes, cleaning of all dust / durt, complete cleaning of out side surface of panel board using suitable cleaning agents, tighting of all nuts & bolts of busbar / switchgear / cable terminals, repair / replacement to defective metering wiring from acb / mccb / ct to meter and replacement of defective meters, cts, indicator lamp, metering terminal blocks, mcb, replacement of defective aluminum cable lugs, nuts bolts washers, replacement of defective panel knob / door knob and hinges complete all as specified and as directednote: ( i ) panel meter, indicator lamp, mcb, busbarand ct will be measured and paid seperately as supply only. ( ii ) required aluminium cable lugs, metering cables and nuts bolts washers shall be inclusive of quoted rate. ( iii ) servicing / maintinance of acbs measured seperatelly. 2 all as per item no 1.00 above but comprisingacbs / mccbs / sdfs up to total 10 nos 3 all as per item no 1.00 above but comprisingacbs / mccbs / sdfs up to total 15 nos 4 all as per item no 1.00 above but comprisingacbs / mccbs / sdfs up to total 23 nos 5 all as per item no 1.00 above but comprisingacbs / mccbs / sdfs up to total 28 nos 6 servicing, repair, maintinance of air circuit breaker 630 amps to 3200 amps capacity by drawing out movable unit, forced air cleaning of movable and fixed unit, decarbonize breaker contracts and checking for any defects due to any flush / loose contact, cleaning of all fixed and moving contact point, terminal connection points with ctc, replacement of defective parts and re fixing acb, cables completes all as specified and as directed. note: ( a ) required male / female acb contacts, trip coils, closing coils, electronic protection unitwill be measured as supply only. ( b ) all cleaning agents are included in the quoted rate. 7 supply only fixed contract of acb 630a to 3200acomplete all as specified and as directed 8 supply only moving contract of acb 630a to 3200acomplete all as specified and as directed 9 supply only electronic protection unit of acb 630a to 3200acomplete all as specified and as directed 10 supply only shunt trip coil of acb 630a to 3200acomplete all as specified and as directed 11 supply only closing coil acb 630a to 3200a complete all as specified and as directed 12 supply only digital electronic ammeter ( 0 3200 amps range ) withbuilt in selector switch suitable for lt 415 v panel flush pattern square type 96 mm x 96 mm with adopter completeall as specified and directed. cat part no: 30002385 ( dm3110 ) make: schneider or conserve / l&t / hpl 13 supply only digital electronic volt meter ( 0 500 volts range ) withbuilt in selector switch suitable for lt 415 v panel flush pattern square type 96 mm x 96 mm with adopter completeall as specified and directed. cat part no: 30002386 ( dm3210 ) make: schneider or conserve / l&t / hpl 14 supply only indication lamps ( led type ) red, yellow and blue in colours of 22.5 mm dia to monitor on lt panel board suitable for 240 v ac supply and taking down unserviceable indication lamps complete all as specified and directed. cat part no: 1sfa619402r5201 make: siemens / c&s / schneider / abb 15 supply only metering current transformer of 1000 / 5 amps class 1, 15 va, completeall as specified and directed by engr in charge.make: rishabh or equivelent of kappa / ae 16 supply only metering current transformer of 1200 / 5 amps class 1, 15 va, all complete all as specified and directed.make: rishabh or equivelent of kappa / ae 17 supply only metering current transformer of 1600 / 5 amps class 1, 12.5 va, complete allas specified and directed.make: rishabh or equivelent of kappa / ae 18 supply only metering current transformer of 2000 / 5 amps, class 1, 12.5va, complete all as specified and directed. make: rishabh or equivelent of kappa / ae 19 supply only metering current transformer of 2500 / 5 amps, class 1, 5va, complete all as specified and directed. make: rishabh or equivelent of kappa / ae 20 supply only metering current transformer of 3000 / 5 amps, class 1, 1.5va, complete all as specified and directed. make: rishabh or equivelent of kappa / ae 21 supply only metering current transformer of 800 / 5 amps, class 1, 2.5va, complete all as specified and directed. make: rishabh or equivelent of kappa / ae 22 supply only switch disconnector fuse unit , tpn , open execution, bolted fuse link, 415v, conforming to is / iec 60947 3, telescopic shaft for depth adjustment terminal shrouds on both side, door interlock facility of current rating 250 amps including boted hrc fuse 03 nos ( make l&t, cat no fn 250 tpn sk 95682 & hrc fuse st 30781 or equivelent of siemens / abb / havells ) 23 all as per item no 22.00 above but capacity of 400 amps. ( make l&t, cat no fn 315 tpn sk 95591 & hrc fuse st 30784 or equivelent of siemens / abb / havells ) 24 supply only hrc fuse of capacity 400 ampscomplete all as specified and as directed ( make l&t cat no sf94335 and equivalent to standard / ge / schneider ) 25 supply only hrc fuse of capacity 250 ampscomplete all as specified and as directed ( make l&t cat no sf94333 and equivalent to standard / ge / schneider ) 26 supply and fix mccb, 4 pole, 400 amp, 36 ka braking capacity, ics = 100% icu as per iec 60947 2, with micrologic 2 ( up asic based ) , complete all as specified and as directedmake schneider cat part no lv432677 or equivelent of legrand / abb 27 all as item no 26.00 above but of size 4 pole, 630 amp, 36 ka. make make schneider cat part no lv432877 or equivelent of legrand / abb 28 all as item no 26.00 above but of size 4 pole, 250 amp, 36 ka. make make schneider cat part no lv431780 or equivelent of legrand / abb 29 all as item no 26.00 above but of size 3 pole, 160 amps, 36 ka. make schneider cat part no lv430770 or equivelent of legrand / abb 30 supply and fix mccb 3 pole, 125 amps, 25 ka braking capacity, ics = 100% icu as per iec 60947 2, with thermal magnetic trip unit. complete all as specified and as directed make schneider cat part no lv430311 or equivelent of legrand / abb 31 supplay, fix and connecting by mannualchangover switchsheet steel enclosure versionconforms to iec 60947 3 of capacity 630 amps four pole complete all as specified and as directed ( make l&t cat part no co46300osooor equicalent to havells / indo asian. 32 supplay, fix and connecting by mannualchangover switchsheet steel enclosure versionconforms to iec 60947 3 of capacity 400 amps four pole complete all as specified and as directed ( make l&t cat part no co44000osooor equicalent to havells / indo asian. 33 supplying and laying synthetic rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per is 15652 2006, ( superseding is 5424 ) suitable for electrical shock safety of sizes 2m x 1m.complete all as specified and as directed 34 m&l for painting of outer surface of multiple section ofcomplete lt panel board size up to 5.5 m x 3.2 in one substation comprising acbs / mccbs / sdfs , busbar chamber, swich gear chamber, metering chamber cable termination / tray using one coat of synthetic enamel paint after preparation of surface, providing protection cover to all metering equipment, panel meters, switchgears, cleaning of all meters and switch gearscomplete all as specified and as directed 35 all as per item no 34.00 above but lt panel board size up to 7.5 m x 4.5 m. 36 m&l for painting of both side surface of ms cable trench cover using one coat of black bituminius paint after preparation of surfacecomplete all as specified and as directed 37 m&l for plate girder or single stanchions, fe 290 built up of one beam or channel section with flange plates, caps bases, splices, angle brackets, cleats and other connection and taking out of oldunsv ms cable cover / support structure. 38 dimantling, taking out all earth connection of strip from panel board to earth test pit any size and replace the worn out earth strip, nut / bolts / washers connect all joint with new nots, bolts and washers to in original positioncomplete all as specified and as directednote : earth gi strip measured and paid separetely 39 m & l for earth continuity conductor gi strip of size 32 x 6 mmcomplete all as specified and as directed 40 m&l for writing letter and fixing lt panel boardsurface showing incoming and outgoing capacity inamps and feeder name of letter five not less than 30 x 50 mm complete all as specified and as directed 41 dismantlingexisting unserviceable / corrodedlt pillar box and supply, fabricate, install, testing and commissioning out door type, double door dust & vermin proof lt pillar box of 2.1 m length, 1 m width & 1.6 m height fabricated vertically by using 50x50x5 mm angle iron frame, fixing with nuts & bolts on 75 x 40 mm ismc as per directions of engineer in charge and using 3 mm thick crca ms sheet all over body front and back cover with hinges and aldrops for locking arrangments, 1 mm thick frp coating all over the external surfaces and 3 mm thick ms sheet for bus bar cover, piller box, partitions and bottom cable entry covers duly painted with one coat of redoxide and two coats of synthetic enamel paint including control wiring complete in lt piller box with 1.5 sq mm frls copper conductor cable and 5a mcb sps 2.5 amp for meters, breaker control supply and indication lamps and provision to accommodate the following: ( a ) 3 ph+1n copper busbar of equal sizes of capacity 1.5 times of ratedcurrent of incoming switchgear. ( b ) 3 ph+1n copper busbar of equal sizes of capacity 1.5 times of ratedcurrent of outgoing switchgears as down links / connectivity links to switchgear. 42 ( c ) digital ammeter & voltmeter for incoming & digital ammeter for outgoing. ( d ) led indication lamps for ryb for incoming and outgoing indication. ( red, yellow & blue coloured ) ( e ) lt acb – 1600amps, 4p, 50ka, complete with over current and earth fault tripping device as incomer 01no ( f ) lt acb 1600 amps, 3p, 50 ka complete with over current and earth fault tripping device as out going 01 no ( g ) mccb 630amps, 3p, 36ka complete with over current and earth fault tripping device as out going 01no ( h ) mccb 400amps, 3p, 36ka complete with over current and earth fault tripping device as outgoing 01nonote : ( i ) unit rate quoted include for necessary grouting / chipping of concrete and anchor fastners and providing necessary pcc ( 1:2:4 ) type b1 using 20 mm gradedcrushed stone agreegate for foundation to fix the lt piller box. ( ii ) cost of digital ammeter, voltmeter, led lamps, cts, lt acbs, mccbs and mcbs shall be included in the quoted rate. ( iii ) drawing shall be got approved by ge before fabrication of the lt piller box. ( iv ) all incoming and outgoing cable connections are to be made as per existing one and rate deemeded to be included in the quoted rate. ( v ) the pillar box shall be brought to jetty gallery part by part and to be assembled in site being limited space of work / movement and rate shall deemed to be included in quoted rate. ( vi ) copper busbars with pvc sleeves shall be measured and paid seperately under respective item in this schedule as supply only 43 supply only copper bus bar links with pvc sleeves of raing 630 a to 2000 acomplete all as specified and as directed 44 supply and fix lt acb 4 pole4000 a, 50 ka breaking capacity, 415 v, 50 hz, manual drawn out type and manually charged with micro processor et2l trip unit ( without display ) release protection system against over current, earth fault and short circuit with 2 no + 2 nc auxiliary switch, safety shutter, cradle guard, operating handles conforming to iec 60947 2 & 3complete all as specified and as directedmake: cat.no. mvs40n4mw2lofschneider / l&t / abb / ge / legrand 45 all as per item no 44.00 above but of capacity2000amps, 4polecat.no. mvs20n3mw2lof schnider equivelent make inl&t / abb / ge / legrand 46 all as per item no 44.00 above but of capacity1600amps, 4polecat.no. mvs16n3mw2l of schnider equivelent make inl&t / abb / ge / legrand 47 all as per item no 44.00 above but of capacity1250amps, 4polecat.no. mvs12n3mw2l of schnider equivelent make inl&t / abb / ge / legrand 48 all as per item no 44.00 above but of capacity1000amps, 4polecat.no. mvs10n3mw2lof schnider equivelent make inl&t / abb / ge / legrand 49 attending day to day electrical complaints and call on repair of control panel of street light, security light, garden light, perimeter light, tower light & high mast light providedinsidedockyard, decarbonizing all contact points of contactors , replacement of wornout aluminium cable lugs, wornout screws, nuts, bolts and washers, tightening the loose connections whereever required, adjustment of timer, cleaningand restore the power supply complete all as specified and as directednote : ( i ) replacement of spares vizmcb, mccb, contactors, timers, cables, will be measured and paid for separately as supply only and labour element for taking down the replaced spares shall be deemed to include in the unit rate quoted. ( ii ) if the qty of complaints to be attended in a control panel / lt panel is more than 01 no in a day, altogether the complaints will be considered only 1 ( one ) . ( iii ) the contractor has to engage qualified electricians and helpers in sufficient nos to attend and rectify the defects. ( iv ) job card for repairing work will be issued by concern je and the same shall be signed by contractor / or his rep and shall be returned to concerned je on completion of each job work. 50 material and labour for disconnecting the burnt out high mast tower winch motor 3 phase , 415v, 50hz, 1400 rpm, 4 pole, 2hp and rewinding with supper enameled copper wire of same gauge / size of wire including re fixing the same in its original position testing and commissioning complete all as specified and as directed 51 material and labour for servicing of high mast tower control mechanism by greasing and varnishing of electric motor 2 hp, 3 phase 415 volts 50hz including replacement of unsv plug and socket for trouble free functioning including painting of starter panel with one coat of synthetic enamel paint complete all as specified and as directed 52 supply and fixing high mast tower winch motor 3 phase 415 v 50hz 1400 rpm 4 pole 2hp complete all as specified and as directed 53 s&f pvc junction box of outdoor type, weather proof, with provision of hole at bottom for cable entry, hinged door with locking arrangement, of size not less than 200mm ( l ) x 100mm ( b ) x 300mm ( h ) incl taking down unserviceable one, fixed to pole with ms clamp, nuts, bolts and washers complete including one 3ph 4 pole connection block. complete all as specified and as directedmake syntex / hansel 54 supply and fixing / laying through trench.surface or wall including required necessary saddle / clamp any highthdpe double wall pipe corugated pipe of size 40 mm dia for cable protection laid in trenches in lieu of sand / brick protection complete all as specified and as directed 55 taking out old unserviceable lt ug cable of any size any description including hdpe pipe and bricks for cable protection where ever appeared and complete all as specified and as directed 56 supply and laying in trenches xlpe insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade cross section area 6 sqmm 2 core and connection complete with aluminium cable lugscomplete all as specified and as directed 57 all as per ser no 56.00 but of size 10 sqmm, 4 core 58 all as per ser no 56.00 but of size 16 sqmm 4 core 59 all as per ser no 56.00 but of size 25 sqmm 3.5 core 60 all as per ser no 56.00 but of size 35 sqmm 3.5 core 61 m&l for dismatling and taking out street light cable loop near pole forsize of cable 6sqmm to 25 sqmm after dismantling connection from junction box, cutting, removing damaged portion of the cable ends, providing new aluminium cable end terminals, laying of cable through protection pipe through coping to junction box including necessary connection complete all as specified and as directed. ( note: earth work, pole coping pcc, cable protection, pipe measured separately ) 62 m&l for dismantling taking out cables 10 sqmm to 16 sqmm from trench, including making straight through joints at damaged portion and relaying to trench complete all as specified and as directed ( note: earth work, hdpe pipe for cable protection will be measured and paid separately. heat shrink straight through cable joints inclusive of quoted rate ) 63 m&l for dismantling taking out cables 25 sqmm to 35 sqmm from trench, making straight through joints at damaged portion and relaying to trench complete all as specified and as directed ( note: earth work, hdpe pipe for cable protection will be measured and paid separately. heat shrink straight through cable joints inclusive of quoted rate ) 64 supply and fixing pvc insulated, pvc round shethed copper flexible electric cable 1.5 sqmm 3 core, 1100 volts grade and dismantling wornout / defective cables from sl / flood light fitting at pole / tower top to jb at bottom of pole through pole / tower complete all as specified and as directedmake : plaza / gloster / havells / polycab. 65 m&l for complete servicing, repair, maintenance of timer panel, by cleaning inside and outside, replacement of burnt mcb, mccb, timer, contactor, wiring, bypass toggle switch complete all as specified and as directednote: replacement of mcb, mccb, timer, contactor shall be measured as supply only 66 supply only power contactor 3 phase, 415v, 32 amps cap utilsed for heavy duty by taking down the old perished / deteriorated contactor complete all as specified and as directedmake: schneider, model etvs lc1e3201 or equivelent of legrand / l&t / abb 67 supply only surface mounting analog time switchesheavy duty of 230 v 50hz including dismantling taking down unsv one and complete all as specified and as directedmake : 6499 15 maxi rex 4qt ( daily ) of legrand or equivelent of abb / l&t 68 supply only mcb, sp, 10ka, c 6 32 a including dismantling taking down unsv onecomplete all as specified and as directedmake: schneider or equivelent of legrand / abb / l&t 69 supply only mcb, dp, 10ka, c 40a 63 a including dismantling taking down unsv one complete all as specified and as directed make: schneider or equivelent of legrand / abb / l&t 70 supply only mcb, 4p, 10ka, c 40a 63 a including dismantling taking down unsv onecomplete all as specified and as directedmake: schneider or equivelent of legrand / abb / l&t 71 supply only mccb with thermal magnetic release, 16 ka, 3 pole, 415v, 100 a, complete all as specified and as directedmake: schneider , model easy compact cvs 100 bs, lv510950 to 58 or equivelent of legrand / abb / l&t 72 m&l for dismantling of non functional street light / flood lightfrom any type of pole at hight upto 9 mtr by suitable ladder for repair of the same for replacement unserviceable items like led driver, connector block and decarbonising contact points and refixing the same to pole after repair of any type securitylight .note: required led driver shall be measured and paid separately 73 supply only led driver suitable for street light fitting 1x 120 watt, 230v, make cg / halvells / bajaj / philips / wipro 74 supply only led driver suitable for street light fitting 1x 150 w , 230v, make cg / halvells / bajaj / philips / wipro 75 supply only led driver suitable for flood light fitting 1x 200 w, 230v, make cg / halvells / bajaj / philips / wipro 76 supply only led driver suitable for flood light fitting 1x 250 w, 230v, make cg / halvells / bajaj / philips / wipro 77 s&f on wall / pole timer enclosure out door type complete with timeranalog time switchesheavy duty of 230 v 50hz, power contactor 3 phase mnx 18 , 415v, 32 amps, mcb, tpn, 10ka, c 40a 63 a with, rotary switch with connector for incoming and outgoing cable entry complete all as specified and as directedmake indi asian / havells 78 m&l for painting of steel fabricated light tower not less than 10 mtr high with one coat of aluminium paint after preparation of complete surface complete surface including writing tower number with synthetic enamel black paint complete all as specified and as directed 79 m&l for painting of steel tubular pole any type / swan neck pole with one coat of aluminium paint after preparation of complete surface including writing pole number with synthetic enamel black paint complete all as specified and as directed 80 m&l for white wash to pole coping pcc complete all as specified and as directed 81 s & f street light fitting led 150 watt watt incl dismantling taking down unsv one complete all as specified and as directed.make cg or equivelent of halvells / bajaj / philips / wipro 82 s & f flood light fitting led 210 watt watt incl dismantling taking down unsv one complete all as specified and as directedmake cg or equivelent of halvells / bajaj / philips / wipro 83 s & f flood light fitting led 300 watt incl dismantling taking down unsv one complete all as specified and directed, make cg, model cfs 501 300 57 60d sl gl ngg or equivelent of halvells / bajaj / philips / wipro 84 s & f flood light fitting led 350 watt incl dismantling taking down unsv one complete all as specified and directed, make cg, model cfs 501 350 57 60d sl gl ngg or equivelent of halvells / bajaj / philips / wipro 85 taking down old unserviceable aviation light fitting, and supply & fix new led aviation light fitting withyellow painted die cast aluminium alloy housing, red coloured polycarbonate dome and accessories includingclamps, nuts, bolts and service connections up to the junction box complete all as per make bajaj andcat no.bjaol 2 bc gls 2 x 100w bc bajaj or eqiuvalent in philips / cg / havells / wipro. 86 excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft loose soil for cable work or from above cable duct complete all as specified and as directed 87 returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed. 88 removing of excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. 89 m&l for dry sand cushioning for under groundcable provided with layer and sand 8 cm deep before laying the cable and 15cm after laying the cable complete all as specified and as directed. 90 supplying and laying un reinforced precast concrete cable cover, class hv, type 1, flat, size 300mm x 180mm x 40mm complete all as specified and as directed 91 surface dressing of areas of above cable duct by clearing away all grass, wild vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30cm girth and removing rubbish upto a distance of 50 meters outside the periphery of the area under clearance complete all as specified and as directed 92 m & l making chequrered plates as per existing sizes and thickness both side lifting handle as per existing one including painting of one coat red oxide primerand two coat of black bituminius paint, including necessary pcc wks as per site requirment and taking out of old unsv chequered plate complete all as specified and directed. 93 cleaning of cable duct of size 1.2 x 1.0 by removing out all mud, soil, waste materials and disposal of waste materials to nearest gurbage bin and soil mud to low laying area of dockyard 94 s / f of cable rack made with structural steel section of isa 75x75x8mm, ( fe 290, gde e 165 ) pre welded, inside duct, on wall , placing in position and fixing to wall with fastener steel bolt not less than20 mm dia, including painting with one coat of red oxide and two coat of black bituminous paint all as specified and directed. note: cable rack drawing shall be obtained from engr in charge. 95 dismantling taking out unserviceable ms cable support from wall / surface of gallery any type by removing nuts & bolts / cutting braces complete all as specified and as directed 96 taking out old unsv ht ug cable of any size and any description including gi pipe of any dia and bricks for cable protection where ever appeared and complete all as specified and as directednote: ( 1 ) excavation and earth work shall bemeasured and paid separately. ( 2 ) serviceable cable obtained shall be stacked properly for re use. 97 m & l xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric power cables ( heavyduty ) with aluminium conductor, 11000 volts earthed, grade cross sectional area 185 sq. mm 3 core complete all as specified and as directed 98 all as per item no 97.00 above but for cable sizes 240 sqmm 3 core 99 all as per item no 97.00 above but for cable sizes 300sqmm 3 core 100 all as per item no 97.00 above but for cable sizes 400sqmm, 3 core 101 supply only cable jointing kit for 11 kv ( earthed ) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 185 sqmm incl dismentling / taking down unserviceable one complete all as specified and as directed 102 all as per item no 101.00 above ( indoor termination ) but for cable of size 240sqmm to 300 sqmm incl dismentling / taking down unserviceable one complete all as specified and as directed. 103 all as per item no 101.00 above ( indoor termination ) but for cable of size 400 sqmm incl dismentling / taking down unserviceable one complete all as specified and as directed. 104 supply only cable joining kit for 11 kv ( earthed ) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 185sqmm incl dismentling / taking down unserviceable one. 105 all as per item no 104.00 above ( straight through heat shrink type joint ) but for cable of size 240sqmm to 400 sqmm incl dismentling / taking down unserviceable one complete all as specified and as directed. 106 m & l for road cutting / hard standing to a depth not less than 80 cm and not less than 60 cm wide for laying of gi pipe to draw to ugcable and making good the disturbed surface by filling of pcc ( 1:3:6 ) type c 2 using 40 mm graded stone aggregate and finished the surface even and smooth with out using extra cement and disposal off the surplus debris and soil to a distance not exceeding 50 m complete all as specified and as directed by engr in charge. 107 m & l 80 mm bore gi pipe tubes light grade for cable protection supporting with all fixing accessories ( clamp, nuts, bolt and washer etc ) complete all as specified and as directed by engr in charge. 108 dismantling taking out ht cable from cable rack / floor at gallery of marine jetty for repair / replacement of wornout steel cable rack or for realingnment of cable and refixingthe cables with proper staking with proper alignment of cable on repaired / existing rack and making feeder wise bundle of cable using pvc cable tie for sizes of cable 3 core, 185 to 240 sqmm, 11000 volts grade complete all as specified and as directed. note: each cable shall be measured separately.steel cable rack shall be measured separately as supply and fix 109 all as per item no 108.00 above but for cable sizes 300 to 400 sqmm, 3 core. 110 m&l for finding of cable fault of ug 11000 volts grade cable inside trench ( under soil / drain / pcc / road / trench ) by disconnecting both cable ends, using insulation tester, cable path / fault finder and rectification complete by necessary excuvation, cutting at fault position, fixing of straight through heat shrink joint, for cable sizes 185 sqmm to 400 sqmm, 3 core, 11000 volts grade or replacement of heat shrink indoor cable joint kit of size 185 sqmm to 400 sqmm, 3 coreand reconnection of both cable end to original position after complete satisfactory insulation test, fixing with old or required new nuts bolts washers complete with testing complete all as specified and as directednote: ( a ) items required for rectification such as heat shrink indoor cable joint kit / heat shrink straight through joints / heat shrink sleeves and earth work shall be measured separately . ( b ) required aluminium cable lugs and nuts bolts washers shall be inclusive of quoted rate. ( c ) contractor shall bring necessary testing equipment and rate shall be inclusive of quoted rate. 111 m&l for earthing complete with glvn. gi plate earth electrode 60cmx60cmx6 mm thick burried in ground vertically to a depth n. less than 1.5 m below normal gl, connected to gi strip32x6 mm earth lead by means of nuts, bolts, check nuts & washers all as specified and indicated inclu. concrete pit in pcc 1:3:6 type c 2 rcc, precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia ms rod fixed flush to pit, funnel, wiremesh, 20mm dia gi pipe medium grade for watering charcoal and salt in alternate layers including necessary earth work excuvation & removal etc complete all as specified in plate no 5 of ssr part i 1991 ( zone e ) 112 m & l for earth continuity conductor gi strip of size 32 x 6 mm . 113 painting chequrered plates as per existing sizes and thicknessof one coat red oxide primerand two coat of black bituminius paint, complete all as specified and as directed 114 supply and fix cable route indicator to indicate path of ht cable 11000 volte material usde cast iron with pcc work complete all as specified and as directed...

