South Central Railway - Andhra Pradesh

34145761 supply of supply and fixing of 10 kva inverter 3phase on grid power condition unit with mppt technology to model no ksg iii 10kn of kirolskar make or similar make and as per the specification given below. max.dc i / p power 12kw, max.i / p current 13a / 13a max.dc i / p voltage 1000 volts start voltage 200 volts pv voltage range 160 v 1000 v. mppt operating voltage range / nominal voltage 450v 850v / 600v max i / p current per string 13a number of mppt 2 inputs per mppt 1supply and fixing of 10 kva inverter 3phase on grid power condition unit with mppt technology to model no ksg iii 10kn of kirolskar make or similar make and as per the specification given below. max.dc i / p power 12kw, max.i / p current 13a / 13a max.dc i / p voltage 1000 volts start voltage 200 volts pv voltage range 160 v 1000 v. mppt operating voltage range / nominal voltage 450v 850v / 600v max i / p current per string 13a number of mppt 2 inputs per mppt 1, supply and fixing of 10 kva inverter 3phase on grid power condition unit with mppt technology to model no ksg iii 10kn of kirolskar make or similar make and as per the specification given below. max.dc i / p power 12kw, max.i / p current 13a / 13a max.dc i / p voltage 1000 volts start voltage 200 volts pv voltage range 160 v 1000 v. mppt operating voltage range / nominal voltage 450v 850v / 600v max i / p current per string 13a number of mppt 2 inputs per mppt 1...

South Central Railway - Andhra Pradesh

34035801 auction sale of divisional stores depot guntur [ andhra pradesh ] condemned and unserviceable s&t scrap of battery chargers, track feed chargers, bm101chargers, smps chargers, upss, data hub, decoders, inverters, voltage regulators, stabilizers, etbs, ekts, dc dc converters and modules, 25w vhf charger, tms kit, pd mux, v.f repeater panel, stm equipments, da 100 controller, bp ac tx / rx coils, smrs, data logger, block instrument panel, voice logger, transformers, isolation transformers, invertors, stm equipment, transformer rectifier etc of various makes, types, capacities of sorts and sizes, full or broken with or without attachment of ms / pcb / pvc / core lamination. total qty: 14.985mts. said to contain approx. copper 775 kgs, approx. aluminium 180 kgs, approx. ms / pcb / pvc / core lamination 14030 kgs. location: in bin no:14 of dsd / gnt. note: [ 1 ] ms covers of battery chargers and battery chargers without transformers [ copper / aluminum coil ] are part of this lot, [ 2 ] delivery on actual weighment basis only, [ 3 ] segregation is not permitted, [ 4 ] the above non ferrous quantities mentioned are approximate only and purchaser should visit the lot for physical assessment of the above quantities in all aspects before bidding in e auction....

South Central Railway - Andhra Pradesh

33982776 auction sale of 16 coaches lot no 5622095006 at crs / tpty scrap depot, ap [ andhra pradesh ] available with cdms / sd / crs / tpty scrap depot. desc: cond.& u / s over aged bg coaches without bogie complete and wheel sets, coach nos ( 1 ) scaccn 98131 ( 2 ) scaccn 98135 ( 3 ) scaccw 98075 ( 4 ) scwgaccw 98068 ( 5 ) scaccn 98127 ( 6 ) scwfac 98001 eog ( 7 ) scwgaccn 98108 ( 8 ) scvpu 087834 ( 9 ) wgcb 98804 ( 10 ) scwgaccn 98103 ( 11scgs 98446 ( 12 ) wgcb 98809 ( 13 ) wgscn 98269 ( 14 ) wgscn 98274 ( 15 ) wgscn 97269 ( 16 ) wgscn 97339 rc items: ( 1 ) bogie complete with wheel sets:32nos ( 2 ) axle box with bearings:128nos ( 3 ) springs coil:384 nos ( 4 ) buffer complete fittings:51nos ( 5 ) screw coupling set complete:30nos & draw hook:01nos ( 6 ) brakecylinders / air brake:64nos ( 7 ) distributor valve with cpb ( common pipe bracket ) :04nos & cpb:04nos ( 8 ) controller reservoirs:07nos ( 9 ) aux. reservoirs:08nos ( 10 ) centre pivot:32nos ( 11 ) wash basins &wall protector :nil ( 12 ) bio toilet tanks:nil ( 13 ) stainless steel bp&fp:06nos ( 14 ) aluminium water tanks:04nos ( 15 ) ss baby tanks :20nos ( 16 ) bronze wearing pieces ( to be seen after cutting ) :44nos ( 17 ) peasd unit complete ( passenger emergency alarm signal device:18nos ( 18 ) cut off angle cock:40nos ( 19 ) alternators:02nos ( 20 ) regulator including tension rod:nil ( 21 ) battery sets:nil ( 22 ) carriage fans and light fittings:nil ( 23 ) wras:nil ( 24 ) ac equipment complete u / a :nil ( 25 ) rmpu with control unit ( roof mounted package unit ) :rmpu 06nos&control panels:04nos ( 26 ) battery charger:nil ( 27 ) inverters with panel:nil ( 28 ) power panel:03nos ( 29 ) pre cooling transformer:nil ( 30 ) capacitor bank:nil ( 31 ) exhaust fan:nil ( 32 ) emergency lights:nil ( 33 ) feeders junction boxes:nil ( 34 ) pantry equipments: nil ( 35 ) switch board cabinet:nil ( 36 ) wheel track line ( rails ) of coach no:scvpu 087834 to be returned to railways ( to be handed over to sse / cbr ) . net saleable weight :392.4324 mts approx ( including ms items wt: 357.1929 mts approx.; rexine , foam pvc & compreg wt:24.600 mts approx ; ss lavatory pan wt: 1.110 mts approx.;aluminium wt: 1.384 mts approx;ss under slung tanks: 4.400 mts approx; ss weight: 1.000 mts approx.; pvc copper cable wt: 2.7455 mts approx ) .note: ( 1 ) cutting is permitted to loadable sizes. ( 2 ) the quantity of rc items mentioned for the above list will be arrived as per the joint handing over memo issued by the railway authorities to the successful bidder at the time of cutting / handing over of the lot and the same list of rc items should be returned to railways by the purchaser. ( 3 ) railways does not guarantee for quality and quantity description etc. ( 4 ) any non ferrous items ( other than aluminum ) , electrical items, rc items found in excess to the above, at the time of cutting and delivery of coach should be returned to railways. ( 5 ) successful bidders must ensure the rc items at the time of taking over and same should be returned to custodian before effecting delivery. in case which are not able to see / count / weight before dismantling and same may be jointly inspected and soon after dismantling the same will be recorded. ( 6 ) the purchaser is responsible for providing adequate safety fire fighting equipment on the spot at the time of cutting and delivery. ( 7 ) the purchaser has to remove / clear the muck, mud and zero value items released from the condmned coaches at the location to nominated area in crs / workshop before taking final delivery of the lot. loc: 14 coaches available on track beside tl shop and 02 coaches on track behind main store depot .these 16 coaches will be moved to the road side lane no.1 and 2 of southside crs compound wall inside crs / tpty once the track is cleared.delivery on number basis only. total qty 16 numbers. pl no 98111048 ( 01 ) hsn code:72042990....

South Central Railway - Andhra Pradesh

33971237 supply of supply of igbt type 10kw capacity, on grid solar inverter with in built mppt confirming to is 16221 ( part 2 ) :2015 and is 16169:2014 as per enclosed specification of model psit 10k in polycab make or its equivalent in abb, microtek, luminous, hitachi, delta and sma.supply of igbt type 10kw capacity, on grid solar inverter with in built mppt confirming to is 16221 ( part 2 ) :2015 and is 16169:2014 as per enclosed specification of model psit 10k in polycab make or its equivalent in abb, microtek, luminous, hitachi, delta and sma., supply of igbt type 10kw capacity, on grid solar inverter with in built mppt confirming to is 16221 ( part 2 ) :2015 and is 16169:2014 as per enclosed specification of model psit 10k in polycab make or its equivalent in abb, microtek, luminous, hitachi, delta and sma....