Hindustan Shipyard Limited - Andhra Pradesh

32558316 procurement of plumbing and other materials required for nauka bungalow, c8 and vp 3 bungalows procurement of plumbing and other materials required for nauka bungalow, c8 and vp 3 bungalows , 110mm door bend , 110mm door tee , 110mm plan tee , 110mm gi clamps , ½” concealed valve ( plaza ) , ½” fabt ( cpvc ) , 110mm pipe ( sudhkar ) , 110mm plan bend , cp shower rose , wash basin set. , surya cement white wash , french polish...

South Central Railway - Andhra Pradesh

29926609 supply of supply of r.c.c. earth pit box of size 450 x 450 x 50mm including cover of size 450 x 450 x 4.5mm along with white wash.supply of r.c.c. earth pit box of size 450 x 450 x 50mm including cover of size 450 x 450 x 4.5mm along with white wash.,supply of r.c.c. earth pit box of size 450 x 450 x 50mm including cover of size 450 x 450 x4.5mm along with white wash....

Military Engineer Services - Andhra Pradesh

29727203 as as to flooring of common area mwo mso newn and cyo corridor workstations equipment furniture and washroom works in bldg no p45 at as as to flooring of common area mwo mso newn and cyo corridor workstations equipment furniture and washroom works in bldg no p45 at comnetcen special repairs to rcc overhead water tank at various building of kalyani and provn of acp cladding at 1.00 dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) and disposal of debris and rubbish to outside md land complete all as specified and directed. 2.00 m & l for glazed, coloured, ceramic, joints free tiles of size ( 350mm x 250 mm / 450mm x 350mm / 300mmx450mm ) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. 3.00 m & l for non skid, ceramic, coloured tiles 7 to 8 mm thick ( square / rectangular ) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. 4.00 s & f powder coated ( minimum 50 micron ) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. ( note : ( i ) thickness of aluminium section shall not be less than 1.5 mm ) . 5.00 s & f 4.8 mm thick, sheet glass, ordinary quality and glazing with oil putty in square exceeding 0.5 sqm in each pane complete all as specified and as directed. 6.00 m & l for use & waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick ( horizonal or sloping ) for flat rough finished surfaces of concrete complete all as specified and directed. 7.00 m & l for reinforced cement concrete 1:1.5:3, type a 1 ( nominal mix ) ( using 20 mm graded stone aggregate ) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, etc complete all as specified and directed. ( note : reinforcement will be measured & paid seperately ) 8.00 s & f high strength corrosion resistanttmt steel bars 6mm to 8mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. 9.00 dismantling boarding, any description, fixed in any position with nails etc complete all as specified and directed. 10.00 s & f 18 / 19 mm thick, plywood, grade bwp, type bb, fixed with screws to timber frame work, etc complete all as specified and directed. 11.00 s & f 0.90 mm thick, decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturers instructions complete all as specified and directed. 12.00 s & f continuous ( piano ) hinges, mild steel, bright finish or electrogalvanised, 30mm width of flape when open complete all as specified and directed. 13.00 m & l for vitrified, designed, dark shade coloured ( light shade ) , tiles, 10 mm thick, ( square / rectangular ) polished, area of each tiles not exc 0.36 sqm, in floors, etc including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. 14.00 m & l for non skid, ceramic, coloured tiles 7 to 8 mm thick ( square / rectangular ) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. 15.00 taking down existing aluminium aluminium partition of any size and descriptions and and refixing in same position after carry out repair work complete all as specified and directed. 16.00 s & f powder coated ( minimum 50 micron ) anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg / m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. and anodised aluminium fittings such as peg stay 150mm long ( 01 no ) , hinge type b 21, 100mm long ( 02 nos ) and suitable size of handle complete all as specified and directed. 17.00 demolition of un reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, ( below or above ground level ) and disposal of debris and rubbish to a distance upto outside md land complete all as directed by the engr in charge 18.00 m & l for 25 mm thick, plain cement concrete 1:2:4, type b 0 ( using 12.5 mm graded stone aggregate ) as in sub base of flooring, etc and finished the surface even and rough complete all as specified and directed. 19.00 m & l for preparing old plastered surfaces of walls by complete removal of existing treatment and applying two coats of distemper oil emulsion over a coat of alkali resistant priming coat over one or more coat of wall care putty complete all as specified and directed. 20.00 m & l for 12 mm thick, prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed. 21.00 s & f 75 mm size hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed. 22.00 s & f 100 mm size, stainless steel designer pull handle, fabricated type polished complete all as specified and directed. 23.00 m & l for 18 to 20mm thick granite ( of any type ) work ( table rubbed and polished ) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar ( 1:4 ) including pointing in white cement ( 1:2 ) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. 24.00 s & f in repairs, towel ring square with round flange including chromium plated brass screws and wooden / plastic cleats etc complete all as specified and directed. ( make: jaquar cat no. acn 1121n or equivelant of make as per list of manufacturers ) 25.00 s & f in repairs, towel rack 600mm long with lower hangers, stainless steel including chromium plated brass screws and wooden / plastic cleats etc complete all as specified and directed. ( make: jaquar cat no. akp 35781ps or equivelant of make as per list of manufacturers ) 26.00 s & f in repairs, 15mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. 27.00 s & f in repair 15 mm bore, hand shower ( health faucet ) ( abs body ) with 8mm dia, 1.2 meter long spirochrome flex tube & wall hook complete all as specified and directed. ( make: jaquar cat no. ald 587 or equivelant of make as per list of manufacturers ) 28.00 s & f in repairs, 15mm bore, bib taps, 2 in 1, fancy type cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. ( make: jaquar cat no. flr 5041n or equivelant of make as per list of manufacturer ) 29.00 s & f in repair paper holder with flap recessed type ( stainless steel ) fixed to wall with brass screw complete all as specified and directed. ( make: jaquar cat no. ahs 1553 or equivelant of make as per list of manufacturers ) 30.00 s & f in repairs, vitreous cliina wash basin, angle back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed. 31.00 s & f in repairs, vitreous china wash basin, thin rim table top basin, shape round, size: 480x480x135mm excluding taps etc complete all as specified and directed. ( make : jaquar cat no. ops wht 15901n or equivalent of make as per list of manufacturers ) 32.00 s & f in repair 15 mm bore, pillar taps, single lever tall boy with 150mm extension body fixed spout without popup waste system with 600mm long braided hoses, screwed for iron pipe complete all as specified and directed. ( make: jaquar cat no. flr 5005nb or equivelant of make as per list of manufacturers ) 33.00 s & f in repairs, 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. 34.00 s & f in repair 15 mm bore, angular stop cock with wall flange, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. ( make: jaquar cat no. kup 35053pm or equivelant of make as per list of manufacturer ) 35.00 s & f in repairs vitreous china urinal, with all fixing accessories set, of size 375 x 315 x 620mm, starwhite with grating and union for discharge pipe ( excluding flushing cistern, flush pipe & waste pipe ) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and directed. ( make: jaquar cat no. urs wht132530 or equivelant of make as per list of manufacturers ) 36.00 s & f in repairs, vitreous china bowl urinal flat back, of size 465x355x265mm, white ( minimum ) with grating and union for discharge pipe ( excluding flushing cistern, flush pipe & waste pipe ) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and directed. 37.00 s & f in repairs vitreous china rimless single piece wc with uf soft close slim seat cover, hinges, fixing accessories, accessories set and cistern fittings, size: 380x725x690 mm, s trap 300 mm and all fittings and fixtures including connection to outgoing drain including making good damaged / disturbed surfaces complete all as specified and directed. ( make: jaquar cat no. ons wht 10853s300ufsm or equivelant of make as per list of manufacturers ) 38.00 s & f in repairs, vitreous china wash down water closet pan ( pedestal pattern ) , white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with seat and cover complete but excluding flushing cistern & flush pipe including making good damaged / disturbed surfaces complete all as specified and directed. 39.00 s & f in repairs, vitreous china squatting pan, orissa pattern, size 580 x 440 mm white with integral foot rest and p or s trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and directed. 40.00 s & f in repairs, 10 litre capacity, pvc valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed. 41.00 s & f in repair 32 mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. 42.00 s & f in repairs, 32mm dia flexible pvc waste pipe for wash basin / sink etc complete all as specified and directed 43.00 s & f in repairs 5mm thick, bevelled edge looking mirror of size 1200mmx800mm of selected quality glass, mounted on 6mm thick ac building board or commercial plywood and 1st class hard wood designer frame around the mirror with pretruded stainless steel metal studs and fixed to wooden plug with chromiun plated brass screws and cup washers complete all as specified and directed. 44.00 taking up or down 15mm bore, steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. 45.00 taking up or down 20mm bore, steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. 46.00 supply, laying, connection and testing, 15mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. 47.00 supply, laying, connection and testing, 20mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. 48.00 taking down eaves gutters and rainwater / soil / waste pipes ( any size or pattern ) , including all fittings, heads, shoes, bends, swan necks, etc., including removal to store ( measured overall as fixed along the centre line over fittings and accessories ) complete all as specified and directed 49.00 s & f 110 mm bore, pvc ( swr ) , soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed. 50.00 s & f 75 mm bore, pvc ( swr ) , soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed. 51.00 s & f 110 mm bore, pvc ( swr ) bends of any radius complete all as specified and directed. 52.00 s & f 110 mm bore, pvc ( swr ) bends of any radius with oval access door complete all as specified and directed. 53.00 s & f 75 mm bore, pvc ( swr ) bends of any radius complete all as specified and directed. 54.00 s & f 75 mm bore, pvc ( swr ) bends of any radius with oval access door complete all as specified and directed. 55.00 s & f 110 mm bore, pvc ( swr ) vent cowl complete all as specified and directed. 56.00 s & f in repair 75 mm bore, pvc ( swr ) floor trap, with grating including jointing to waste pipe fixed in cement concrete type b 1 ( 1:2:4 ) complete all as specified and directed. 57.00 m & l for preparation old plastered surfaces of walls of any description over 10 cm width or girth not otherwise described by complete removal of existing treatment and applying two coats of plastic emulsion paint over a coat of primer over one or more coats of wall care putty to a smooth surface complete all as specified and directed. 58.00 m & l for preparing new surfaces of internal ceiling, etc by complete removal of existing treatment and applying two coats of distemper oil emulsion over a coat of alkali resistant primer and over one or more coats of wall care putty to a smooth surface complete all as specified and directed. 59.00 s & f solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and as directed. 60.00 demolition of reinforced cement concrete in any position not otherwise specifically provided for and removing rubbish to outside md land complete all as specified and directed. 61.00 s & f high strength corrosion resistant tmt steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. 62.00 m & l for plain cement concrete ( 1:2:4 ) , type b1 ( using 20mm graded stone aggregate ) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed. 63.00 m & l for mild steel hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets ( for securing wire mesh etc. ) including all necessary drilling, bolting or riveting, etc., and similar work conforming to fe 290 gde e 165 ® complete all as specified and directed. 64.00 s & f mild steel screw bolts of 5 to 10 mm diameter of shank ( machine made ) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm and n exc 10cm long complete all as specified and directed. 65.00 m & l for micro concrete ( rendroc rg [ s ] of fosroc ) , mixed with graded coarse aggregate n.exc 12mm in size in propoprtions as per the manufacturers instructions, of any thickness for structural members with and including leak proof form work coated with reabol mould release agent, applying one or more coat of nitozinc primer on the reinforcement steel after cleaning steel surfaces and applying epoxy based nitobond ep for bonding new or old surfaces including providing necessary double scaffolding and removal of the same on completion of the work upto 16th floor complete all as specified and directed. 66.00 m & l for cutting / chipping the spalling concrete surfaces of slabs, beams, columns, fins, facias, parapets & chajjas etc. and trimming, cleaning the surfaces of any thickness to receive guniting / plastering, preparing surfaces and applying a coat of nito bond ar of m / s. fosroc chemicals or equivalent approved bonding agent / epoxy treatment in m / s. sika india pvt. ltd. or m / s. stp ltd. or m / s. choksey chemicals pvt. ltd. or m / s bostik india pvt. ltd. as per manufacturers instructions and providing pressure guniting averaging 25mm thick at a pressure of not less than 6 kg / sq.cm in cement mortar 1:3 duly modifying the mortar with and including suitable bonding agent of m / s. sika india pvt. ltd. or m / s. stp ltd. or m / s. choksey chemicals pvt. ltd. or m / s bostik india pvt. ltd. @ 5% of weight of cement for sides and soffits of slabs, beams, columns, fins, parapets facias & chajjas etc., finishing the top surface even and smooth without using extra cement conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of md land complete all as specified and as directed. 67.00 m & l for cutting / chipping the spalling concrete surfaces of slabs, beams, columns, fins, facias, parapets & chajjas etc. and trimming, cleaning the surfaces of any thickness to receive guniting / plastering, preparing surfaces and applying a coat of nito bond ar of m / s. fosroc chemicals or equivalent approved bonding agent / epoxy treatment in m / s. sika india pvt. ltd. or m / s. stp ltd. or m / s. choksey chemicals pvt. ltd. or m / s bostik india pvt. ltd. as per manufacturers instructions and providing pressure guniting averaging 30mm thick at a pressure of not less than 6 kg / sq.cm in cement mortar 1:3 duly modifying the mortar with and including suitable bonding agent of m / s. sika india pvt. ltd. or m / s. stp ltd. or m / s. choksey chemicals pvt. ltd. or m / s bostik india pvt. ltd. @ 5% of weight of cement for sides and soffits of slabs, beams, columns, fins, parapets facias & chajjas etc., finishing the top surface even and smooth without using extra cement conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of md land complete all as specified and as directed. 68.00 m & l for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings and finishing surfaces even and smooth without using extra cement complete all as specified and directed. 69.00 m & l for rendering 15 mm thick in two coats ( 10mm+5mm each ) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturers instructions and finished the surface even and fair without using extra cement complete all as specified and directed. ( note : wpc shall be measured and paid separately against respective item ) . 70.00 supply only integral water proofing compound ( isi marked ) complete all as specified and directed. 71.00 m & l for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. 72.00 m & l for preparation new external surfaces of wall, chajja, facia etc and applying two coats of water based acrylic weather proof exterior emulsion ( exterior wall finish ) paint over a coat of primer as per manufacturers instruction complete all as specified and directed. 73.00 m & l for preparation old decorated external surfaces of wall, chajja, facia etc by and applying two coats of water based acrylic weather proof exterior emulsion ( exterior wall finish ) paint complete all as specified and directed. 74.00 s & f 5000 litres capacity rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) , hoisted and fixed in position complete as specified in ssr part i and directed. 75.00 s & f 2000 litres capacity rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) , hoisted and fixed in position complete as specified in ssr part i and directed. 76.00 taking up or down 25 or 32 mm bore, steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. 77.00 taking up or down 40 or 50mm bore, steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. 78.00 taking up or down 80mm bore, steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. 79.00 supply, laying, connection and testing, 80mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. 80.00 s & f in repairs, 80 mm bore, gun metal gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. 81.00 s & f 80 mm bore, ball brass valves, high pressure, with polythene float and fly nuts, screwed for iron pipe or brass ferrule complete all as specified and directed. 82.00 supply, laying, connection and testing, 50mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. 83.00 s & f in repairs, 50 mm bore, gun metal gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. 84.00 s & f in repairs, 50 mm bore, ball brass valves, high pressure, with polythene float and fly nuts, screwed for iron pipe or brass ferrule complete all as specified and directed. 85.00 supply, laying, connection and testing, 40mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. 86.00 s & f in repairs, 40 mm bore, gun metal gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. 87.00 s & f in repairs, 40 mm bore, ball brass valves, high pressure, with polythene float and fly nuts, screwed for iron pipe or brass ferrule complete all as specified and directed. 88.00 supply, laying, connection and testing, 25mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. 89.00 s & f in repair 25 mm bore, gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. 90.00 s & f in repairs, 25 mm bore, ball brass valves, high pressure, with polythene float and fly nuts, screwed for iron pipe or brass ferrule complete all as specified and directed. 91.00 s & f in repairs, 20 mm bore, gun metal gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. 92.00 s & f 1000 litres capacity rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) , hoisted and fixed in position as specified in ssr part i and directed. 93.00 s & f rolled mild steel in plates ( plain or chequered ) channels fo grade fe 410 w ( gde e 250 ) quality a, square cut or notched, forming holes, with riveted, bolted or welded attachmentcomplete all as speicfied and directed. 94.00 s & f mild steel screw bolts of 16 to 20 mm diameter of shank ( machine made ) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm and n exc 10cm long complete all as specified and directed. 95.00 m & l for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to fe.290.gde e 165 ( brackets over 10 kg each to be measured under structural steel ) complete all as specified and directed. 96.00 m & l for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed. 97.00 m & l for preparation & cleaning of old polished wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying one or more coat of french polish complete all as specified and directed. 98.00 s & f 3mm thick, plain / designed ( as approved ) , coloured, aluminium composite sheet as in wall cladding / roofing / paneling etc including necessary frame work and fittings and fixtures as per the manufacturers instructions complete all as specified and directed. ( note: work shall be carried out upto 3rd floor height and cost of necessary provisions for the same shall deem to be included in the unit quoted rate ) ...