South Central Railway - Andhra Pradesh

33969408 supply of supply of igbt type 5kw capacity, on grid solar inverter with in built mppt confirming to is 16221 ( part 2 ) :2015 and is 16169:2014 as per enclosed specification of model psit 5k in polycab make or its equivalent in abb, microtek, luminous, hitachi, delta and sma. note: 1. for at destination.supply of igbt type 5kw capacity, on grid solar inverter with in built mppt confirming to is 16221 ( part 2 ) :2015 and is 16169:2014 as per enclosed specification of model psit 5k in polycab make or its equivalent in abb, microtek, luminous, hitachi, delta and sma. note: 1. for at destination., supply of igbt type 5kw capacity, on grid solar inverter with in built mppt confirming to is 16221 ( part 2 ) :2015 and is 16169:2014 as per enclosed specification of model psit 5k in polycab make or its equivalent in abb, microtek, luminous, hitachi, delta and sma. note: 1. for at destination....

South Central Railway - Andhra Pradesh

33929833 auction sale of actual lot no. 03112209 0064. pl no.98414501 ( 13 ) [ hsn code: 85045010;gst@18% on rcm basis ] cond and us elec. scrap of 3 phase kwh meters, power capacitors, single phase kwh meters, led fittings 3 way, head lights, working light, change over switch tpic 63a 4 pole, led red, route, ekt / rkt, clf chocks:11w, mccb:250a, 400a, 100a63 / 60a, 40a, 15a, power capacitors, led signal aspect red, yellow, green , led shunt rout aspect, flex box, ct coils, timer, ftl lock holder, air cooler pump, 18 / 11 watts electrical ballast, glow sign boards, pit line light , loud speakers, halogen speakers, box type speakers, tv 21 inches make: samsung / onida, rotary switches , portable blower, mobile charging socket, cfl inverter : 11wates , cfl fittings twins 5 watts led, emergency light berth light fitting, 100 va inverter iron box type , double test lamp, emergency light fitting, cfl 11 watts, rru s :25kw, : 05no, errus25 kw:03no, high power 3 watt led based tri colure white , red, green , hand held torch light , hemet minor lights , kent gold water purifier, rotary cam switches, push button, colure lights, mcb, digital meters soldering coils, fuse base, forward / reverse switches, key switches , fling insert killer , multipurpose led based inspection lamp with and light service rechargeable, t5 fittings, coolers parts , operated hand signal lamp, t 5 / 28w indoor fittings, emergency light , led aspects shunt led, route / co on led aspects , main signal led s hg, rg, dg, ttm head working lights, moving coil instrument hooter , presser hydraulic , pneumatic gauges, tachometer, ro plants ( dismantling ) , dragon switches, led head lamp with chargers, tri color head lamps / single light, led lamp, aska light blower, root meter , chargers, pa speaker horn type, cabinet speaker, power spike, pf gps clocks, fare display board, soldering iron. full or broken. with or without attachments. said to contain copper: 48.159 kg, brass: 13.548 kg, aluminum : 323.742 kg, ms : 1244.825 kg, plastic: 796.693 kg, pcb: 471.203 kg, ss: 85.920 kg, glass: 86.510 kg, porcelain: 15 kg, location: right side of nf yard main road and drum no: 04, 26, 42 and 44, in nf ward , . ( images attached ) , ...