Sainik School - Andhra Pradesh

29190791 supply of general paint & white wash items for the year 2021 22 to sainik school korukonda, 1 emulsion white (exterior) ltrs asian 2 gold paint (artist) ltrs asian 3 paint aluminium ltrs asian 4 paint black ltrs asian 5 paint blue (oxford blue) ltrs asian 6 paint golden brown ltrs asian 7 paint green ltrs asian 8 paint grey ltrs asian 9 paint ivory ltrs asian 10 paint maroon ltrs asian 11 paint red ltrs asian 12 paint white ltrs asian 14 paint yellow ltrs asian 15 reds oxide ltrs branded 16 thinner ltrs branded 17 thinner d 13 ltrs branded 18 birla white cement kgs branded 19 distemper white kgs asian 20 javan water paper nos. branded 21 putty bag (25 kg) bags latigrate 22 putty blade 4 nos. branded 23 putty blade 6 nos. branded 24 emulsion ming red (epex) kgs asian 25 white cement kgs priya 26 stainer 100 ml branded 27 paint brush 2 nos. branded 28 paint brush 4” nos branded 29 paint brush 5” nos branded 30 iron brush 9” nos branded 31 iron brush 12” nos branded 32 wood primer ltrs branded 33 firose blue ltrs asian...

Sainik School - Andhra Pradesh

29177194 supply of fresh vegetables & fresh fruits, dry ration, general paint & white wash items, general cleaning & chemical items, laundry washing chemical material, mixed cattle feed (mash) and other store items ....

Dr. Y.S.R Horticultural University - Andhra Pradesh

28592981 providing agriculture labour on work contract basis to the horticulture sperations and other related works available 1 preparation of seed/nursery beds and raised beds (1m x 5m) 2 preparation of basins to guava,mango & cocont 3 digging of pits and planting (40m x 40m x400m) 4 sowing of seeds/bulbs/tubers and transplanting of seedlings. 5 irrigation to main field 6 spraying of pesticides and micronutrients (mango, banana and papaya) 7 manual weeding in basin of papaya 8 digging and earthing up in papaya, banana and other crops 9 formation of ridges and furrows and irrigation channels (turmeric, nursery) 10 spreading of mulching sheet.(papaya, cucurbit & vegetables) 11 assistance to tractor driver during leveling and tillering 12 preparation of potting mixture with soil, fym and nutrients along with filling polythene bags. (6”x8’’) 13 mixing and spreading of manures and fertilizers on raised beds. 14 cutting of stakes and staking of plants (banana) 15 harvesting of vegetables, flowers and fruits 16 digging and separation of rhizomes, bulbs, corms, tubers and other crops 17 pruning of trees – mango, guava and acid lime etc. 18 spreading of drip laterals /rolling / drip rectification for horticultural crops 19 drenching of fungicides/nutrients to grafts/ seedlings etc. 20 application and incorporation of fym/fertilizers. 21 general cleaning of roads, bunds, channels, thorny bushes and removal of tall grown weeds. 22 removal of dried/pruned tree branches/other stubbles from fields 23 watering to all nursery plants/seedlings/other crops 24 sweeping labs/office and watering and cleaning in garden (women) 25 weeding in polythene bags in nursery & other experiments 26 pruning and cleaning of hedge 27 ploughing operation in field with office tractor engaging tractor driver. 28 assistance for lab work / office work 29 growth data recording of fruit crops and fruit analysis in lab 30 day and night watch and ward 31 harvesting of turmeric rhizomes 32 lifting and fixing of submersible motor 33 a.lime/ mango seedlings etc lifting in primary nursery, pruning and transplanting in polybag 34 collection of scion stick in mango 35 top cutting of the mango grafts after survival 36 lifting and packing of a. lime/sweet orange with gunny bits 37 grafting with scion on rootstock in mango 38 ploughing with country plough with bullock cart 39 air layering in guava 40 ground layering in guava 41 bagging operation for guava/ mango fruits 42 miscellaneous farm works with man/women. 43 ornamental plant cuttings preparation and planting in poly bags 44 white wash to office building & others 45 clearing & harvesting of coconut produce 46 staking of plants in cucumber & tomato 47 ploughing with tractor on hired basis 48 acid lime seed extraction charges 49 application of bordeaux paste to acid lime & other fruit crops ...

Dr. Y.S.R Horticultural University - Andhra Pradesh

27569372 providing agriculture labour on work done on work contract basis price schedule 1 preparation of seed/nursery beds and raised beds (1m x 5m) 2 preparation of basins to guava,mango & cocont 3 digging of pits and planting (40m x 40m x400m) 4 sowing of seeds/bulbs/tubers and transplanting of seedlings. 5 irrigation to main field 6 spraying of pesticides and micronutrients (mango, banana and papaya) 7 manual weeding in basin of papaya 8 digging and earthing up in papaya, banana and other crops 9 formation of ridges and furrows and irrigation channels (turmeric, nursery) 10 spreading of mulching sheet.(papaya, cucurbit & vegetables) 11 assistance to tractor driver during leveling and tillering 12 preparation of potting mixture with soil, fym and nutrients along with filling polythene bags. (6”x8’’) 13 mixing and spreading of manures and fertilizers on raised beds. 14 cutting of stakes and staking of plants (banana) 15 harvesting of vegetables, flowers and fruits 16 digging and separation of rhizomes, bulbs, corms, tubers and other crops 17 pruning of trees – mango, guava and acid lime etc. 18 spreading of drip laterals /rolling / drip rectification for horticultural crops 19 drenching of fungicides/nutrients to grafts/ seedlings etc. 20 application and incorporation of fym/fertilizers. 21 general cleaning of roads, bunds, channels, thorny bushes and removal of tall grown weeds. 22 removal of dried/pruned tree branches/other stubbles from fields 23 watering to all nursery plants/seedlings/other crops 24 sweeping labs/office and watering and cleaning in garden (women) 25 weeding in polythene bags in nursery & other experiments 26 pruning and cleaning of hedge 27 ploughing operation in field with office tractor engaging tractor driver. 28 assistance for lab work / office work 29 growth data recording of fruit crops and fruit analysis in lab 30 day and night watch and ward 31 harvesting of turmeric rhizomes 32 digging of the trench and filling the trench (with jcb) 33 lifting and fixing of submersible motor 34 a.lime/ mango seedlings etc lifting in primary nursery, pruning and transplanting in poly bag 35 collection of scion stick in mango 36 top cutting of the mango grafts after survival 37 lifting and packing of a. lime/sweet orange with gunny bits 38 grafting with scion on rootstock in mango 39 ploughing with country plough with bullock cart 40 air layering in guava 41 ground layering in guava 42 bagging operation for guava/ mango fruits 43 miscellaneous farm works with man/women. 44 ornamental plant cuttings preparation and planting in poly bags 45 supply of red earth with tractor load (including loading & un loading) 46 supply of fym with transport charges (including loading & un loading) 47 white wash to office building & others 48 clearing & harvesting of coconut produce 49 staking of plants in cucumber & tomato 50 ploughing with tractor on hired basis 51 providing light/heavy vehicle driver with driving license 52 acid lime seed extraction charges 53 application of bordeaux paste to acid lime & other fruit crops ...

Endowment Department - Andhra Pradesh

27388858 supply of water supply and sanitary materials ( pws ) for the financial year 2021 2022 to sri venkateswara swamy vari deavasthanam, dwaraka tirumala 15 x 50mm g i nipples b class 15x100mm g i nipples b class 20x50mm g i nipples b class 20x100mm g i nipples b class 25x50mm g i nipples b class 25x100 mm length g i nipples b class 40x150mm g i nipples b class 40x200mm g i nipples b class 50x150mm g i nipples b class 50x200mm g i nipples b class 15mm gm ball valve 20mm gm ball valve 25mm gm ball valve 15mm gm gate valve 20mm gm gate valve 25mm gm gate valve 40mm gm gate valve 50mm gm gate valve 75mm gm gate valve 15mm brass bibcock 15mm cp lift cock 15mm cp push taps 15 cp angle valve 15mm cp pillar cock 15mm gi dummies 20mm gi dummies 25mm gi dummies 40mm gi dummies 50mm gi dummies 15mm nylon connectors 32mm wash basin waste pipe 32mm wash basin waste plug 15mm iron clamps 20mm iron clamps 25mm iron clamps 40mm iron clamps 50mm iron clamps 75mm ci flange sets 50mm ci flange sets 75mm ci non return valve rock bolt set 50mm brass foot valve 90mm pvc pipe ( 20feet ) 90mm pvc elbow 90mm pvc socket 90mm pvc tee 110mm pvc swr pipe ( 10feet ) 500mm orissa pan 125mm c p gratings 15mm c p long body taps 15mm c p short body taps 15mm c p shower 15x225mm c p shower rods 15mm c p plates 15 x 50mm c p x nippal 250mm x1400mm wash basin ( white ) ewc flesh tank ( white ) wash basin consield brackets ewc seat covers ( white ) 450mm x150mm wash basin ( white ) shallack bottle anabond thread roll hacksaw blades 75mm gm gate valve 75mm gi long bends 20mm conoflex hose pipe 25mm conoflex hose pipe 75mm g i pipe b class 50mm upvc pipe 50mm upvc sockets 50mm upvc elbows 50mm upvc fapt 50mm upvc mapt 50mm upvc tee 50mm x 75mm upvc reducer bt 75mm upvc pipe 75mm upvc sockets 75mm upvc elbows 75mm upvc fapt 75mm upvc mapt 75mm upvc tee 75mmx 25mm upvc reducer bt 32mm upvc pipe 32mm upvc sockets 32mm upvc elbows 32mmupvc fapt 32mm upvc mapt 32mm upvc tee 32mmx 25mm upvc reducer bt 32mm upvc union 32mm upvc ball valve 25mm upvc pipe 25mm upvc sockets 25mm upvc elbows 25mm upvc fapt 25mm upvc mapt 25mm upvc tee 25mm x 20mm upvc reducer bt 20mm upvc pipe 20mm upvc sockets 20mm upvc elbows 20mmupvc fapt 20mm upvc mapt 20mm upvc tee 20mm x 15mm upvc reducerbt 15mm upvc pipe 15mm upvc sockets 15mm upvc elbows 15mm upvc fapt 15mm upvc mapt 15mm upvc tee 15mm upvc union 20mm upvc union 25mm upvc union 75mm upvc union 50mm upvc union 15mm upvc ball valve 20mm upvc ball valve 25mm upvc ball valve 75mm upvc ball valve 50mm upvc ball valve upvc gum 50mm cpvc pipe 50mm cpvc sockets 50mm cpvc elbows 50mm cpvc fapt 50mm cpvc mapt 50mm cpvc tee 50mm x 75mm cpvc bt reducer 75mm cpvc pipe 75mm cpvc sockets 75mm cpvc elbows 75mm cpvc fapt 75mm cpvc mapt 75mm cpvc tee 75mmx 25mm cpvc bt reducer 32mm cpvc pipe 32mm cpvc sockets 32mm cpvc elbows 32mm cpvc fapt 32mm cpvc mapt 32mm cpvc tee 32mmx 25mm cpvc bt reducer 25mm cpvc pipe 25mm cpvc sockets 25mm cpvc elbows 25mm cpvc fapt 25mm cpvc mapt 25mm cpvc tee 25mm x 20mm cpvc bt reducer 20mm cpvc pipe 20mm cpvc sockets 20mm cpvc elbows 20mm cpvc fapt 20mm cpvc mapt 20mm cpvc tee 20mm x 15mm cpvc bt reducer 20mm cpvc union 25mm cpvc union 75mm cpvc union 50mm cpvc union 15mm cpvc ball valve 20mm cpvc ball valve 25mm cpvc ball valve 75mm cpvc ball valve 50mm cpvc ball valve cpvc gum 110 mm hdpe pipe 90 mm hdpe pipe 63 mm hdpe pipe 110 mm hdpe tees 110 mm hdpe elbows 110 mm hdpe colors 110 mm hdpe end cap 110 mm x 90 mm hdpe reducer tee 90 mm hdpe tees 90 mm hdpe elbows 90 mm hdpe colors 90 mm hdpe end cap 90 mm x63 mm hdpe reducertee 63 mm hdpe tees 63 mm hdpe elbows 63 mm hdpe colors 63 mm hdpe end cap 75mm x 50mm pvc reducer 50mm pvc pipe 6kgf ( 20 feet ) 50mm pvc elbows 50mm pvc couplings 50mm pvc tees 50mm pvc ball valve 50mm x 75mm pvc reducer 75mm pvc pipe 6kgf ( 20 feet length ) 75mm pvc elbow 75mm pvc couplings 75mm pvc tees 75mm pvc ball valve 75mmx 32mm pvc reducer 32mm pvc pipe ( 20 feet length ) 32mm pvc elbow 32mm pvc coupling 32mm pvc tee 32mm pvc ball valve 32mm x 25mm pvc reducer 25mm pvc pipe 6 kgf ( 20 feet length ) 25mm pvc tee 25mm pvc elbow 25mm pvc coupling 25mm pvc ball valve 25mm x 20mm pvc reducer 32mm x 25mm upvc bt elbow 25mm x 20mm upvc bt elbow 20mm x 15mm upvc bt elbow 25mm x 15mm cpvc bt elbow 20mm x 15mm cpvc bt elbow 110mm ms flange 90mm ms flange 110mm pvc pipe 6.0 kgf 110mm pvc elbow 110mm pvc long bend 110 x 90mm pvc reducer 110mm pvc tee 90mm pvc pipe 6.0kgf 90mm pvc elbow 90mm pvc long bend 90mm pvc socket 90mm x 63mm pvc reducer 90mm pvc tee 110mm pvc socket 15mm cpvc threded dummy 20mm cpvc threded dummy 25mm cpvc threded dummy health faucets urinal waste pipes urinal cocks westren commodes 15mm gm ball cocks 20mm gm ball cocks 25mm gm ball cocks 75mm gm ball cocks 50mm gm ball cocks flush tank ball cock sets 20mm upvc dummy 25mm upvc dummy 75mm upvc dummy 50mm upvc dummy 50mm cpvc dummy 75mm cpvc dummy 32mm cpvc dummy 15mm gi elbow 50mm u p v c elbow 550mm x 1450mm ss shrink 15mm x300 mm g i nippal 75mm pvc air valve 400mm pvc long bends 400mm pvc long elbow 75mm cpvc m t a 75mm cpvc f t a 75mm cpvc fta 62mm pvc fta 75mm cpvc elbow 75mm pvc mta 75mm x 50mm cpvc bush 32 mm pvc fta 25mm x 15mm cpvc bt reducer pvc mta 65 mm pvc dummy 100mm gi s clamps 75mm pvc dummy thread 20mm gm ball cock 32 mm dummy thread 15mm gm ball cock 32 mm pvc plain dummy 1 hp mono block motor 25mm pvc plain dummy 20mm pvc plain dummy 75mm gm ball cock 32 mm gm gate valve 150mm x 100mm pvc bush 65mm upvc tee 75mm gi slice valve 65mm upvc fta 50mm gi air valve 25mm cpvc tank nipple 50mm cpvc elbow 200mm hdpe neck collar 200mm hdpe planza 75mm x 32mm cpvc bush 50mm x 32mm cpvc bush 25mm x 20mm cpvc bush 20mm cpvc dummy 32mm x 32mm cpvc btl 32 mm x 32mm cpvc btr 25mm x 25mm cpvc btl 50mm x 75mm upvc bush 50mm x 75mm upvc bush 75mm cpvc pipe 400mm pvc pipe solar hot water panels 400mm hdpe planza 4 inch hdpe planza 50mm hdpe planza 50mm hdpe planza dummy 25mm upvc tank nipples 25mm upvc dummys 20mm inch upvc dummys 75mm upvc dummys 50mm upvc dummys 25mm cpvc dummys 20mm cpvc dummys 32mm cpvc dummys 75mm cpvc dummys 50mm cpvc dummys 25mm gm ball cocks and balls 20mm gm ball cocks and balls 15mm gm ball cocks and balls 50mm gm ball cocks and balls hot water geyser connectors 50mm pvc air valves 75mm pvc air valves 15mm urinals push cock 75mm gm ball valve 50mm gm ball valve flush tank ball cock sets...

Municipalities - Andhra Pradesh

26756441 dw & cda schemes execution of works under swachchatha action plan for minor repairs, drinking water provision, toilets renovation, white wash, etc. at bala sadhan narasinga rao peta 32nd ward gudur municipality spsr nellore....

South Central Railway - Andhra Pradesh

26142720 supply of , supply r.c.c. lid cover of size 450 x 450 x 4.5 mm along with white wash suitable for earth pit chamber of size 450 x 450 x 50 mm....

Military Engineer Services - Andhra Pradesh

24777634 repairs and upkeeping of water supply installations/fire fighting installations including chlorination panels at naval base area under age e/m no . 1 of ge ( u ii ) visakhapatnam , material and labour for maintaining of potable /fresh water to achieve chlorination level by keeping concentrated efforts as per standard water quality specifications of maintaining ppm , ph , tds levels , by checking time to time with standard testing equipments/lab test items if any daily before pumping of water to users from sump/ohts to building oh tanks through raising mains etc . by adding chlorination granuals , chlorine gas etc . as required for disinfection of water as per standard at site as under : , ( a ) ppm at sump level to pumping water to building oh tank 2ppm , ( b ) ph value 6 . 5 to 8 . 5 , tds 300ppm ( c ) ensuring water is to be free from e . coli and thermotolerant coliform bacteria and it shall not be detectable in any 100ml of sample water . , notes : the item rate is inclusive of following : , ( a ) the contrator or his rep is responsible for maintaining quality of drinking water as specified above and to adopt latest standard of water treatment for providing specified potable water . ( b ) contractor or his rep has to attend daily at all pump houses once in a day to check all the water parameters and sign in the register being maintained with pump house staff . ( c ) register should be maintained daily and daily record of the same should be endorsed from users/mes rep at pump house , concerned engineer in charge as well as concerned medical team of respective unit daily . ( d ) lab test shall be carried out once in a month from locally available govt approved lab for ( i ) ppm , ( ii ) tds , ( iii ) ph value and e coil or thermotolerent coliform bacteria . test report be rendered and a record of the same to be submitted to department once in a month or whenever required or directed by the users and department depend upon the situation/quality of water . , ( e ) the rate quoted is deemed to be inclusive of adding required chemicals like soda ash etc . , to maintain ph value and tds as and when required . , ( e ) required quantity of chlorine gas/ chlorine granuals/ bleaching powder required to be used at pump houses regularly and superchlorination to be done and the same shall be measured and paid seperately under relevant items of schedule . the amount/quantity of mixing chemicals , gas etc . , would be vary as per the quality of receiving water from time to time to bring the required ppm once checked before pumping the water from sump to oht of user building . the necessary mixing up of granuals/bleaching powder for maintaining standard water and for superchlorination the existing staff/ manpower at pump houses shall be utilized if necessary . , the above specified job shall be carried out at each pump house as under : , ( a ) nausenabaugh main pump house ( 02 places ) , ( b ) mes key pers ph , nsb , ( c ) ins circars ( d ) naval park & amzari park , ( e ) ins sathavahana , ( f ) mwc , ( g ) smhq , ( h ) ins virbahu , ( j ) ce navy office ph , ( k ) ncb , ( l ) hfdf pump house , ( m ) navy house ( n ) mmt ( e ) 14 nos . , m&l for cleaning of underground/ semi underground fresh water sump of 2 . 00 lakhs gallons capacity by pumping out with dewatering pump the accumulated water up to the bottom surface and removing the complete silt sediment sludge from the sumps and depositiing and levelling as directed , cleaning the walls , ceiling & floor of the sump completely using high pressure water jet to dislodge all the mud , dirt algaue , fungus and layers of calcinations , vacuum cleaning to remove dislodged waste and cleaning with the bleaching powder after scrapping the walls and bottom of the sump completely using wire brush without disturbing the water supply to the area including applying one coat of white wash to entire sump externally as well as internally and writing details like cleaning date / due date/ sump capacity with synthetic enamel paint complete all as directed . , all as per item no . 2 above but ug/semi ug sump of capacity 1 . 60 lakhs gallons , all as per item no . 2 above but ug/semi ug sump of capacity 1 . 50 lakhs gallons , all as per item no . 2 above but oh tank of capacity 1 . 25 lakhs gallons , all as per item no . 2 above but oh tank of capacity 1 . 00 lakhs gallons , all as per item no . 2 above but ug/semi ug sump of capacity 0 . 50/0 . 60 lakhs gallons , all as per item no . 2 above but ug/semi ug sump 0 . 20 to 0 . 40 lakhs gallons , all as per item no . 2 above but of static water tank of capacity 0 . 25 to 0 . 50 lakh gallons , m&l for maintenance of 105 bhp diesel driven pump for b check as per recomendation of manufacturers including replacement of necessary filters , accessories like fuel filter with ring , air filter and ring , super bypass filter element , o ring seal , oil filter and engine oil complete all as specified and directed by engr in charge . , all as per item no 10 above but 91 bhp capacity diesel engine driven pump set , supply and replace copper battery terminals all as directed by engr in charge . , supply only for top up engine oil 15w40 or as per manufacturers recommendations . make: servo/ volvoline/hpcl , supply , install , testing and commissioning of 12 v , 180 ah inbuilt battery charger type maintenance free battery including terminal clamps , copper lead of suitable size/ length , battery stand including taking down unserviceable one from the dg set complete all as directed . , m&l for complete engine overhauling of dd pump of 82 . 5 bhp capacity by replacing unserviceable spare parts like pistons , liners , valves , fuel injector sleeves , head gasket kit including fuel pump and fuel injector repairs and calibration , heat exchanger descaling and complete bcheck of the dd pump all as directed by engr in charge , all as per item no 15 above but upto 60 bhp capacity diesel engine driven pump set , supply and replacement of fire hydrant landing valve gun metal , type b ( double head outlet ) of 63 mm bore conforming to is 5290 complete all as specified and directed . , supply and replacement of fire hydrant landing valve gun metal , type a ( single head outlet ) of 63 mm bore conforming to is 5290 complete all as specified and directed . , supply and replacement of fire brigade inlet connection 4 way including with accessories suitable for 150 mm dia pipe complete all as specified and directed . , supply and replacement 63 mm dia canvas pipe 15 metre long hose pipe confirming to is 636 complete with male and female coupling and drum made out of ms sheet confirming to is 903 complete all as specified and directed , repair/ servicing of any type water level indicator by replacing wornout central movement plate , counter weight , centre diving wheels etc . , ncesaary required parts at site for fully operational , replacement of front glass with pvc/rubber gasket and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed . , supply & replacement of water level indicator , 36 dia as per is and including numbering with radium stickering , heavy duty float , counter weight , heavy duty driving gear nylon wire fitted in all in gi housing , cutting the rcc slab and making good the slab , painting the exposed surface with two coats of synthetic enamel over a coat of red oxide primer complete all as specified and directed by engr in charge . note: make of water level indicator shall be got approved by ge before procurement . , supply only calcium based , high strength chlorination chemical for disinfectant , in granual form for water treatment in factory sealed non returnable hdpe containers ( 40 to 50 kg each ) having chlorine concentration level of...

Sainik School - Andhra Pradesh

24622816 supply of fresh vegetables & fresh fruits, dry provisions, laundry washing chemical material, mixed cattle feed, paint & white wash items, general cleaning & chemical items, stitched uniforms for cadets & staff, electrical items, supply of charcoal, general carpentry, re winding of fans and other store items...

Military Engineer Services - Andhra Pradesh

24577107 manning and operation to fire fighting system , fresh water pump house at raqas pump house and p 5 pump house dega vihar pump house and allied e/m work at ins dega under age e/m no . ii of ge ( utility ii ) visakhapatnam , manning , operation , maintenance of fire fighting pump house and fresh water pump hiouse ( 350 ph ) , consisting of fire main pump sets , diesel engine driven pumpset , jockey pumpset , fresh water pumpsets , automation panel , control panels , connected pipe line and valves etc . , including 150 mm dia ms/dii water pipe line with connected valves and various size of ms/di/gi pipe line network for smooth and trouble free operation round the clock in three shifts per day of 08 hours each including sundays and holidays complete all as specified and directed by engineer in charge , man power: one skilled operator ( fgm ) per shift of 08 hours in three shifts per day and timings as under . ist shift 0600 hrs to 1400 hrsiind shift 1400 hrs to 2200 hrsiiird shift 2200 hrs to 0600 , manning , operation , maintenance of ins dega ( p 5 ) pump house consisting of 25 hp pumpsets 02 nos , 10 hp pumpsets 02 nos , starter panels , lt panels , automation panel , control panels , connected pipe line and valves etc . , including incoming 150 mm dia di water pipe line with connected valves from nad colony ph to ins dega , various size of ci/ms/di/gi distribution pipe line network for smooth and trouble free operation round the clock in three shifts per day of 08 hours each including sundays and holidays complete all as specified and directed by engineer in charge , man power: one skilled operator ( fgm ) and one valve man per shift of 08 hours in three shifts per day and timings as under . ist shift 0600 hrs to 1400 hrsiind shift 1400 hrs to 2200 hrsiiird shift 2200 hrs to 0600 , manning , operation , maintenance of watch tower no . 7 pump house and raqas pump house consisting of 20 hp pumpsets 02 nos , 15 hp pumpsets 02 nos , 1 . 5 hp pumpsets 02 nos , submersible pump 7 . 5 hp 01 no , starter panels , lt panels and valves etc . , including incoming water pipe line with connected valves , various size of ci/ms/di distribution pipe line network for smooth and trouble free operation round the clock in three shifts per day of 08 hours each including sundays and holidays complete all as specified and directed by engineer in charge , man power: one skilled operator ( fgm ) per shift of 08 hours in three shifts per day and timings as under . ist shift 0600 hrs to 1400 hrsiind shift 1400 hrs to 2200 hrsiiird shift 2200 hrs to 0600 , manning , operation , maintenance of dega vihar pump house consisting of 12 . 5 hp pumpsets 02 nos , 30 kva dg sets 01 no , starter panels , lt panels and valves etc . , including incoming water pipe line with connected valves , various size of ci/ms/di/gi distribution pipe line network for smooth and trouble free operation round the clock in three shifts per day of 08 hours each including sundays and holidays complete all as specified and directed by engineer in charge , man power: one skilled operator ( fgm ) per shift of 08 hours in three shifts per day and timings as under . ist shift 0600 hrs to 1400 hrsiind shift 1400 hrs to 2200 hrsiiird shift 2200 hrs to 0600 note: manning covered under si no . 4 of boq shall commence from 12 nov 2020 , note for si item no . 1 to 4 : ( i ) the quoted rate is deemed to inclusive of cleaning of plant surrounding area , plant room daily . ( ii ) the contractor shall ensure proper functioning of the plants installed at both the locations . ( iii ) the rate quoted shall be inclusive of carring out minor repairs like replacement of gland packing , greasing of bearings , rectifying leakages etc including consumables . ( iv ) the operator shall maintain proper log sheet for running of pump sets . ( v ) the operator shall maintain proper record of the running of the pump sets and keep the installations premises clean and tidy . ( vi ) the operator shall also ensure the proper functioning of the fire hydrants and will arrest any minor leakages found in the system . ( vii ) carrying out a check daily for dg sets as per manufacturer manual . , ( viii ) fiiling distilled water/ batttery electrolyte and charging of batteries as and when required . ( ix ) the operator shall ensure trail run and be alert to run the dg sset within 5 minutes of supply failure in case of manual operation/ failure of auto mains . ( x ) the rate quoted shall be inclusive of carring out minor repairs like replacement of gland packing , greasing of bearings , rectifying leakages etc including consumables . ( xi ) the operator shall maintain proper log sheet for running of dg sets . ( xii ) disel shall be issued by department as and when required and transportation shall be deemed to be included in the quoted rate . , note for si item no . 1 to 4 : ( i ) before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of ge duly recomended by engineer in charge . , supply only calcium based , high strength chlorination chemical for disinfectant , in granual form for water treatment in factory sealed non returnable hdpe containers ( 40 to 50 kg each ) having chlorine concentration level of 70% complete all as specified and as directed . make: rayalaseema/ declibac or its equivalent make as approved by e in cs branch and approved by ge . , m&l for maintenance of diesel engine connected with dg set 30 kva for b check as per recomendation of manufacturers instructions including replacement of filters , accessories like fuel filter with ring , air filter and ring , super bypass filter element , o ring seal , oil filter and engine oil complete all as specified and directed by engr in charge . , m&l for cleaning of underground/semi underground fresh water sump of 0 . 50 lakhs gallons capacity by pumping out the accumulated water up to the bottom surface and removing the complete silt sediment sludge from the sumps and depositiing and levelling as directed and cleaning with the bleaching powder after scrapping the walls and bottom of the sump completely using wire brush without disturbing the water supply to the area including applying one coat of white wash to entire sump externally as well as internally and writing details like cleaning date / due date/ sump capacity with synthetic enamel paint complete all as directed . , all as per sl . item no . 7 above but 0 . 30 lakh gallons , all as per sl . item no . 7 above but 0 . 20 lakh gallons , all as per sl . item no . 7 above but 0 . 10 lakh gallons , m&l for cleaning of over head tank of 0 . 50 lakhs gallons capacity at 18m staging by cleaning out the accumulated water in the bottom and removing the complete silt from the tank and depositing and levelling as directed and cleaning with the bleaching powder , after scrapping the walls and bottom of the tank by using wire brush completely without disturbing the water supply to the area , and applying one coat of white wash inside oh tank and writing details like cleaning/ due date/ tank capacity with synthetic enamel paint on bottom wall complete all as directed . , all as per sl . item no . 11 above but 0 . 30 lakh gallons , m & l for carrying out physical , chemical & bacteriological analysis all as per is 10500:2012 for drinking water sample of the fresh water pump house at various locations from govt authorised laboratory all as per cpcb norms complete all as directed by engineer in charge . note : the rate quoted is deemed to be inclusive of collecting of water samples in sealed pvc container , m & l for jungle cleaning by cutting an...

Military Engineer Services - Andhra Pradesh

24530378 manning , operation and maintenance of pump sets/ dg sets , lt panels of yarada , middle , arsr pump houses , water distribution network and stp at d sector incl mainte of connected e/m and misc works under age e/m no . ii of ge ( utility ii ) visakhapatnam , manning , operation and maintenance of multistage pumpsets/ submersible/ centrifugal / jet pumpsets , 62 . 5 kva dg set and connected electrical panels at middle pump house & yarada village pump house for smooth and trouble free operation in one shift per day of 08 hours each including operation of control valves all as specified and directed by engineer in charge . , manpower : one semi skilled operator for general shift shift timings: 0900 hrs to 1700 hrs , note : the rate quoted deemed to be inclusive of ( a ) rectifying minor defects such as arresting of pipeline leakage , greasing of pumps , gland packing , fuse wire , repairs to foot valve etc . , whenever required . ( b ) keeping the installations area neat and clean by grass cutting and removing the debris in and around premises . ( b ) keeping daily record of all pumps running status all as specified and directed . ( d ) the no of working hrs at village pump house and middle pump house shall be as directed by engr in charge . , manning for operation and maintenance of sewage treatment plant at d sector area , sequential batch reactor type , of capacity 460 cum/day of make: m/s acme enviro solutions private ltd consisting of bar screen cum oil & grease separation chamber , equalisation tank , eco r reactor , chlorine contact cum treated water tank , sludge drying beds , sewage transfer pumps , air blower , sludge transfer pump , treated water transfer pump , arboriculture pumps , dg set of capacity 62 . 5 kva and connected valves & electric panels etc . , round the clock in manual mode/ programmable logic controlled auto mode for treating raw sewage all as per manufacturers instructions/ recommendations for smooth and trouble free operation in three shifts including operation of dg set of 62 . 5 kva during power failure at d sector stp all as specified and directed by engineer in charge . , manpower : one skilled operator and one helper per shift of 08 hrs for first two shifts and one skilled operator for third shift including sundays and holidays all as directed by engineer in charge . shift timings: i st shift 0600 hrs to 1400 hrsii nd shift 1400 hrs to 2200 hrsiii rd shift 2200 hrs to 0600 hrstotal manpower: 03 skilled + 02 helper per day , note : the rate quoted deemed to be inclusive of ( a ) keeping the installations area neat and clean by grass cutting and removing the debris in and around premises . ( b ) keeping daily record of all pumps running status all as specified and directed . ( c ) rectifying minor defects such as arresting of pipeline leakage , greasing of pumps , gland packing , fuse wire , repairs to foot valve etc whenever required . ( d ) carrying out a check of dg set daily as per manufacturers manual . ( e ) replacing of distilled water/battery electrolyte and charging of batteries of dg sets as and when required . ( f ) the installation will be handed over in operating state on the commencement of contract though work order . , ( g ) the operator shall ensure by trial run and be alert to run the dg set within 5 minutes of supply failure . ( h ) diesel shall be issued by department as and when required . contractor shall have to intimate minimum 03 days in advance for issue of diesel . ( j ) the quoted rate is inclusive collecting and transportation of diesel from age e/m store yard to work site . ( k ) cleaning of bar screen cum oil & grease separation chamber twice daily all as directed . ( l ) cleaning/slaking of sludge drying beds every week all as directed . ( m ) operation of arboricuture pumpsets including control for supplying treated water as and when required . ( n ) during the operation of the plant , the mlss ( mixed liquid suspended solids ) shall be maintained not less than 4000 mg/ltr in eco r tank . , man power ( skilled ) employed shall have minimum 02 years work experience in operation of stp . , manning for maintenance and operation of fresh water pump house consisting of various types of pump sets , chlorination system , lt panels , water sumps of arsr pump house at ts dolphin hills for pumping water to arsr complex , other bldgs and other areas , for smooth and trouble free operation in general shifts of 08 hrs per day including sundays and holidays complete all specified and directed by engineer in charge , manpower : one semi skilled operator for general shift shift timings: 0900 hrs to 1700 hrs , manning for operation and maintenance of distribution control valves at arsr complex , other bldgs and distribution of water to different bldgs/ locations at arsr complex in general shifts of 08 hours each per day including sundays and holidays complete all specified and directed by engineer in charge , manpower : one valve man ( semi skilled ) operator per shift shift timings: 0900 hrs to 1700 hrs , note : the rate quoted deemed to be inclusive of ( a ) the contractor is fully responsible for the smooth and trouble free operation of pumpsets and timely controlling valves and distribution of water in the areas mentioned above . ( b ) the operator shall check and monitor the pumping timings of water from booster pump house ( main ) , nsb to ts dolphin hills/ arsr pump house . ( c ) in case of any abnormal delay in incoming pumping , the operator shall inform the matter to concerned je or age e/m for further action . ( a ) keeping the installations area neat and clean by grass cutting and removing the debris in and around premises . ( b ) keeping daily record of all pumps running status all as specified and directed . , material and labour for cleaning of rcc equilisation tank of approx size 5 . 5 m x 8 . 0 m x 5 . 5 m of stp by bailing out the accumulated raw water at the bottom and removing the complete silt/sludge/dirt from the tank and dispositing away exc 1 . 5 km and n . exc 5 . 0 km from site as directed , scrapping the tank inner walls and bottom with wire brush and cleaning the tank inner walls and bottom with the bleaching powder slurry completely including applying one coat of white wash to entire tank externally complete all as directed by engineer in charge . note: ( a ) the rate deemed to be inclusive of t&p and transportation required for disposal of sludge/dirt away from the site . ( b ) the cleaning of tank shall be performed once in two months month as per manufacturers recommendations . , all as per sl item no . 5 above but for treated water tank of size 8 . 0 m x 6 . 0 m x 3 . 5 m , m & l for carrying out chemical analysis ( bod/cod ) test of treated sewer water of stp from govt authorised laboratory all as per cpcb norms complete all as directed by engineer in charge . note : the rate quoted is deemed to be inclusive of testing and collection of water samples in sealed pvc container at stps . , removing old filter media complete of size 1/8 to 1/16 , 1/16 to 1/32 inch sizes complete in layers of sludge drying beds of size 4 x 2 . 50 x 1 . 4 m , scraping the internal surfaces of sludge drying beds with wire brush , and cleaning with bleaching powder slurry , cleaning with fresh water including applying one coat of white wash on external surface of sludge drying bed and re filling up with new filter media in layers all as per manufacturers recommendations / existing including testing and commissioning etc . , complete all as directed . note: new filter media will be measured and paid separately under relevant item of boq , supply only aggregate filter media for stp ( as per existing ) complete of size 1/8 to 1/16 , 1/16 to 1/32 inch size compl...

Military Engineer Services - Andhra Pradesh

24429575 manning and operation to fire fighting system , fresh water pump house at raqas pump house and p 5 pump house dega vihar pump house and allied e/m work at ins dega under age e/m no . ii of ge ( utility ii ) visakhapatnam , manning , operation , maintenance of fire fighting pump house and fresh water pump hiouse ( 350 ph ) , fire fighting pump house consisting of fire main pump sets , diesel engine driven pumpset , jocket pumpset , fresh water pumpsets , automation panel , control panels , connected pipe line and valves etc . , including 150 mm dia ms/di water pipe line with connected valves and various size of ms/di/gi pipe line network for smooth and trouble free operation round the clock in three shifts per day of 08 hours each including sundays and holidays complete all as specified and directed by engineer in charge , man power: one skilled operator ( fgm ) per shift of 08 hours in three shifts per day and timings as under . ist shift 0600 hrs to 1400 hrsiind shift 1400 hrs to 2200 hrsiiird shift 2200 hrs to 0600 , manning , operation , maintenance of ins dega ( p 5 ) pump house consisting of 25 hp pumpsets 02 nos , 10 hp pumpsets 02 nos , starter panels , lt panels , automation panel , control panels , connected pipe line and valves etc . , including incoming 150 mm dia di water pipe line with connected valves from nad colony ph to ins dega , various size of ci/ms/di/gi distribution pipe line network for smooth and trouble free operation round the clock in three shifts per day of 08 hours each including sundays and holidays complete all as specified and directed by engineer in charge , man power: one skilled operator ( fgm ) per shift of 08 hours in three shifts per day and timings as under . ist shift 0600 hrs to 1400 hrsiind shift 1400 hrs to 2200 hrsiiird shift 2200 hrs to 0600 , manning , operation , maintenance of watch tower no . 7 pump house and raqas pump house consisting of 20 hp pumpsets 02 nos , 15 hp pumpsets 02 nos , 1 . 5 hp pumpsets 02 nos , submersible pump 7 . 5 hp 01 no , starter panels , lt panels and valves etc . , including incoming water pipe line with connected valves , various size of ci/ms/di distribution pipe line network for smooth and trouble free operation round the clock in three shifts per day of 08 hours each including sundays and holidays complete all as specified and directed by engineer in charge , man power: one skilled operator ( fgm ) per shift of 08 hours in three shifts per day and timings as under . ist shift 0600 hrs to 1400 hrsiind shift 1400 hrs to 2200 hrsiiird shift 2200 hrs to 0600 , manning , operation , maintenance of dega vihar pump house consisting of 12 . 5 hp pumpsets 02 nos , 30 kva dg sets 01 no , starter panels , lt panels and valves etc . , including incoming water pipe line with connected valves , various size of ci/ms/di/gi distribution pipe line network for smooth and trouble free operation round the clock in three shifts per day of 08 hours each including sundays and holidays complete all as specified and directed by engineer in charge , man power: one skilled operator ( fgm ) per shift of 08 hours in three shifts per day and timings as under . ist shift 0600 hrs to 1400 hrsiind shift 1400 hrs to 2200 hrsiiird shift 2200 hrs to 0600 note: manning covered under si no . 4 of boq shall commence from 12 nov 2020 , note for si item no . 1 to 4 : ( i ) the quoted rate is deemed to inclusive of cleaning of plant surrounding area , plant room daily . ( ii ) the contractor shall ensure proper functioning of the plants installed at both the locations . ( iii ) the rate quoted shall be inclusive of carring out minor repairs like replacement of gland packing , greasing of bearings , rectifying leakages etc including consumables . ( iv ) the operator shall maintain proper log sheet for running of pump sets . ( v ) the operator shall maintain proper record of the running of the pump sets and keep the installations premises clean and tidy . ( vi ) the operator shall also ensure the proper functioning of the fire hydrants and will arrest any minor leakages found in the system . ( vii ) carrying out a check daily for dg sets as per manufacturer manual . , ( viii ) fiiling distilled water/ batttery electrolyte and charging of batteries as and when required . ( ix ) the operator shall ensure trail run and be alert to run the dg sset within 5 minutes of supply failure in case of manual operation/ failure of auto mains . ( x ) the rate quoted shall be inclusive of carring out minor repairs like replacement of gland packing , greasing of bearings , rectifying leakages etc including consumables . ( xi ) the operator shall maintain proper log sheet for running of pump sets . ( xii ) the operator shall maintain proper record of the running of the pump sets and keep the installations premises clean and tidy . ( xiii ) disel shall be issued by department as and when required and transportation shall be deemed to be included in the quoted rate . , note for si item no . 1 to 4 : ( i ) before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of ge duly recomended by engineer in charge . , supply only calcium based , high strength chlorination chemical for disinfectant , in granual form for water treatment in factory sealed non returnable hdpe containers ( 40 to 50 kg each ) having chlorine concentration level of 70% complete all as specified and as directed . make: rayalaseema/ declibac or its equivalent make as approved by e in cs branch and approved by ge . , m&l for maintenance of diesel engine connected with dg set 30 kva for b check as per recomendation of manufacturers instructions including replacement of filters , accessories like fuel filter with ring , air filter and ring , super bypass filter element , o ring seal , oil filter and engine oil complete all as specified and directed by engr in charge . , m&l for cleaning of underground/semi underground fresh water sump of 0 . 50 lakhs gallons capacity by pumping out the accumulated water up to the bottom surface and removing the complete silt sediment sludge from the sumps and depositiing and levelling as directed and cleaning with the bleaching powder after scrapping the walls and bottom of the sump completely using wire brush without disturbing the water supply to the area including applying one coat of white wash to entire sump externally as well as internally and writing details like cleaning date / due date/ sump capacity with synthetic enamel paint complete all as directed . , all as per sl . item no . 7 above but 0 . 30 lakh gallons , all as per sl . item no . 7 above but 0 . 20 lakh gallons , all as per sl . item no . 7 above but 0 . 10 lakh gallons , m&l for cleaning of over head tank of 0 . 50 lakhs gallons capacity at 18m staging by cleaning out the accumulated water in the bottom and removing the complete silt from the tank and depositing and levelling as directed and cleaning with the bleaching powder , after scrapping the walls and bottom of the tank by using wire brush completely without disturbing the water supply to the area , and applying one coat of white wash inside oh tank and writing details like cleaning/ due date/ tank capacity with synthetic enamel paint on bottom wall complete all as directed . , all as per sl . item no . 11 above but 0 . 30 lakh gallons , m & l for carrying out physical , chemical & bacteriological analysis all as per is 10500:2012 for drinking water sample of the fresh water pump house at various locations from govt authorised laboratory all as per cpcb norms complete all as directed by engineer in charge...