South Central Railway - Andhra Pradesh

33929825 auction sale of actual lot no 03112111 0003112209 0055. pl no. 98414653 ( 15 ) [ hsn code 84713010 gst18% on rcm basis ] cond and u / s computer scrap of canon laser jet printer model no : l 11121e, computer monitor make aoc / acer / hp / lcd monitors make : hp / , 24 inches lcd monitor , make samsung , lcd tv make : samsung , thin clients make : vxl / tayaltechl, computer cpu , make : hp / acer, scanner , make :numeric, printer : make : canon , willkie talkies set with battery , chargers , maintenance pc , computers make accer , hcl, hp, recah digital photo copier , 2 kav ups, 1kva ups, xerox machine , make :sharp , model : ar 5618s, computer with cpu and key board monitor mouse, make : dell, 1kva ups , make : numeric, printer old type, computer set assembled / cpu and with key board , mouse, and monitor , cable fault locater ( aplab ) , cross talk measuring set ( anuvidyut ) tms kit ( anuuvidyut ) . 1kva ups with batteries , 1 kva ups , ups 650 va, / 500 va modems g: 703 and v.35, lan extender, media converter, router, spot switch, ups 1kva, / 0.750 kva, printer / hp 4645 desl jet printer, nokia mobile ( old type ) , model : 6100 with ear phone, ricoh / dx2430 digital copy printer , computer monitors , cpu , ups, printer make :canon , key boards , rechargeable speakers , digital camera 7.1 mega plix ( nilon ) 32 inches led monitor , make : sky worth, laser printer, make : conon, tms kit, cable rout locator ( ridgid ) , fax machine ( panasonic ) , report generating terminal ( printer ) digital voice recorder, vhf set battery , ken wood 2207, battery 328, ( 481 kg approx ) chargers : ken wood, vhf set gp 328 , 2207, ( 76 kg approx ) adopters for vhf set ( 51 kg approx ) , antenna for vhf / set :5 w, vhf set , battery chargers rapid 328 model ( 68 kg approx ) vdu , printer , cpu wit key board , mouse, ups , embedded pc , 32 colum ribbon printer, cable assembly tp digital encoder, emergency power supply , electric control module , fuel relay , monitor touch screen, ups 120v / 1500 va, valve driver card, card 30t, 24sls, flc32 card, mcc32, card 4tem pri card, card 24 sa, power supply 19dc d ps for ipx, card 4twl, port e and m card, 8 btrp card, adsl +2 router , lane xtender 2mbps, nomus gateway modems, media converter, ups 600va, ups 1kva with built in battery backup 30m, wireless router tp link and link , data mini tabs / mantra tabs / biometric tabs, modems g703 and v35, lan extender 30mbps, vhf set , 4way station equipment, plat form announcement system, gsm router, pco fct, 48 v low voltage monitoring circuit, , fdms, pdch, ups ( intex, numeric, emerge, desk jet ink printer, ups 120v / 1500va , desktop computer with monitor , key board mouse and cpu make : hp printer ( dot matrix ) make :epsinkbs brand desktop , laser jet printer, hp office jet printer, ups 0.60 kva and 1kva, walkie talkie, . rapid battery charger cap 300mah, 2.0 va ups, lan extenders, ups different types, vhf set ( ken wood ) , charger vhf set gp, batteries, printers ( dot matrix 120 col / 80 col ) , conon multifunction inkjet printers g.3000, a3 / a4 scanner, multimedia projector , lamination machine, touch screen monitor, letter cutting machine , kiosk, 3kva ups / 2kva ups make : online, 2kva / 1kva ups, cpu / dell , make : dell, vhf sets with batteries chargers, computer sets dot matrix printers , ups , battery pack, vhf set , collar power block , ups computer set, inverters 1kva , hp deskjet ink printer , laser printer. ( cpcb holders only to bid ) full or broken. with or without attachments. location: in old office building and top of bin no :01 02 03 04 and 05 drum no : 46 and 19 in nf ward . ( images attached ) ....

Eastern Power Distribution Company Of Andhra Pradesh Limited - Andhra Pradesh

33898035 estimate for replacing the existing 12v / 100 ah batteries 30 nos. and 40 kva online ups system 01 nos. with new 40 kva online ups system ( 3ph in 3ph out ) double conversion igbt inverter online ups system fully microprocessor controller, isolation transformer based ups make mega power with 30 nos. 12v / 100ah smf batteries make quanta / exide and battery stand and interlink cables duly replacing the old system at apepdcl, circle office, building srikakulam...