Military Engineer Services - Andhra Pradesh

24388148 manning , operation of pump houses , dg sets , fire pump houses with connected e/m works at bph i bph ii at nsb and ins eksila area under age e/m no . ii of ge ( utility ii ) visakhapatnam , manning , operation and maintenance of fresh water pump house ( booster pump house i & ii at nsb ) consisting of various types of 250 hp capacity multistage booster pumpsets 4nos , 500 kva dg sets 2 nos , vacuum pumpsets , connected pipe line & valves , chloronome plant , lt panels , water sumps at nausenabaugh for pumping to dolphin hill and other areas , for smooth and trouble free operation round the clock in three shifts a day including sundays and holidays complete all specified and as directed by engineer in charge . , manpower : one skilled fgm and one semi skilled per shift . shift timings: i st shift 0600 hrs to 1400 hrsii nd shift 1400 hrs to 2200 hrsiii rd shift 2200 hrs to 0600 hrs , manning , operation and maintenance of bph i & ii pump houses ( at eksila ) consisting of 50 hp pumpsets 4 nos , 82 . 5 kva dg set 1no , 125 kva dg set 1 no , starter panels , lt panels etc and fire fighting pump house consisting of fire main pumpsets , automation panel , diesel engine driven pumpset , jockey pumpsets and control panels , connected pipeline and valves etc . , at ins eksila including 250 mm dia di water pipe line with connected valves from ins eksila to nausenabaugh complete for smooth and trouble free operation round the clock in three shifts a day including sundays and holidays complete all specified and as directed by engineer in charge . , manpower : one skilled fgm and one semi skilled per shift . shift timings: i st shift 0600 hrs to 1400 hrsii nd shift 1400 hrs to 2200 hrsiii rd shift 2200 hrs to 0600 hrs , note for si item no . 1 & 2 :the rate quoted deemed to be inclusive of ( i ) cleaning the sorroundings of the pumps and greasing periodicaly for smooth functioning of the pumps , keeping daily record of pumpsets running hrs all as specified and directed by engineer in charge . ( ii ) keeping neat and clean of complete installation area by grass cutting and removing the debris in around premises upto 1 . 5 m from installation building . ( iii ) keeping daily record of dg running hrs all as specified and directed by engr in charge . ( iv ) carrying out a check of dg set daily as per manufacturers manual . ( v ) replacing of distilled water/battery electrolyte and charging of batteries as when required . , ( vii ) the operator shall ensure by trial run and be alert to run the dg set within 5 minutes of supply failure in case of manual operation/ failure of auto mains . ( viii ) diesel and engine oil shall be issued by department as and when required as directed by eic . the quoted rate is deemed to be inclusive of transporation of diesel and engine oil from store yard to work site . ( ix ) the operator shall load diesel in the fuel tank , regular checking of engine oil , battery electrolyte and radiator water level and rectifying minor defects such as engine air lock , tightening of loose bolts and nuts etc , which may develop during operation and relative parameters all as specified . , manning , operation and maintenance of control valves of oh tanks at ins eksila and distributing water to otm , in living & dsc accn area of ins eksila complete including opening and controlling of building sluice valves /gate valves for smooth and trouble free water distribution to entire ins eksila area in two shift of each 8 hours per day including sundays and holidays complete all as directed by engineer in charge . , manpower : one semi skilled ( valve man ) per shift . shift timings: i st shift 0600 hrs to 1400 hrsii nd shift 1400 hrs to 2200 hrs , supply only aquafit chlorine 56% 70% ( calcium based granular disinfectant for water treatment , more stable for water treatment than chlorine gas and stronger than bleaching powder and sodium hypochlorite ) in 45 kg drums for maintaining residual chlorine between 1 to 2 ppm at supply end and 0 . 5 ppm at user end complete all as specified and as directed . make: rayalaseema/ declibac or its equivalent make as approved by e in cs branch and approved by ge . , m&l for maintenance of diesel engine connected with dg set 500 kva for b check as per recomendation of manufacturers instructions including replacement of filters , accessories like fuel filter with ring , air filter and ring , super bypass filter element , o ring seal , oil filter and engine oil complete all as specified and directed by engr in charge . , all as per sl item no . 5 above but of dg set of 125 kva , all as per sl item no . 5 above but of dg set of 82 . 5 kva , m&l for cleaning of underground/ semi underground fresh water sump of 3 . 00 lakhs gallons capacity by pumping out the accumulated water up to the bottom surface and removing the complete silt sediment sludge from the sumps and depositiing and levelling as directed and cleaning with the bleaching powder after scrapping the walls and bottom of the sump completely using wire brush without disturbing the water supply to the area including applying one coat of white wash to entire sump externally as well as internally and writing details like cleaning date / due date/ sump capacity with synthetic enamel paint complete all as directed . , all as per sl item no . 8 above but sump of capacity 2 . 50 lakh gallons capacity , all as per sl item no . 8 above but sump of capacity 1 . 00 lakh gallons capacity , all as per sl item no . 8 above but sump of capacity 0 . 30 lakh gallons capacity , all as per sl item no . 8 above but over head tank of capacity 0 . 80 lakhs gallons capacity at 15 metre height , m&l for cleaning of shallow well of size 10 . 5 metre dia , 15 metre deep ( approx ) ( at eksila ) by pumping out the accumulated water up to the bottom surface and removing the complete silt sediment sludge and depositiing and levelling as directed and cleaning with the bleaching powder after scrapping the walls upto bottom completely using wire brush without disturbing the water supply to the area including applying one coat of white wash to entire well internally and applying one coat of synthetic enamel paint for angle iron grid and writing details like cleaning date / due date/ capacity with synthetic enamel paint complete all as directed . , m & l for carrying out physical , chemical & bacteriological analysis all as per is 10500:2012 for drinking water sample of the fresh water pump house at various locations from govt authorised laboratory all as per cpcb norms complete all as directed by engineer in charge . note : the rate quoted is deemed to be inclusive of collecting of water samples in sealed pvc container , m & l for jungle cleaning by cutting and clearing away all grass vegetation , wild growth , sapling , shrubs , brushwoods , under growth roots , cutting of bushes , tree trunk of girth not execeeding 30 cm , cutting of trunk , portion protuding over ground , filling holes and leveling of ground and removing unserviceable materials to a distance n . exe 50m , compelte all as speicified , m&l for painting of pumpsets of 250 hp capacity with a coat of approved synthetic enamel paint including inlet & out let pipe lines complete including preparation of old painted surface and writting mes number all as specified and directed by engineer in charge . , all as per sl item no . 16 above but of capacity 90 to 125 hp , all as per sl item no . 16 above but of capacity 50 hp , all as per sl item no . 16 above but of capacity 20 to 40 hp , all as per sl item no . 16 above but of capacity 2 to 15 hp , m& l for servicing of lt panels of any size by cleaning the panel , bus bar chamber with ctc solution , and welding the door using arc welding and fixing hinges , necessary nut and...

Military Engineer Services - Andhra Pradesh

24263195 repair/ maintenance of water supply distribution system at nirman park , svn key personnal area , meghadrigedda filteration plant and other misc works under age e/m no . i of ge ( utility ii ) visakhapatnam , labour for attending gi pipe line complaints ( break downs ) in buildings upto g+1 floor , terrace and plain area for pipe of size 15 mm to 40 mm dia including cutting and threading of pipes as per site requirement complete all as specified and directed by engr in charge . note: gi pipe shall be measured and paid separately under relevent items . , labour for attending gi pipe line complaints ( break downs ) in buildings upto g+3 floor , terrace and plain area for pipe of size 15 mm to 40 mm dia including cutting and threading of pipes as per site requirement including necessary scaffolding and safety measures complete all as specified and directed by engr in charge . note: gi pipe shall be measured and paid separately under relevent items . , labour for attending gi pipe line complaints ( break downs ) in plain area for pipe of size 50 mm to 80 mm dia including cutting and threading of pipes as per site requirement complete all as specified and directed by engr in charge . note: gi pipe shall be measured and paid separately under relevent items . , labour for attending gi pipe line complaints ( break downs ) in buildings upto fourth storey , terrace and plain area for pipe of size 20 mm to 50 mm dia including cutting and threading of pipes as per site requirement complete all as specified and directed by engr in charge . note: gi pipe and fittings shall be measured and paid separately under relevent items . , labour for attending gi pipe line complaints ( break downs ) in buildings fifth to eigth storey including terrace for pipe of size 20 mm to 50 mm dia including cutting and threading of pipes as per site requirement including necessary scaffolding and safety measures complete all as specified and directed by engr in charge . note: gi pipe and fittings shall be measured and paid separately under relevent items . , all as per si item no . 5 . above but nine to twelveth storey , supply only gi tubing medium grade of following sizesnote: the quoted rates shall be deemed to include gi sockets and gi nipple as required at site . , 15 mm bore , 20 mm bore , 25 mm bore , 40 mm bore , 50 mm bore , 80 mm bore , supply only gi elbow of the following sizes , 15 mm bore , 20 mm bore , 25 mm bore , 50 mm bore , 80 mm bore , supply only gi union of the following sizes , 15 mm bore , 20 mm bore , 25 mm bore , 50 mm bore , 80 mm bore , supply and fix 25 mm dia gun metal gate valve , with iron wheel head , screwed both ends for iron pipe and fixed including cutting the pipe line and taking down old unserviceable valves wherever required complete all as specified and directed by engr in charge . , all as per sl item no . 10 above but 40 mm dia . , all as per sl item no . 10 above but 50 mm dia . , all as per sl item no . 10 above but 80 mm dia . , excavation in trenches n . exc . 1 . 5 m wide and n . exc . 1 . 5 m in depth and getting out in soft / loose soil for foundation , of pipe lines etc , complete all as specified and directed . , returning , filling in including spreading , levelling , watering and well ramming in layers not exc 25 cm thick in soil complete all as specified and directed . , removing surplus excavated soil n . exc . 50 m and depositing where directed at a level n exc 1 . 5 m above the starting point complete all as specified and directed . , supply and laying gi pipes medium grade of 20 mm dia with all fittings and fixtures fixed to walls / under floor complete including taking down old unserviceable one all as specified and directed . , all as per sl item no . 17 above but 25 mm dia . , all as per sl item no . 17 above but 40 mm dia . , all as per sl item no . 17 above but 50 mm dia . , all as per sl item no . 17 above but 80 mm dia . , m&l for pcc 1:3:6 , type c1 ( using 20 mm graded granite stone aggregate ) as in bases/ pedestals for pipe lines , mud stops or chamfered on edges , including dismantling existing complete all as specified and as directed . , m&l masonary valve chamber of size 900x900x900 mm ( internal dimensions ) and including necessary excavation and earth work in any type of soil , 100 mm thick pcc 1:4:8 type d2 foundation , brick work in cement mortar 1:6 , plastering internal and external surface 15 mm thick in cm 1:4 , 50 mm thick pcc 1:3:6 type c1 ( using 20 mm graded stone aggregate ) coping , 50 x 50 x 6 mm thick ms angle iron , 5 mm thick ms plate cover with locking arrangement , painting exposed steel surfaces with two coats of synthetic enamel paint over a coat of zinc chrome primer including dismantling unserviceable compete all as specified and directed by engr in charge . , all as per sl . item no . 23 above but of size 600x600x600 mm ( internal dimensions ) , all as per sl . item no . 23 above but of size 1200x1200x1200 mm ( internal dimensions ) , s&f 32 mm ( outer dia ) 3 layer pp r ( polypropylene random copolymer ) concealed sdr 7 . 4 stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all pp r plain and brass threaded polypropylene random fittings fixed to walls , ceilings etc , complete including taking down old unserviceable gi pipe all as specified and directed by engineer in charge: , all as per sl item no . 26 above but of size 40 mm ( outer dia ) , all as per sl item no . 26 above but of size 50 mm ( outer dia ) , all as per sl item no . 26 above but of size 63 mm ( outer dia ) , all as per sl item no . 26 above but of size 90 mm ( outer dia ) , m&l for ms plates 5 mm thick and over ( plain or chequered ) channels , square cut or notched ( ordinary and counter sunk ) forming holes , without any attachment of fe 410 ( grade e250 ) quality a including dismantling unserviceable one complete all as directed . , m&l for taking out existing filter media from gravity type filter bed , stacking the same neatly in dry condition after through cleaning and segregating media for re use complete all as directed by engineer in charge . , m&l for cleaning of internal walls of filter bed of capacity 10000 gallons per hour by brushing with nylon brush and cleaning using bleaching powder , washing with fresh water and applying one coat of white wash on external surface complete all as specifed and directed . , laying only filter media of any type as approved by engineer in charge ( obtained from item no . 32 ) in filter bed complete all as directed , supply and lay pebbeles filter media of size ( 1/8x1/16 , 1/4 x 1/8 , 1/2x1/4 , 1x1/2 , 1 . 5x1 ) in layers as required complete all as directed . note: contractor shall get the sample approval before commencement of work , supply and lay filter coarse gravel/ fine gravel of size 1/4 , 1 1/4 in layers as required complete all as directed . note: contractor shall get the sample approval before commencement of work , supply and lay filter media sand ( silica sand grade ) 14/30 mess sand ( fine sand ) in layers as required complete all as directed . note: contractor shall get the sample approval before commencement of work , m&l for peparation of bottom surface of filter bed backwash drain valve by grinding and cutting edges to provide smooth surface for jointing with new rubber sheet of 6mm thick ( pressure rating 10 kg/sqcm ) and fixing new ss nuts & bolts complete complete all as directed by engr in charge . , supply only calcium based , high strength chlorination chemical for disinfectant , in granual form for water treatment in factory sealed non returnable hdpe containers ( 40 to 50 kg each ) having chlorine concentration level of 70% complete all as specified and as directed . make: rayalaseema or its equivalent make as approved by e in c...

Military Engineer Services - Andhra Pradesh

24231711 manning , operation and maintenance of stp at naushakti vihar and misc works under age e / m no . i of ge ( utility ii ) visakhapatnam , manning and operation of sewage treatment plant of capacity 750m3 / day ( 750kld ) of make m / s hydrotech paryavaran ltd at naushakti vihar including operation maintenance of submersible / centrifugal type sewage pump sets including related lt panels and its connected accessories of sewage pump houses at naushakti vihar for operation and using chemicals for stp as required round the clock in 3 shifts per day of 08 hour each by employing one well experienced ( skilled ) operator in the trade complete all as specified and as directed by engr in charge . , manpower : one skilled operator per shift of 08 hrs including sundays and holidays all as directed by engineer in charge . shift timings: i st shift 0600 hrs to 1400 hrs ii nd shift 1400 hrs to 2200 hrs iii rd shift 2200 hrs to 0600 hrs , all as per sl item no . 1 above but one hepler ( un skilled ) in general shift of 08 hours . , manpower : one un skilled helper in general shift of 08 hrs including sundays and holidays all as directed by engineer in charge . shift timings: i st shift 0900 hrs to 1700 hrs , notes for si item nos 1& 2: ( a ) keeping the installations area neat and clean ( b ) keeping daily record of dg sets / pumps running status all as specified and directed in a log sheet . ( c ) rectifying minor defects such as arresting of pipeline leakage , greasing , oilings of pumps , gland packing , fuse wire , etc whenever required . ( d ) carrying out a check of dg set daily as per manufacturers manual . ( e ) replacing of distilled water / battery electrolyte and charging of batteries of dg sets . ( g ) the operator shall be alert to run the dg set within 5 minutes of supply failure . , ( h ) diesel shall be issued by department as and when required . contractor shall have to intimate minimum 03 days in advance for issue of diesel . notes for si item no 1 & 2: ( k ) cleaning of bar screen cum oil & grease separation chamber all as directed by engr in charge . ( l ) cleaning of sludge drying beds all as directed . ( m ) operation of arboricuture pumpsets including control for supplying treated water as and when required . ( n ) during the operation of the plant , the mlss ( mixed liquid suspended solids ) shall be maintained not less than 4000 mg / ltr in eco r tank . , manning and operation of pump house , dg set and diesel driven fire fighting pump set and electrical driven fire fighting pump set inlcluding lt panels , pressure vessels and accessories round the clock in 3 shifts per day of 08 hour each complete all as specified and as directed by engr in charge . , manpower : one skilled operator and one semi skilled helper per shift of 08 hrs including sundays and holidays all as directed by engineer in charge . shift timings: i st shift 0600 hrs to 1400 hrs ii nd shift 1400 hrs to 2200 hrs iii rd shift 2200 hrs to 0600 hrs , notes for si item no 1 to 3: ( a ) before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of ge duly recomended by engineer in charge . ( b ) the installation / plant room should be maintained neat and clean . , material and labour for cleaning of rcc equilisation tank of approx size 10 m x 10 . 0 m x 2 . 5 m at naushakti vihar stp 750 kld capacity by bailing out the accumulated raw water at the bottom and removing the complete silt / sludge / dirt from the tank and dispositing away exc 1 . 5 km and n . exc 5 . 0 km from site as directed , scrapping the tank inner walls and bottom with wire brush and cleaning the tank inner walls and bottom with the bleaching powder slurry completely including applying one coat of white wash to entire tank externally complete all as directed by engineer in charge . note: ( a ) the rate deemed to be inclusive of t&p and transportation required for disposal of sludge / dirt away from the site . ( b ) the cleaning of tank shall be performed every month as per manufacturers recommendations . ( c ) the rate quoted is per cleaning only . , all as per sl item no . 4 above but rcc treated water tank of approx size 10x10x2 . 5 metre at naushakti vihar stp 750 kld capacity , material and labour for choke clearing of submersible pump of 750 kld capacity stp ( size 13 . 2 x 6 . 6x 4 . 2 metre ) at sewage pump house / stp including dewatering the sewage sump to bottom level by using diesel driven mobile pump set type / submersible type , lifting submersible pump with delivery main from bracket at bottom of sewage sump of depth 3 mtr to 5 mtr by using pully & chain block up to floor level , removing all debris from pump casing , removing defective d clamps etc . inspecting impeller , bearing , by passing under current relay , testing the pump , lowering the pump with delivery main through guide wire rope by chain block , setting the pump to bottom bracket , testing the pump complete all as directed . , note : ( a ) the job to be completed with in 02 hours from choking of pump . ( b ) the quoted rate is deemed to be include the tool & plants required for lifting , inspection , lowering etc . , . ( c ) all safety measures including lighting , safety shoes , safety glows to be provided by contractor . , material and labour for chlorination of treated sewage water with sodium hypochiorite solution ( grade i ) as per is 11673 1992 for treatment of sewage water at stp for maintining residual chlorine all as per manufacturers recommendations / instructions . make: sree rayalseema solution or its equivalent as approved by ge . , m / l for chlorination treatment of water with stable bleaching power ( sbp ) ( calcium hypochloride ) grade i , availabilty chlorine 34 % min , stability 1 / 15 max , moisture 0 . 3% max etc . , complete all as specified and as directed . make: lion / vikram / shriram ( dcm ) or its equivalent as approved by ge , m&l for taking out existing pumpset / airblower of 15 to 20 hp capacity for servicing by disconnecting motor and blower / pump set from pipe line and removing of all parts like bearing , bushes , impeller , shaft etc . , cleaning all surfaces and scales / sludge / dirt / formed inside / out side pumpset / blower etc , lubricating / greasing at proper places and re fixing in position with all serviceable parts including painting with one coat of anti corrosive paint over red oxide primer and writing mes / sm no and testing and commissioning complete all as directed by engineer in charge . note: spares shall be measured and paid separately under relavent items of boq . , all as per sl item no . 9 above but 10 to 12 . 5 hp capacity , all as per sl item no . 9 above but 5 to 7 . 5 hp capacity , supply only ball bearings suitable for 15 to 20 hp capacity pumpsets / airblower , supply only ball bearings suitable for 10 to 12 . 5 hp capacity pumpsets / airblower , supply only ball bearings suitable for 5 to 7 . 5 hp capacity pumpsets / airblower , material and labour for cleaning and changing of multi grade sand filter of approx size 1600 x 2500 mm at naushakti vihar stp 750 kld capacity by bailing out the accumulated raw water at the bottom and removing the complete silt / sludge / dirt from the tank and dispositing away exc 1 . 5 km and n . exc 5 . 0 km from site as directed , scrapping the tank inner walls and bottom with wire brush and cleaning the tank inner walls and bottom with the bleaching powder slurry completely and changing the mixed filter sand and mixed sand media and gravels including applying one coat of paint to entire tank externally complete all as directed by engineer in charge . note: ( a ) the rate is deemed to be inclusive of t&p an...

Military Engineer Services - Andhra Pradesh

24199528 manning and operation and maintenance of dg sets , swimming pool , fire fighting installations at svn colony pump house and dg set at jack well no . 2 at megadrigedda under age e / m no . i of ge ( utility ii ) visakhapatnam , manning and operation of pump house and dg set at jack well no . 2 round the clock in 3 shifts per day including sunday / holiday complete all as specified and directed . man power: one skilled operator ( fgm ) and one helper per shift of 08 hours in three shifts per day and timings as under . ist shift 0600 hrs to 1400 hrs iind shift 1400 hrs to 2200 hrs iiird shift 2200 hrs to 0600 hrs , list of plants to be operated are as under: ( i ) vt pumps upto 60 hp 3 nos . ( ii ) dg set 125 kva 1 no . note: ( a ) the megadrigedda water supply installation is situated 13 km ( approx ) away from the city and further jack well no . 2 is located 1 . 5 km ( approx ) from megadhrigedda pump house . b ) the operator shall be alert to run the dg sets within 5 minutes of supply failure and ensure the operation of dg set every day . c ) the quoted rate is also inclusive of the following: i ) topping up / changing of engine oil as and when required . ii ) topping up of the diesel issued by the department . iii ) maintenance / recharging of batteries . ( iv ) supply and filling of distilled water / electrolyte to batteries / radiator as and when required . , manning and operation of swimming pool of capacity 9 , 04 , 000 litres at svn colony , 104 area by operating the installed machineries and equipment i . e . , pressure feed type filtration plant , and connected pump sets , air compressor , gravity feed type filter , gaseous chlorine plant , bleaching dozer , alum dozer , soda ash dozer , copper sulphate dozer , ammonia dozer and suction sweeper for maintaining the pool water to desired level of purity including attending to normal routine maintenance of installed plants / machinery / systems such as washing filtration plant etc required for operational purpose of swimming pool for smooth and trouble free operation complete all as specified and directed . , man power : one skilled operator and one semi skilled helper per shift of 08 hours in two shifts per day including sundays and holidays . note : ( a ) chemicals consumed shall be measured and paid separately under relevant item of boq . ( b ) operating of suction sweeper for cleaning of swimming pool shall be inclusive of quoted rate . ( c ) swimming pool platform area & edges to be cleaned regularly . , shift timings: ist shift 0600 hrs to 1400 hrs iind shift 1400 hrs to 2200 hrs , mannning and operation of pump house , dg set and diesel driven fire fighting pump set and electrical driven fire fighting pump set including lt panel , pressure vessel and accessories round the clock in three shifts a day including holidays and sundays at svn colony complete all as specified and directed . manpower : one skilled operator and one semi skilled helper per shift of 8 hours in three shifts per day and timings as under . ist shift 0600 hrs to 1400 hrs iind shift 1400 hrs to 2200 hrs iiird shift 2200 hrs to 0600 hrs , list of equipments are as under: ( a ) pump sets 75 hp 02 nos ( b ) dg set 500 kva capacity : 1 no ( c ) diesel driven pump set 120 hp capacity : 1 no ( d ) centrifugal pump set 120 hp capacity electric driven ac , 3 phase including control gear : 01 no ( e ) jockey pump set 30 hp electric driven ac , 3 phase including control gear : 01 no the quoted rate is inclusive of the following : i ) topping up / changing of engine oil as and when required . ii ) topping up of the diesel issued by the department . iii ) maintenance / recharging of batteries . iv ) supply and filling of distilled water / electrolyte to batteries / radiator as and when required . ( v ) maintenance of log book for the installation ( vi ) minor repairs should be attended . , mannning and operation of dg sets at officers mess , nirman park round the clock in three shifts per day including sundays and holidays complete all as specified and directed by engineer in charge . man power : one skilled operator per shift of 8 hours in three shifts per a day and timings as under . ist shift 0600 hrs to 1400 hrs iind shift 1400 hrs to 2200 hrs iiird shift 2200 hrs to 0600 hrs , list of equipments are as under: ( a ) dg set 62 . 5 kva capacity 1 no ( b ) dg set 40 kva capacity 1 no ( c ) lt panel for dg set : 02 no ( d ) main lt panel for 400 kva transformer : 01 no ( e ) amf panel for dg set 02 nos , notes : a ) the operator shall be alert to run the dg sets within 5 minutes of supply failure and ensure the operation of dg set every day . b ) the quoted rate is also inclusive of the following: i ) topping up / changing of engine oil as and when required . ii ) topping up of the diesel issued by the department . iii ) maintenance / recharging of batteries . iv ) supply and filling of distilled water / electrolyte to batteries / radiator as and when required . ( v ) maintenance of log book for the installation ( vi ) minor repairs should be attended . note for item no . 1 to 4 ( i ) before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of ge duly recomended by engineer in charge . , supply only sodium hypochloride . , supply only soda ash , supply only chlorine gas supplied in 100 kg cylinders for water treatment . make: andhra sugars or its equivalent make approved by state jal board as approved by ge note: ( i ) testing the cylinders , and repair to outlet valves of cylinders and maintain the gas control and regulating system shall be the responsibility of contractor and the rate is deemed to be included for the same ( ii ) chlorine gas will be supplied in 100 kg cylinder only . , supply only copper sulphate , supply only alum ( crystal type ) , supply only bleaching powder make: lion / vikram , supply and replace nylon brushes for suction sweeper as per existing size and make complete all as directed , supply and replace spare parts for chloronorm plant gravity feed as per sample including taking down the unserviceable spare parts of the chloronation plant complete all as directed , primary pressure guage stainless steel body , panel connecting copper tube set , pressure releasing valve ( diaphram primary ) , mixing chamber with glass , primary filter pv 01 , supply and replacement 25 mm dia high density polythene pipe ( hdpe ) of pressure rating 6 kg / sqcm , including making leak proof joints complete all as specified and directed by engineer in charge , supply and replacement self reinforced pvc 50 mm dia helifier hose in suction sweeper pump , including making leak proof joints complete all as specified and directed by engineer in charge , m&l for cleaning of ug sump / balancing tank for swimming pool of 50000 litres capacity by pumping out the accumulated water in the bottom and removing the complete silt from the sump and depositing at a distance 1 . 5km outside md land and levelling as directed and cleaning with bleaching powder and wire brushing the sump after scrapping the walls and bottoms of the sumps completely without disturbing the filtration pump to swimming pool including painting the sump and lettering the sump capacity , date of cleaning and due date of cleaning on the sump wall and applying one coat of white wash to entire sump all as per directed . , m& l for cleaning of swimming pool of capacity 9 , 04 , 000 litres by pumping out the accumulated water in the bottom and removing complete silt from the pool and depositing at a distance 1 . 5km outside md land and lev...

Military Engineer Services - Andhra Pradesh

24144721 manning and operation of ac plants at bldg 600 lt ( old ) , bldg no . p 314 , p 316 , including preventive/ periodical , maintenance of carrier ac plants under age e/m no . ii of ge ( utility ii ) visakhapatnam . , manning , operation and maintenance of central ac plants 3x20 tr , water cooled type including attending to minor defects for smooth and trouble free operation and keeping an hourly record of temparatures ( plant and inside rooms ) round the clock in 03 shifts of 08 hours each per day including sundays and holidays complete all as directed by the engineer in charge . man power: one skilled operator per shift round the clock . plant: ac plant at bldg no . p 7 , ( nad ) . note: the si item no . 01 shall be commence from 07 july 2020 . , outsourcing of services for operation and maintenance of central ac plants 3x23 tr , air cooled type including attending to minor defects for smooth and trouble free operation and keeping an hourly record of temparatures ( plant and inside rooms ) round the clock in 03 shifts of 08 hours each per day including sundays and holidays complete all as directed by the engineer in charge . man power: one skilled operator per shift round the clock . plant: 600 lt ( old ) ac plant at bldg no . p 348 , ( nad ) . , outsourcing of services for operation and maintenance of central ac plants 3x40 tr , air cooled type including attending to minor defects for smooth and trouble free operation and keeping an hourly record of temparatures ( plant and inside rooms ) round the clock in 03 shifts of 08 hours each per day including sundays and holidays complete all as directed by the engineer in charge . man power: one skilled operator per shift round the clock . plant: b shed ac plant at bldg no . p 316 , ( nad ) . , manning , operation and maintenance of central ac plants 3x23 tr , air cooled type including attending to minor defects for smooth and trouble free operation and keeping an hourly record of temparatures ( plant and inside rooms ) round the clock in 03 shifts of 08 hours each per day including sundays and holidays complete all as directed by the engineer in charge . man power: one skilled operator per shift round the clock . plant: c shed ac plant at bldg no . p 318 , ( nad ) . , note for sl item no . 1 to 4 : a ) two units shall run at a time and one as standby in each ac plant . b ) the quoted rate is inclusive of replacement of bolts , nuts , washers , greasing , gland packing to pump etc . , c ) the quoted rate is also inclusive of checking of oil levels in compressor leak test , changing of v belts , control wiring minor spare if any all as directed but excluding major spares/repairs to the plants . d ) refrigerant gas and compressor oil required for operation of the plants shall be measured and paid separately as supply only . e ) the quoted rate is also inclusive of cleaning of plants daily and keeping the plant rooms neat and dust free . e ) the quoted rate is also inclusive of maintaining log sheets and uniform of duty persons . , ( f ) before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of ge duly recomended by engineer in charge . , m&l overhauling for 40 tr capacity cooling tower , including aligning of fan blades , replacment of ct motor bearings , shaft bush and carrying out repairs to cooling tower ( fpr type ) , replacement of defective parts such as nozzles , mesh , common header , valve pipe , tee and bends , bolts and nuts , servicing of stainer , replacement of defective mesh , bottom base , arresting of leakages and removing of fungus from ct base , and applying one coat of white washing to the the pcc base complete all as specified directed by engineer in charge . , m&l for descaling of 20 tr capacity condensers by isolating the condenser by closing the water inlet and outlet connections , re circulating dilute hcl by descaling pump until the scale is removed , opening the both end covers of the condenser , brushing the condenser water tubes with nylon brush until the scale and dust deposits are removed , neutrlising with caustic soda solution , flushing out the tubes with fresh water , refixing the condenser end covers after replacing the worn out minor parts like gaskets , bolts , nuts , washers etc , opening the inlet and outlet water line connections and including testing and commissioning complete all as specified and directed by engr in charge . , disconnecting the filter bed from the ahus of various sizes , cleaning the air filters , removal of complete dirt deposited inside the cooling coil fins area by spray of scale removing agent and flushing out with fresh water till removal of complete dirt from the fins area , flushing out with air bolwer , refixing the same in existing position complete all as specified and directed by the engineer in charge . , supply and replace thermostatic expansion valve suitable for upto 8 . 5/8/7 . 5 tr complete all specified and as directed . make: sporlon/ u flow/ carrier , supply and replace power contactor 3 pole , 415 volts , 50 hz , ac , mnx type 32 amps all as specified and directed by engr in charge . , removing the old paints with the help of smooth brush of carrier air cooled out door unit ac plants and applying the paint with spray gun with of existing colour code of the plants , including two coats of white wash to pcc foundation and writing of sm/mes no . complete all as specified and directed . , m&l for carrying out leak test for ductable package/split ac plants of capacity upto 5 . 5 tr using nitrogen gas and rectifying the leakages , arresting the leakages , including charging gas , testing and commissioning complete all as specified and directed by engineer in charge . note: ( i ) necessary copper pipes , welding works are deemed to be included in the quoted rate . ( ii ) refrigerant gas r 22 shall be measured and paid separately . , all as per sl item no . 11 above but 7 . 5/8 . 5 tr capacity . , all as per sl item no . 11 above but 20 tr capacity condensor/ compressor . , supply and replace butterfly valves of cast iron 100/125 mm dia complete all as specified and as directed . make: l&t/ advance/audco/ kirloskar/ fountain , supply and replace loading pilot solenoid valve coil complete all as specified and as directed . make: sporlon/ u flow , m & l for disconnecting motor upto 2 hp capacity from the existing place ( ahu/chiller/condenser pump set/ blower motor etc . , ) and rewinding the motor with appropriate gauge super enamelled copper conductor of approved make , varnishing drying , replacement of worn out bearing ( de& nde ) , bushed connectors , terminal plate and fixing back in original position , connecting cable through terminal block , including painting the motor with two coats of synthetic enamel paint of smoke grey colour over one coat of red oxide zinc chrome primer including testing and commissioning complete all as directed . , all as per sl . item no . 16 above but motor of capacity 5 to 7 . 5 hp , all as per sl . item no . 16 above but motor of capacity 10 hp , supply only refrigerant gas r 22 . make: floron/mafron , supply only compressor oil . make: veedol 68/sheetal n 68 , supply only refrigerant gas r 410amake: floron/mafron , m & l for jungle cleaning by cutting and clearing away all grass vegetation , wild growth , sapling , shrubs , brushwoods , under growth roots , cutting of bushes , tree trunk of girth not execeeding 30 cm , cutting of trunk , portion protuding over ground , filling holes and leveling of ground and removing unserviceable materials to a distance n . exe 50m , compelte all as speicified , material & labour for removal of the damaged fan blades of the out door unit o...

Military Engineer Services - Andhra Pradesh

24141540 manning and operation and maintenance of stps at l , m e sector alongwith connected misc e/m works at dolphin hills under age e/m no . ii of ge ( utility ii ) visakhapatnam , manning / operation and maintenance of sewage treatment plant at l sector area , sequential batch reactor type , of capacity 350 cum/day of make: m/s acme enviro solutions private ltd consisting of bar screen cum oil & grease separation chamber , equalisation tank , eco r reactor , chlorine contact cum treated water tank , sludge drying beds , sewage transfer pumps , air blower , sludge transfer pump , treated water transfer pump , arboriculture pumps , dg set of capacity 62 . 5 kva and connected valves & electric panels etc . , round the clock in manual mode/ programmable logic controlled auto mode for treating raw sewage all as per manufacturers instructions/ recommendations for smooth and trouble free operation in three shifts including operation of dg set of 62 . 5 kva during power failure all as specified and directed by engineer in charge . , manpower : one skilled operator and one helper per shift of 08 hrs for first two shifts and one skilled operator for third shift all as directed by engineer in charge . shift timings: i st shift 0600 hrs to 1400 hrsii nd shift 1400 hrs to 2200 hrsiii rd shift 2200 hrs to 0600 hrs , note for item no . 1 to 3 : the rate quoted deemed to be inclusive of ( a ) keeping the installations area neat and clean by grass cutting and removing the debris in and around premises . ( b ) keeping daily record of all pumps running status all as specified and directed . ( c ) rectifying minor defects such as arresting of pipeline leakage , greasing of pumps , gland packing , fuse wire , repairs to foot valve etc whenever required . ( d ) carrying out a check of dg set daily as per manufacturers manual . ( e ) replacing of distilled water/battery electrolyte and charging of batteries of dg sets as and when required . ( f ) the installation will be handed over in operating state on the commencement of contract though work order . , ( g ) the operator shall ensure by trial run and be alert to run the dg set within 5 minutes of supply failure . ( h ) diesel shall be issued by department as and when required . contractor shall have to intimate minimum 03 days in advance for issue of diesel . ( j ) the quoted rate is inclusive collecting and transportation of diesel from age e/m store yard to work site . ( k ) cleaning of bar screen cum oil & grease separation chamber twice daily all as directed . ( l ) cleaning/slaking of sludge drying beds every week all as directed . ( m ) operation of arboricuture pumpsets including control for supplying treated water as and when required . ( n ) during the operation of the plant , the mlss ( mixed liquid suspended solids ) shall be maintained not less than 4000 mg/ltr in eco r tank . ( o ) the quoted rate inclusive for carrying out periodicals to stp buildings , including painting to doors , windows , connected pipe lines etc all as per existing once during entire contract period complete all as directed . , man power ( skilled ) employed shall have minimum 02 years work experience in operation of stp . , all as per sl item no . 1 above but stp at m sector . , all as per sl item no . 1 above but 750 kld mbbr type plant of make m/s hydrotech paryavaran ltd at e sector including operation & maintenance including periodical maintenance of submersible/ centrifugal type sewage pump sets including related lt panels and its connected accessories of sewage pump houses of north pocket & south pocket of e sector dolphin hills as when required and directed by engr in charge , material and labour for cleaning of rcc equilisation tank of approx size 5 . 5 m x 6 . 0 m x 5 . 74 m at l sector stp by bailing out the accumulated raw water at the bottom and removing the complete silt/sludge/dirt from the tank and dispositing away exc 1 . 5 km and n . exc 5 . 0 km from site as directed , scrapping the tank inner walls and bottom with wire brush and cleaning the tank inner walls and bottom with the bleaching powder slurry completely including applying one coat of white wash to entire tank externally complete all as directed by engineer in charge . note: ( a ) the rate deemed to be inclusive of t&p and transportation required for disposal of sludge/dirt away from the site . ( b ) the cleaning of tank shall be performed every month as per manufacturers recommendations . , all as per sl item no . 4 above but stp at m sector , all as per sl item no . 4 above but stp at e sector of approx size 12 . 7 metre dia and 2 . 0 metre height . , all as per sl item no . 4 above but rcc treated water tank of approx size 5x6x3 . 5 metre at l sector stp , all as per sl item no . 4 above but rcc treated water tank of approx size 5x6x3 . 5 metre at m sector stp , all as per sl item no . 4 above but rcc treated water tank of approx size 12 . 7 metre dia and 2 . 0 metre height at e sector stp , m & l for carrying out chemical analysis ( bod/cod ) test of treated sewer water of stp at l , m & e sectors from govt authorised laboratory all as per cpcb norms complete all as directed by engineer in charge . note : the rate quoted is deemed to be inclusive of testing and collection of water samples in sealed pvc container at stps . , removing old filter media complete of size 1/8 to 1/16 , 1/16 to 1/32 inch sizes complete in layers of sludge drying beds of size 4 x 2 . 50 x 1 . 4 m , scraping the internal surfaces of sludge drying beds with wire brush , and cleaning with bleaching powder slurry , cleaning with fresh water including applying one coat of white wash on external surface of sludge drying bed and re filling up with new filter media in layers all as per manufacturers recommendations / existing including testing and commissioning etc . , complete all as directed . note: new filter media will be measured and paid separately under relevant item of boq , supply only aggregate filter media for stp ( as per existing ) complete of size 1/8 to 1/16 , 1/16 to 1/32 inch size complete in layers as per existing complete all as specified and as directed . , m&l for maintenance of diesel engine connected with dg set 62 . 5 kva for b check as per recomendation of manufacturers instructions including replacement of filters , accessories like fuel filter with ring , air filter and ring , super bypass filter element , o ring seal , oil filter and engine oil complete all as specified and directed by engr in charge . , material and labour for chlorination of treated sewage water with sodium hypochiorite solution ( grade i ) as per is 11673 1992 for treatment of sewage water at stp for maintining residual chlorine all as per manufacturers recommendations/ instructions . make: sree rayalseema solution or its equivalent as approved by ge . , supply only alum ( white colour granual ) , m & l for jungle cleaning by cutting and clearing away all grass vegetation , wild growth , sapling , shrubs , brushwoods , under growth roots , cutting of bushes , tree trunk of girth not execeeding 30 cm , cutting of trunk , portion protuding over ground , filling holes and leveling of ground and removing unserviceable materials to a distance n . exe 50m , compelte all as speicified . , m& l for servicing of lt panels of any size by cleaning the panel , bus bar chamber with ctc solution , and welding the door using arc welding and fixing hinges , necessary nut and bolts , washers and made it completely functional for open/ close including painting of panel by spraying with two coats of epoxy based paint over a coat of red oxide primer , after cleaning of rusty panel surface both inside/ outside by emery paper and necessary preparation of smooth surface suitable for painting and in...

Military Engineer Services - Andhra Pradesh

24141519 manning , operation and maintenance of stp at naushakti vihar and misc works under age e / m no . i of ge ( utility ii ) visakhapatnam , manning and operation of sewage treatment plant of capacity 750m3 / day ( 750kld ) of make m / s hydrotech paryavaran ltd at naushakti vihar including operation maintenance of submersible / centrifugal type sewage pump sets including related lt panels and its connected accessories of sewage pump houses at naushakti vihar for operation and using chemicals for stp as required round the clock in 3 shifts per day of 08 hour each by employing one well experienced ( skilled ) operator in the trade complete all as specified and as directed by engr in charge . , manpower : one skilled operator per shift of 08 hrs including sundays and holidays all as directed by engineer in charge . shift timings: i st shift 0600 hrs to 1400 hrs ii nd shift 1400 hrs to 2200 hrs iii rd shift 2200 hrs to 0600 hrs , all as per sl item no . 1 above but one hepler ( un skilled ) in general shift of 08 hours . , manpower : one un skilled helper in general shift of 08 hrs including sundays and holidays all as directed by engineer in charge . shift timings: i st shift 0900 hrs to 1700 hrs , notes for si item nos 1& 2: ( a ) keeping the installations area neat and clean ( b ) keeping daily record of dg sets / pumps running status all as specified and directed in a log sheet . ( c ) rectifying minor defects such as arresting of pipeline leakage , greasing , oilings of pumps , gland packing , fuse wire , etc whenever required . ( d ) carrying out a check of dg set daily as per manufacturers manual . ( e ) replacing of distilled water / battery electrolyte and charging of batteries of dg sets . ( g ) the operator shall be alert to run the dg set within 5 minutes of supply failure . , ( h ) diesel shall be issued by department as and when required . contractor shall have to intimate minimum 03 days in advance for issue of diesel . notes for si item no 3 & 4: ( k ) cleaning of bar screen cum oil & grease separation chamber all as directed by engr in charge . ( l ) cleaning of sludge drying beds all as directed . ( m ) operation of arboricuture pumpsets including control for supplying treated water as and when required . ( n ) during the operation of the plant , the mlss ( mixed liquid suspended solids ) shall be maintained not less than 4000 mg / ltr in eco r tank . , notes for si item no 1 to 2: ( a ) before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of ge duly recomended by engineer in charge . ( b ) the installation / plant room should be maintained neat and clean . , material and labour for cleaning of rcc equilisation tank of approx size 10 m x 10 . 0 m x 2 . 5 m at naushakti vihar stp 750 kld capacity by bailing out the accumulated raw water at the bottom and removing the complete silt / sludge / dirt from the tank and dispositing away exc 1 . 5 km and n . exc 5 . 0 km from site as directed , scrapping the tank inner walls and bottom with wire brush and cleaning the tank inner walls and bottom with the bleaching powder slurry completely including applying one coat of white wash to entire tank externally complete all as directed by engineer in charge . note: ( a ) the rate deemed to be inclusive of t&p and transportation required for disposal of sludge / dirt away from the site . ( b ) the cleaning of tank shall be performed every month as per manufacturers recommendations . , all as per sl item no . 3 above but rcc treated water tank of approx size 10x10x2 . 5 metre at naushakti vihar stp 750 kld capacity , material and labour for choke clearing of submersible pump of 750 kld capacity stp ( size 13 . 2 x 6 . 6x 4 . 2 metre ) at sewage pump house / stp including dewatering the sewage sump to bottom level by using diesel driven mobile pump set type / submersible type , lifting submersible pump with delivery main from bracket at bottom of sewage sump of depth 3 mtr to 5 mtr by using pully & chain block up to floor level , removing all debris from pump casing , removing defective d clamps etc . inspecting impeller , bearing , by passing under current relay , testing the pump , lowering the pump with delivery main through guide wire rope by chain block , setting the pump to bottom bracket , testing the pump complete all as directed . , note : ( a ) the job to be completed with in 02 hours from choking of pump . ( b ) the quoted rate is deemed to be include the tool & plants required for lifting , inspection , lowering etc . , . ( c ) all safety measures including lighting , safety shoes , safety glows to be provided by contractor . , material and labour for chlorination of treated sewage water with sodium hypochiorite solution ( grade i ) as per is 11673 1992 for treatment of sewage water at stp for maintining residual chlorine all as per manufacturers recommendations / instructions . make: sree rayalseema solution or its equivalent as approved by ge . , m / l for chlorination treatment of water with stable bleaching power ( sbp ) ( calcium hypochloride ) grade i , availabilty chlorine 34 % min , stability 1 / 15 max , moisture 0 . 3% max etc . , complete all as specified and as directed . make: lion / vikram / shriram ( dcm ) or its equivalent as approved by ge , m&l for taking out existing pumpset / airblower of 15 to 20 hp capacity for servicing by disconnecting motor and blower / pump set from pipe line and removing of all parts like bearing , bushes , impeller , shaft etc . , cleaning all surfaces and scales / sludge / dirt / formed inside / out side pumpset / blower etc , lubricating / greasing at proper places and re fixing in position with all serviceable parts including painting with one coat of anti corrosive paint over red oxide primer and writing mes / sm no and testing and commissioning complete all as directed by engineer in charge . note: spares shall be measured and paid separately under relavent items of boq . , all as per sl item no . 8 above but 10 to 12 . 5 hp capacity , all as per sl item no . 8 above but 5 to 7 . 5 hp capacity , supply only ball bearings suitable for 15 to 20 hp capacity pumpsets / airblower , supply only ball bearings suitable for 10 to 12 . 5 hp capacity pumpsets / airblower , supply only ball bearings suitable for 5 to 7 . 5 hp capacity pumpsets / airblower , material and labour for cleaning and changing of multi grade sand filter of approx size 1600 x 2500 mm at naushakti vihar stp 750 kld capacity by bailing out the accumulated raw water at the bottom and removing the complete silt / sludge / dirt from the tank and dispositing away exc 1 . 5 km and n . exc 5 . 0 km from site as directed , scrapping the tank inner walls and bottom with wire brush and cleaning the tank inner walls and bottom with the bleaching powder slurry completely and changing the mixed filter sand and mixed sand media and gravels including applying one coat of paint to entire tank externally complete all as directed by engineer in charge . note: ( a ) the rate is deemed to be inclusive of t&p and transportation required for disposal of sludge / dirt away from the site . ( b ) mixed filter sand and mixed sand media and gravels shall be measured and paid separately under relavent items of boq . , material and labour for cleaning and changing of multi grade sand filter of approx size 2400 x 2500 mm at naushakti vihar stp 750 kld capacity by bailing out the accumulated raw water at the bottom and removing the complete silt / sludge / dirt from the tank and dispositing away exc 1 . 5 km and n . exc 5 . 0 km from site as directed , scrapping the tank inner walls and bottom with wire brush and cleaning the tank inner walls and bot...

Military Engineer Services - Andhra Pradesh

24043697 manning and operation and maintenance of dg sets , swimming pool , fire fighting installations at svn colony pump house and dg set at jack well no . 2 at megadrigedda under age e/m no . i of ge ( utility ii ) visakhapatnam , manning and operation of pump house and dg set at jack well no . 2 round the clock in 3 shifts per day including sunday/ holiday complete all as specified and directed . man power: one skilled operator ( fgm ) and one helper per shift of 08 hours in three shifts per day and timings as under . ist shift 0600 hrs to 1400 hrsiind shift 1400 hrs to 2200 hrsiiird shift 2200 hrs to 0600 hrs , list of plants to be operated are as under: ( i ) vt pumps upto 60 hp 3 nos . ( ii ) dg set 125 kva 1 no . note: ( a ) the megadrigedda water supply installation is situated 13 km ( approx ) away from the city and further jack well no . 2 is located 1 . 5 km ( approx ) from megadhrigedda pump house . b ) the operator shall be alert to run the dg sets within 5 minutes of supply failure and ensure the operation of dg set every day . c ) the quoted rate is also inclusive of the following: i ) topping up/changing of engine oil as and when required . ii ) topping up of the diesel issued by the department . iii ) maintenance/recharging of batteries . ( iv ) supply and filling of distilled water / electrolyte to batteries /radiator as and when required . , manning and operation of swimming pool of capacity 9 , 04 , 000 litres at svn colony , 104 area by operating the installed machineries and equipment i . e . , pressure feed type filtration plant , and connected pump sets , air compressor , gravity feed type filter , gaseous chlorine plant , bleaching dozer , alum dozer , soda ash dozer , copper sulphate dozer , ammonia dozer and suction sweeper for maintaining the pool water to desired level of purity including attending to normal routine maintenance of installed plants /machinery/ systems such as washing filtration plant etc required for operational purpose of swimming pool for smooth and trouble free operation complete all as specified and directed . , man power : one skilled operator and one semi skilled helper per shift of 08 hours in two shifts per day including sundays and holidays . note : ( a ) chemicals consumed shall be measured and paid separately under relevant item of boq . ( b ) operating of suction sweeper for cleaning of swimming pool shall be inclusive of quoted rate . ( c ) swimming pool platform area & edges to be cleaned regularly . , shift timings: ist shift 0600 hrs to 1400 hrsiind shift 1400 hrs to 2200 hrs , mannning and operation of pump house , dg set and diesel driven fire fighting pump set and electrical driven fire fighting pump set including lt panel , pressure vessel and accessories round the clock in three shifts a day including holidays and sundays at svn colony complete all as specified and directed . manpower : one skilled operator and one semi skilled helper per shift of 8 hours in three shifts per day and timings as under . ist shift 0600 hrs to 1400 hrsiind shift 1400 hrs to 2200 hrsiiird shift 2200 hrs to 0600 hrs , list of equipments are as under: ( a ) pump sets 75 hp 02 nos ( b ) dg set 500 kva capacity : 1 no ( c ) diesel driven pump set 120 hp capacity : 1 no ( d ) centrifugal pump set 120 hp capacity electric driven ac , 3 phase including control gear : 01 no ( e ) jockey pump set 30 hp electric driven ac , 3 phase including control gear : 01 no the quoted rate is inclusive of the following :i ) topping up/changing of engine oil as and when required . ii ) topping up of the diesel issued by the department . iii ) maintenance/recharging of batteries . iv ) supply and filling of distilled water / electrolyte to batteries /radiator as and when required . ( v ) maintenance of log book for the installation ( vi ) minor repairs should be attended . , mannning and operation of dg sets at officers mess , nirman park round the clock in three shifts per day including sundays and holidays complete all as specified and directed by engineer in charge . man power : one skilled operator per shift of 8 hours in three shifts per a day and timings as under . ist shift 0600 hrs to 1400 hrsiind shift 1400 hrs to 2200 hrsiiird shift 2200 hrs to 0600 hrs , list of equipments are as under: ( a ) dg set 62 . 5 kva capacity 1 no ( b ) dg set 40 kva capacity 1 no ( c ) lt panel for dg set : 02 no ( d ) main lt panel for 400 kva transformer : 01 no ( e ) amf panel for dg set 02 nos , notes : a ) the operator shall be alert to run the dg sets within 5 minutes of supply failure and ensure the operation of dg set every day . b ) the quoted rate is also inclusive of the following: i ) topping up/changing of engine oil as and when required . ii ) topping up of the diesel issued by the department . iii ) maintenance/recharging of batteries . iv ) supply and filling of distilled water/electrolyte to batteries/radiator as and when required . ( v ) maintenance of log book for the installation ( vi ) minor repairs should be attended . note for item no . 1 to 4 ( i ) before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of ge duly recomended by engineer in charge . , supply only sodium hypochloride . , supply only soda ash , supply only chlorine gas supplied in 100 kg cylinders for water treatment . make: andhra sugars or its equivalent make approved by state jal board as approved by genote: ( i ) testing the cylinders , and repair to outlet valves of cylinders and maintain the gas control and regulating system shall be the responsibility of contractor and the rate is deemed to be included for the same ( ii ) chlorine gas will be supplied in 100 kg cylinder only . , supply only copper sulphate , supply only alum ( crystal type ) , supply only bleaching powder make: lion/ vikram , supply and replace nylon brushes for suction sweeper as per existing size and make complete all as directed , supply and replace spare parts for chloronorm plant gravity feed as per sample including taking down the unserviceable spare parts of the chloronation plant complete all as directed , primary pressure guage stainless steel body , panel connecting copper tube set , pressure releasing valve ( diaphram primary ) , mixing chamber with glass , primary filter pv 01 , supply and replacement 25 mm dia high density polythene pipe ( hdpe ) of pressure rating 6 kg/ sqcm , including making leak proof joints complete all as specified and directed by engineer in charge , supply and replacement self reinforced pvc 50 mm dia helifier hose in suction sweeper pump , including making leak proof joints complete all as specified and directed by engineer in charge , m&l for cleaning of ug sump/ balancing tank for swimming pool of 50000 litres capacity by pumping out the accumulated water in the bottom and removing the complete silt from the sump and depositing at a distance 1 . 5km outside md land and levelling as directed and cleaning with bleaching powder and wire brushing the sump after scrapping the walls and bottoms of the sumps completely without disturbing the filtration pump to swimming pool including painting the sump and lettering the sump capacity , date of cleaning and due date of cleaning on the sump wall and applying one coat of white wash to entire sump all as per directed . , m& l for cleaning of swimming pool of capacity 9 , 04 , 000 litres by pumping out the accumulated water in the bottom and removing complete silt from the pool and depositing at a distance 1 . 5km outside md land and lev...

National Seeds Corporation Limited - Andhra Pradesh

23152207 supply , installation , testing and commissioning of 250kva substation including all allied equipment and civil work 1. 11 kv joint kit 2. ci earth pipe 3. gi earth pipe 4. copper earth flat 5. 3x50 sq mm 11 kv ht xlpe ug cable 6. load breaker / circuit breaker 7. ms channel 8. earth channel 9. ht metering material including 2.5 sq mm wire & gi pipe of suitable size etc. complete as required 10. 250 kva dtr 5 star rating copper wound transformer 11. 3.5x150sq mm underground cable 12. outdoor lamp and switch with proper protection for lighting 13. 250 ampare 4 pole change over switch 14. drawing & approval of safety from dir, ap govt. / concern department of ap 15. providing noc from dy. dir, ap / concern department of ap. 16. labour charge fro electrical workn inclusive of all charges 1. retaining wall ( height 1 mtr, width 0.3mtr ) ( foundation 0.5mtr, width 0.6mtr ) including finishing and white wash. 2. transformer platform structure ( 1.5mx1.5m ) ( walls 0.3mtr, height 2mtr, foundation depth 0.5 mtr ) including finishing, white wash &earth filling 3a m 20 rcc for making transformer bad ( 1:1.5:3 ) 20mm coarse aggregate ( 1.5mtrx1.5mtr x0.300 mtr ) 3b double steel mesh 66m length ( 16mm dia at 150mm spacing ) 4. mild steel angle ( 2 mtr height ) inclusive finishing with primer ( 40x40x6mm ) 5. gi fencing wire mess ( 36mx2m ) ( cell size 50x50, wire thickness 3mm ) inclusive paitning with primer 6. iron gate ( 1.5x1.5mtr ) inclusive finishing with primer and required items 7. supply and filling of sand ( 11x7x0.5mtr ) 8. yard filling with stone gravels ( 11x7x0.5mtr ) 9. danger board, safety board and substation details board...

Forest Department - Andhra Pradesh

22650821 supply and fixing of iron and other items for repairs, white washing and painting to to arc i and arc ii night houses in svzp, tirupati during 2019 20 1 supply and fixing of ms c channels of size 50x100x50mm and its fabrication like cutting, bending and welding and fixing etc complete ( as per go ) 2 supply and fixing of 50x6mm ms flats and its fabrication like cutting, bending and welding and fixing etc complete ( as per go ) 3 supply and fixing of 50x50x6mm ms l angle and its fabrication like cutting, bending and welding and fixing etc complete ( as per go ) 4 supply and fixing of cleat flats and its fabrication like cutting, bending and welding and fixing etc complete ( as per quotation including gst ) 5 supply and fixing of 3 bolts and nuts etc., complete ( as per quotation including gst ) 6 supply and fixing of 4 x 1 / 2 nylon wheels etc., complete ( as per quotation including gst ) 7 supply and fixing of welding rods etc., complete ( as per quotation including gst ) 8 supply and fixing of cutting wheels ( 14 size ) etc., complete ( as per quotation including gst ) 9 supply and fixing of grinding wheels etc., complete ( as per quotation including gst ) 10 supply and fixing of welding glass etc., complete ( as per quotation including gst ) 11 supply and fixing of binding wire ( gi ) etc., complete ( as per ssr 2018 19 part i basic input data for wr work items si no.3 ) 12 supply and fixing of 4 double ball bearing wheel including all charges etc., complete ( as per quotation including gst ) 13 supply and fixing of 4 bolt and nut with washer including all charges etc., complete ( as per quotation including gst ) 14 removing white wash / colour wash / enamel paint by steel wire brushing and / or scraping; sand papering including all charges etc., complete ( bld cstn 14 1 ) 15 white washing two coats with whiting of approved quality to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials including cost of all materials, labour charges and incidental such as scaffolding, lift charges etc., complete for finished item of work, but excluding conveyance charges of materials ( bld cstn 11 5 ) 16 painting two coats with synthetic enamel paint over one coat of red oxide primer to old ms iron work ( total three coats ) including cost and conveyances and labour charges etc. complete ( ( bld cstn 12 7 ) + ( bld cstn si.no 197 ) ) ...

Indian Navy - Andhra Pradesh

22585520 tender for making arrangement at rk beach for naval ops display at visakhapatnam: 01 making seating gallery of six line on both sides at main vvip venue with carpet. stage size 40x29.5 mtrs. for 02 and 04 dec 19 02. construction of strong double barricades on beach size 800x2.3 mtrs. and single barricade 800 mtrs on both side of stage for 02 and 04 dec 19 03. hiring of plastic chairs without arms &with white cover, transport, spreading for 02 and 04 dec 19 04 hiring of plastic chairs without arms, transport, spreading for 02 and 04 dec 19 05. providing p.a . system from kali temple till the pandurangapuram down with 6 no cordless , 6 cord mikes, cd player, amplifier, mixer, 2 stage monitiors for vip stage etc on 02, 03 and 04 dec 19 06. halogens 20 nos for illumination on the stage area including surrounding of seating arrangements both at main venue on 02, 03and 04 dec 19 07. air conditioner 1.5 ton for the cabins on 30 nov, 01, 02, 03, and 04 dec 19 08. providing of generator 7.5 kva with diesel, 90 mtr cabling, transport diesel, changeover, operator etc on 01, 02, 03 and 04 dec 19 for control system 09. providing of generator 7.5 kva with diesel, 90 mtr cabling, transport diesel, changeover, operator etc on 01, 02, 03 and 04 dec 19 for sound system 10 providing of generator 62.5kva with diesel, 90 mtr cabling, transport diesel, changeover, operator etc on 02, 03 and 04 dec 19 for light and standby power 11 temporary toilet with commodes, water and maintenance on 02 and 04 dec 19 12 hiring of usl for conservancy at rk beach on 04 dec 19 13. making of one in number box type entrance gate, top 18’x2’ and pillar 2 x 10’ – 01 no decorated with framed flex board from all four side on 02 & 04 dec 19 14. providing of guard rails / barricades from main stage ( 30’ both sides ) on 02 and 04 dec 19 15. decoration of band stage vvip stage and surrounding area ( carpeting 60’x40’ and 24’x16’ ) on 02 and 04 dec 19 16. wooden platform size 3x2x1 mtr to be erected on 02 and 04 dec 19 17. covering of main stage boot topping area from of all four sides on 02 and 04 dec 19 18. covering of band stage boot topping area for 02 and 04 dec 19 ( 60’x40’ 04 sides ) 19. teapoy with covering 02 and 04 dec 19 20 providing of condenser ground mikes with 40 mtr xlr cable for 60 x 40 stage on 02 and 04 dec 19 21 marking and display of flex banner size 12x12 with frames on 02 and 04 dec 19 22 marking of sign board as “no parking sailor & family, cmde & cdr & below size 18” x 4” etc for 02 and 04 dec 19 23 marking of sign board for the team as “commanding offices”, police, ncc cadets size 18” x 4” etc for 02 and 04 dec 19 24 providing of decorative flags of various colours 4’ x 2’ with wooden stick for 02 and 04 dec 19 25 white wash of compound wall in front of main stage 280’ x 120’ 26 provision of cables / supply to equipment in ops demo control room ( 04 core cable 60 mtr – 16 sqm ) 27 construction of strong metal with mess double barricade on both side of road size 600x2.3 mtrs with provision of 04 nos door at different places on road for 02 and 04 dec 19 28 led wall p10 board of size 10x7feet with cabling switcher and mounting of led wall on 8 feet height with generator power supply etc. for 02 and 04 dec 19 29 sofa two seater for 02 and 04 dec 19 30 vip area and walk way area carpet per 02 and 04 dec 19 31 02 nos video rec and photography for 02 and 04 dec 19 32 sofa single seater 02 and 04 dec 19 33 vip chairs with cover for 02 and 04 dec 19 34 construction of additional strong single barricade as required size 400x 2.3 mtr on 02 and 04 dec 19...

South Central Railway - Andhra Pradesh

22000073 supply of supply of r.c.c. earth pit box including covers of size 450 x 450 x 50mm along with white wash., supply of r.c.c. earth pit box including covers of size 450 x 450 x 50mm along with white wash....

Military Engineer Services - Andhra Pradesh

21681571 repair/maintenance of ht vcb panel including calibration of relays and repair/maint of street light security lights high mast lt panels ug cables etc incl certain misc work at inhs kalyani under age e/m no i of ge u i visakhapatnam , disconnecting defective oudoor/indoor power distribution transformer of 315/400/500/1000 kva rating from ht/lt and earth conection and taken out from the sub stn / plinth and transporting to workshop taking out complete transformer oil , storing the same in suitable containers ( to be provided by contractor ) opening top cover and lifting up the core assembly carefully to check the condition of transformer winding core refixing the same after repair refilling the transformer oil after dehydration and filteration ( dehydration and filteration to be paid separately ) including checking of leakage of transformer body and welding works required for making transformer body leak proof , applying two coats of synthetic enamel paint over the transformer body after preparation of surfaces , tranportation of transformer from work shop to site and reinstalling the same at any site and connecting and testing complete all as directed by engr in charge . the materials required for rectification of defects such as rewinding / core / transformer oil bushes etc shall be measured and paid searately . , supply only the following items for item no 01 here in before , ( a ) ht copper coil made out of proper size of dpc copper wire super enamelled of high quality matching with the existing impedance and insulation of all as specified and as directed by engr in charge . , ( b ) reconditioning of lt copper coil after providing necessary insulating material , glass sleeves etc all as directed at site by engr in charge . , ( c ) ht bush rod made out of copper with brass nuts and washers of required quality and size suitable for 315 kva to 1000 kva transformer , ( d ) ht bushing porcelain suitable for for 315 kva to 1000 kva transformer complete with gaskets . , ( e ) lt bush rod suitable for 315 kva to 500 kva transformer with washer complete , ( f ) lt bushing porcelian suitable for for 315 kva to 500 kva transformer complete with gaskets . , ( g ) synthethetic rubberised cork sheet gasket 1/4 thick suitable for main body of transforemr capacity upto 500 kva . , ( h ) silicagel dark blue laboratory grade of good quality , filteration of transformer oil of transfomers installed at various locations to achieve di eletric strength not less than 50 kv at 2 . 5mm gap as per relevant is with portable filteration plant , testing of the oil for the di electric strength before filtratin and after filtration complete all as directed by the engr in charge . , supply and topping up of transformer oil with di electric strenght not less than 50 kv in to the conservator tank/ body tank of the transformer at various locations complete all as directed by the engr in charge . make: power oil/ transoil/ sabitha chemicals/electrol , m&l for preparation of old painted surfaces of transformers with coarse cloth/ brush and painting throughout externally on exposed surfaces with two coats of smoke grey colour synthetic enamel paint including writing of transformer details on plinth in white enamel paint on black enamel paint back ground complete including one coat of white wash for base foundation all as specified anddirected by engineer in charge for the following capacity in door/ out door type transformer: , ( a ) 200kva/315 kva/400 kva , ( b ) 500 kva , ( c ) 1000 kva , s & f in replacement of mild steel plates ( plain or chequered ) , channels , angle irons , square cut or notched ( ordinary and countersunk ) forming holes , without any attachment conforming to fe 410 w inlcuding applying two coats of synthetic enameled paint over a coat of red oxide zinc chrome primer including dismatling old rusted one in any description all as directed . , supply & replace 11kv potential transformer type vir= 11000/rt3/110/rt3/110/rt3v , va=100/50 vf; 1 . 2cont&1 . 9 for 8 hours , voltage transformer single phase type hsv/il , 12/28/75 kv all as specified , supply & replace cable jointing kit for 11kv grade cable for indoor termination heat shrink type jointing complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cablie of size 185 sqmm , complete including testing after jointing all as specified . make; birla 3m / denson / raychem , supply & replace cable jointing kit for 11kv grade cable for outdoor termination heat shrink type jointing complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cablie of size 185 sqmm , complete including testing after jointing all as specified . make; birla 3m / denson / raychem , supply & replace cable jointing kit for 11kv grade cable for straight through joint heat shrink type jointing complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cablie of size 185 sqmm , complete including testing after jointing all as specified . make; birla 3m / denson / raychem , m&l for strip opening the ht panel of rating 11 kv , 3 phase comprising of following repairs , inspecting , overhauling and servicing/ of vcb complete all as directed . make: cg . a ) opening the complete instrument chamber/ hv cable box/lv cable box . decarbonising/ cleaning the complete ht 11 kv 3 phase independent bus bar , bus bar chamber of ht panel and inspecting the bus bar insulators . b ) checking , inspecting , calibration of idmt relays , ammeters and voltmeters etc complete . c ) checking complete electrical tripping circuit of ht panel including control wiring from secondary system rotary to tripping coil , auxiliary switch male and female housing cut out , etc . and wiring including replacement of damaged wire at places including operation on dc system , testing and commissioning complete all as directed . , supply and replace on load change over switch 4 pole 630 amps with front operated handle in sheet metal enclosure complete with necessary connections all as required at site . make: standard/hpl/havells , repair/servicng of lt air circuit breaker of 630/800 amps capacity of l&t make complete including strip opening and checking and cleaning of contacts , arc chutes , tightening of all connections , setting and calibration of tripping relay , greasing of all mechanical parts and replacing minor parts like thimbles , control cables , nuts , bolts etc through the authorised service engineer and testing complete all as directed . , supply & fixing of volt meter of size 96mmx96mm range , 0 500 v digital type with inbuilt selector switch . make: ae / imp / meco / mei/ hpl/ conzerv/ l&t , supply & fixing of ammeter , of size 96 x96 mm digital type , with suitable cts and inbuilt selector switch . make: ae / imp / meco / mei/ hpl/ conzerv/ l&t , supply & fixing of indication lamp led type , ( r , y , b ) . make: kaycee / technik / l & t , supply and fix lighting arrester ht 11 kv 10 ka station class all as per specified and directed by engr in charge make : jaipuria , supply and laying ht ug xlpe insulated , pvc sheated , bedded , galvanised steel strip or wire armoured heavy duty electric power cable of size 3 core 185 sqmm , 11 kv grade ( earthed ) stranded aluminium conductor laid in trenches / passing through pipe/duct/wall complete including taking out old u/s cable all as specified and directed by the engineer in charge . make : finolex / polycab / havells / gloster / kei industries ltd / asian cables , supply& replace heat shrink type cable jointing kit for straight through joint for lt cable complete with jointing material and accessories suitable for 4 core 6 to 16 sqmm xlpe armoured aluminum cable , jointing and testing after completion all as specified . make; birla 3m / den...

Military Engineer Services - Andhra Pradesh

21565592 manning and operation of the operation and maintenance of 11 kv chitra sub station at naval park and certain miscellaneous works at naval park and amzari park under age e/m no i of ge utility i visakhapatnam , out sourcing for operation and maintenance of ht/lt electrical sub stations at naval park and the equipments installed round the clock in 03 shifts of 08 hours each all as per the details given below: out sourcing : minimum one skilled electrician and one mate electrician per shift of 08 hours , note: ( i ) contractor is responsible to keepintg the installations clean and tidy by cleanig daily as directed . , ( ii ) the contractor is responsible for the operation of all outdoor/ indoor structures under this out sourcing , ( iii ) the operator should liaise with command swimming pool sub station for any major break down/ failure for early restoratioin of electric supply immediately , ( iv ) contractor is responsible for arranging technical manpower to rectify the defects inside the sub stn as required at site at the earliest , ( v ) in case any problem occurs which seems not under the control of operator , the same shall be immediately intimated to je i/c or age e/m over telephone . , ( vi ) the contractor is also responsible for the monitoring and operation and maintenance of street lights in the above areas . , ( vii ) contractor is responsible for all safety precuations as per ie rules of operators deployed in ht/lt installation under the ca , m & l painting poles with two coats of synthetic enamel paint aluminium and writing pole no with synthetic paint and fixing of two nos red colour radium reflected sticker around the pole including white wash on coping all as directed , s & f frp loop in loop out boxes copatible to fix mcb with mounting rails , cable connector including provn of suitable gi clamps for fixing to pole , pvc glands of hansu model hb 14 or equivalent in sintex / hensal complete all as directed , earthing complete with galvanised steel earthplate of size 60x60cmx6 . 3mm thick electrode and 32x6mm gi strip as earth lead , buried directly in ground ( earth pit not less than 2 . 25m deep below ground level ) with top edge of the plate not less than 1 . 5m below ground level , connected to 32x6mm earth strip by means of nuts , bolts , check nuts and washers of gi all as shown in electrical plate no . 5 of ssr part i , connected to earth test terminal point all as specified or as indicated including testing on completion ( rates inclusive of neccessary excavation in any type of soil , earth work , pcc pit , ci cover , funnel with watering pipe , suitable size of light grade gi protection pipe for earth strip in ground etc . all as required at site for complete earthing ) . , m &l for cement concrete pcc 1:2:4 b1 using 20 mm aggregrate pole coping including two coats of white wash , removal old coping , and taking out the broken materils from the site etc complete all as specified and directed , m&l for providing , injecting and spraying of chemical emulsion treatment with round up chemical from m/s monsanto for anti growth of grass and vegetation complete all as directed . , s & f 3 core 1 . 5 sq mm multi stranded copper conductor , pvc insulated unshethed cable for connecting junction box to street light fitting complete all as directed . , s & f in repairs ballast hpsv/mh 400 w all as directed by engr in charge , s & f in repairs electornic igniter for hpsv/mh lamps 400w all as directed by engr in charge , s & f in repairs lamp mh 400 w green colour with theard all as directed by engr in charge , s & f in repairs lamp led 9 w /11 w all as directed by engr in charge , s & f in repairs mccb 200 a , 16 ka 4 pole , 415v all as directed by engr in charge , s & f in repairs screw type holder / b22 base holder all as directed by engr in charge , s & f in repairs led driver suitable for 45/60 watt led fitting all as directed by engr in charge , s & f in repairs mccb 250 a , 25 ka 4 pole , 415v all as directed by engr in charge , s & f in repairs led driver suitable for 90/100 watt led fitting all as directed by engr in charge , s & f in repairs led driver suitable for 135/150 watt led fitting all as directed by engr in charge , s & f in repairs mccb 400 a , 25 ka 4 pole , 415v all as directed by engr in charge , s & f in repairs led phase indicating lamps , all as directed by engr in charge , s & f in repairs mccb 100 a , 16 ka 4 pole , 415v all as directed by engr in charge , s & f in repairs mccb 63 a , 16 ka 4 pole , 415v all as directed by engr in charge , s & f in repairs digital ammeter/voltmeter , 415 v all as directed by engr in charge , s & f in repairs ct , s suitable to ammeters to read /indicate up to 1000 amps all as directed by engr in charge , s & f in repairs digital timer switch ( with battery backup ) 3p module 24 hrs program , current capacity 16a , s & f in repairs ballast hpsv/mh 250 w all as direted by engr in charge , s & f in repairs lamp mh 250 w with theard all as direted by engr in charge , supplying , fixing and testing of post top lanthern lights for garden and slope areas 10w led integral decorative led bollard with opal acrylic with ip 65 protection of make bajaj / cg / philips including taking out old one . , excavation in trenches n . exc1 . 5 mtr wide and not exc 1 . 5 mtr depth and getting out hard/dense soil all as directed , returning and filling in of excavated soil of any type including spreading , levelling , watering and well ramming in layers not exceeding 25 cm each , removal of surplus excavated soil not exceeding 50 mtr and deposting where directed at a level not exceeding 1 . 5 mtr above starting point , m&l for sand cushining/sand covering for underground cable protection complete all as specified . note:punned thickness only will be measured and paid , supply and laying sub class b bricks of size 23x11x7 cm , supply and fix heat shirnkable type lt straight joint for cable3 . 5/4 core 25 sqmm to 50 sqmm size make : raychem/ birla 3m / denson , supply and fix heat shirnkable type lt straight joint for cable3 . 5/4 core 185 sqmm 240 sqmm sizemake : raychem/ birla 3m / denson , supply and fix heat shirnkable type lt straight joint for cable3 . 5/4 core 70 sqmm 150 sqmm sizemake : raychem/ birla 3m / denson , supplying , fixing and testing of gate lights 40w led post with die cast aluminium body and with white powder coated aluminium reflector and ip 65 protection of make cg / bajaj / havells / philips including taking out old one all as directed . , supply and laying or fixing or passing through pipe or in cable ducts , 11000 volts grade xlpe ( frls ) insulated heavy duty ( earthed ) , screened , pvc bedded , galvanised steel strip or wire armoured , electric power cables ( heavy duty ) with aluminium conductor 185 sq mm 3 core size including dismantling old one . make:nicco/polycab/havells/universal . , supplying , fixing and testing of flood light die cast aluminium of 200w , 230 volts ( maintaing minmum system lumen 20000 ) with ip 66 including inbuilt drive with all fixing arrangements with nuts&bolts , clamps , iron chanels on poles etc with warranty certificate complete all as specified and directed by engineer in charge including taking out old one make: havells jetairisplusfls200wled757psymltg / philips/wipro . , filtration of transformer oil of transformers installed at various locations to achieve di electric strength not less than 50 kv for 1 minute at 2 . 5mm gap as per relevant is with portable filtration plant , testing of the oil for the di electric strength complete all as specified and directed . , supply and topping up of transformer oil with di electric strenght not less than 50 kv i...

Military Engineer Services - Andhra Pradesh

21474207 out sourcing to the services for manning and operation of sea survival unit sewage pumps and repair and maintenance of ro plant at ins kalinga , out sourcing for manning and operation of sea survival unit at ins kalinga complex and comprising the following installed equipment by deploying one skilled pump operator for one shift per day including sundays and holidays complete all as specified and as directed by the engineer in charge: ( i ) pressure feed sand filter bed enclosed in ms hemispherical chamber with connected inlet and outlet valves pressure , indication etc . ( ii ) mono block pump set 2 nos . 3 phase 415 volt 7 . 5 hp capacity make: kirloskar ( iii ) lp air compressor 01 no . , 3 phase 415 volt 7 . 5 hp capacity make: kirloskar ( iv ) electrical panel with starter etc . operate the installed machinery shifts of 08 hours duration . ( v ) maintain the sea survival swimming pool including necessary dosage of precipitate copper sulphate . bleaching powder alum and the water shall be maintained to 0 . 2 ppm at swimming pool . note: the material used for cleaning of sea survival unit like chlorine granule , copper sulphate , alum , bleaching powder etc . shall be measured paid separately under the relevant items . , all as per item no . 1 above but one suction sweeper pump cleaner ( unskilled ) for one shift of 08 hours per day . , out sourcing to the services for manning and operation and maintenance of sewage pump house installation at ins kalinga complex comprising the jobs like cleaning of bar screen chamber , fab reactor , tube seltter and disposal of sludge from the sand beds and bars screen chamber etc . and comprising the following installed equipment by deploying one skilled operator for two shifts per day of each 08 hours including sundays and holidays complete all as specified and as directed by the engineer in charge: ( a ) non clogging pump set 15 hp 02 nos . ( b ) monoblock pump set 7 . 5 hp 02 nos . ( c ) dg set with lt panel board with starter 3 phase 415 volts including connected pipelines . ( d ) mbbr having capacity 100 cum 01 no . ( e ) monoblock pump set 10 hp 02 nos . ( f ) filter bed feeder pump 02 nos . ( g ) air blower 02 nos . ( h ) mgf 01 no . ( j ) acf 01 no . ( k ) dosing pump 01 no . note: chlorine gas will be measured paid separately . notes for item nos . 1 to 3:1 . wage paid by the contractor to the persons employed shall not be less than the minimum wages fixed by state/central government from time to time whichever is higher . the payment shall be made to the workers through a nationalised bank and the bank statement of fair wages as per minimum labour wages as mentioned above shall be submitted along with the rars/fb for payments . 2 . the contractor shall be responsible for the epf , esi , bonus , safety etc . and insurance of all tradesmen employed by him as per existing labour rules/acts/regulations . , supply only chlorine gas cylinder . note: testing the cylinder , repair to out let valves of cylinder , repairs to chlorine gas control and regulating system shall be the responsibility of the contractor and rate quoted is deemed to be included for the same . , supply only copper sulphate . make: hemal impex/parshva chemicals/prayug agro pvt ltd or any other equivalent or superior make as approved by ge . , supply only alum crystal . , supply only bleaching powder . make: vikram pac/aquafit , supply only soda ash . , supply only anti scalent liquid . , supply only sodium hypochlorite . , s&f in repairs pvc multiport valve 40nb ( 40mm ) size , 6 way , using wear resistant high hardness ceramic material spare parts with maximum operating pressure of 5kg/cm2 , suitable for 5000 lph ro plant complete all as specified and as directed by the engineer in charge . make: hayward/nitco/aventura/certikin or equivalent , s&f in repairs , dosing pump of capialy 6 lph complete all as specified and as directed by the engineer in charge . make: e dose , s&f in repairs , flow meter 5000 lph complete all as specified and as directed by the engineer in charge . , s&f in repairs , raw water meter 1200 lph complete all as specified and as directed by the engineer in charge . , s&f in repairs , ozonator 2 grams per hour with ss box complete all as specified and as directed by the engineer in charge . , s&f in repairs , uv strainer 2 gram per hour with ss box complete all as specified and as directed by the engineer in charge . , overhauling of suction sweeper pump of capacity 3 hp 440 volts with replacement of gear oil , v belt , water seal , o ring set etc . complete including reassembling back and testing complete all as specified and as directed by the engineer in charge . make: fenner , m&l for cleaning of water supply under ground sump for balancing capacity 30 , 000 gallons by bailing out the accumulated water at the bottom and taking out & removing the complete sludge out side land and wash out completely , and wire brushing the tanks after scrubbing the walls and bottom of the tank completely with minimum disturbance of water to swimming pool and applying two coats of white wash inside the tank complete all as specified and directed by engineer in charge . , m&l for cleaning of swimming pool of sea survival unit of capacity 1 , 00 , 000 gallons by bailing out accumulated water at the bottom and water over flow channels and cleaning the wall , bottoms surfaces by using suitable tiles scrubbers and acid without disturbance of wall/floor surfaces complete all as specified and as directed by the engineer in charge . , m&l for cleaning of filter media chamber and supply and replacement new 5 micron size filter in chamber at ro plant complete all as specified and as directed by the engineer in charge . , m&l for opening top cover of sand filter and replacement of sand 200 kg and reassembling the top cover of sand filter without disturbance of ro system complete all as specified and as directed by the engineer in charge . , s&f in repairs , 8mm thick frp pressure vessels 2472 , 610mm dia . and 2 . 438m long for sand filters of ro plant with 4 precision injected model with threaded opening and frp reinforced tripod base complete all as specified and as directed by the engineer in charge . make: aquas/lcm/jb drop/aventura/pentair , s&f nylon brush of size 0 . 60mx0 . 15m including nut , bolt , washers and springs etc . complete all as specified and as directed by the engineer in charge . , taking down and refixing nrv/sluice valve 50mm dia . after replacement of defective rubber gasket , nut , bolt , washers etc , complete all as specified and as directed by the engineer in charge . , s&f in repairs , pressure gauge ( 0 14 kg/cm2 ) including necessary specials including provision of suitable ferrule etc . complete all as specified and as directed by the engineer in charge . make: h guru/fiebig/abb manufacturing co . , s&f in repairs self reinforced pvc 50mm dia . helifier hoos in suction sweeper pump at sea survival unit all as specified and as directed by the engineer in charge . , m&l for taking out existing pressure filter media from the filter bed of 3m dia . and 1 . 5m height by opening the man hole and taking out carefully existing filter media of any size , stacking neatly after thorough cleaning and segregating the media of round pebbles and coarse gravels for reuse and cleaning of internal walls of pressure filter with bleaching powder solution by using the wire brush and applying two coats of synthetic bitumen paint complete all as specified and as directed by the engineer in charge . note: filling only/spreading only filter media will be measure and paid separately . , filling/spreading only the filter media ( pebbles ) obtained from item no . 20 above on the lower portion of the filter bed complete all as specified and as directed by the...