National Thermal Power Corporation Limited - Andhra Pradesh

33882719 procurement of vertiv make ups and charger spares for ntpc vindhyachal. procurement of vertiv make ups and charger spares for ntpc vindhyachal. , igbt 75a, 1200v for hi rel ups , igbt gate drive card ( h5 ) hirel ups. , ac dc conv. pcb for ups system for stage , dc dc converter pcb for ups system for s , inverter logic pcb, libert ups , ups interface pcb ( hvi ) , libert ups , pca temp sensor board for fly ash ups , current transformer, part no:294904001010 , charging module, 24 75, with accessories , acu with controller: ngmc hf, 2x2u;emrsn , ib2 customer i / o board for ngmc #023517 , monitoring module, sm battery bmp 651 32 , spd, 3 phase, class c, 230 vac, 20ka;emer , pca modbus bridge board; emerson , connector: female housing 3pin, 35a, 300v , connector, female housing 10pin, 120v;emr , inductr:fxd:0.275 mh, 320 amp:almunium , lmp ind led:yelow:30mm:240vac, <1w , lmp ind led:blu:30mm:240vac, <1w , heatsinkthyristor type hl01 , thyrstr / scr: 190a, 1600v, heat sink mount , lmp ind led:red:30mm:240vac, <1w , cooling fan size: 8, voltage: 230vac , ct22kv:.415 / .6kv:800 / 0.2a:1.5va, cl0.1 , isolation xymr:3ph, 7.55kva, 415v / 415v, y0 , isolation xymr:3ph, 15.1kva, 415v / 415v, y0 , current transformer for current sensing , control xymr:60va, 220 240v / 17 0 17v , control transformer: primary 0 240 v, , capacitor dc:10000 mfd / 350 vdc for stage , panel synoptic pcb for ups system for st , ups logic pcb for ups system for stage i , pca panel synoptic ( mimic ) #100216120033 , parallel logic pcb for ups system for st , operator logic board#100215021031;emersn , rely inst volt:24v dc:vertiv:1c / o , rectifier logic board#100218031021;emrsn , thyristor pt:255905001400 , igbt dual module pt:254604001222 , fuse compl unit pt:284704506000 , fuse compl unit pt:284708006000 , axial fan pt:181000016000 , cooling fan 230vac, 20w 120x120mm , flat cable kit p / n: 271920025001;emrsn , igbt driver board#100209120023; emerson , rectifier driver board#100218011022;emrs , flat cables kit p / n: 271920105301;emer , pca board p / n: 100200000007; emerson , pca static switch driver for 3ph ups , unsync transfmr board #100203011021; emr , rc board pt#100218021022 => limited...

Department Of Atomic Energy - Andhra Pradesh

33855180 bids are invited for custom bid for services 1repair or retrofit and overhauling work on different type of one and half ton split type air conditioners along with required supply of spares and service , custom bid for services 2repair or retrofit and overhauling work of two ton cassette type air conditioners along with required supply of spares and service , custom bid for services 3repair or retrofit and overhauling work of two ton split type air conditioners along with required supply of spares and service , custom bid for services 4repair or retrofit and overhauling work of five and half ton duct type air conditioners along with required supply of spares and service , custom bid for services 5repair or retrofit or overhauling of air drier of capacity 03 ton 02 nos 06 ton 02 nos 11 ton 02 nos along with required supply of spares and service , custom bid for services 6repair or retrofit or overhauling of chiller units of capacity 11 ton 02 nos along with required supply of spares and service , custom bid for services 7repair or retrofit or overhauling of water coolers of capacity 190 ltrs 04 nos along with required supply of spares and service , custom bid for services 8repair or retrofit or overhauling of refrigerator of 220 ltrs along with required supply of spares and service , custom bid for services 9general maintenance work on different types windows split cassettee split inverter of one and half or two ton air conditioners on quarterly one visit basis for a period of one year note unit rate defined as four visits co.. , custom bid for services 10general maintenance work on different types duct or split type five and half or seven and half ton air conditioners on quarterly one visit basis for a period of one year note unit rate defined as four visits cost per m.. , custom bid for services 11general maintenance work on duct chiller type 15 ton or 25 ton air conditioners on quarterly one visit basis for a period of one year note unit rate defined as four visits cost per machine , custom bid for services 12general maintenance work on different capacity of air driers 03 ton 06 ton 11 ton each 02 nos chillers 11 ton 02 nos water coolers 06 nos refrigerators 04 nos on two visits per year basis note unit rate is avg cost of a.. , custom bid for services 13 breakdown maintenance work on different types windows split cassettee split inverter of one and half or two ton air conditioners as and bid number: gem / 2022 / b / 2515132 dated: 08 09 2022 bid document 1 / 42 inverter of one and half or two ton air conditioners as and when required basis during one year contract period , custom bid for services 14 breakdown maintenance work on different types duct or split of five and half or seven and half ton air conditioners as and when required basis during one year contract period , custom bid for services 15 breakdown maintenance work on different duct chiller type 15 ton or 25 ton air conditioners as and when required basis during one year contract period , custom bid for services 16 breakdown maintenance work on different capacity of air driers 03 ton 06 ton 11 ton each 02 nos chillers 11 ton 02 nos water coolers 06 nos refrigerators 04 nos as and when required basis during 01 yr note unit rate is a.. , custom bid for services 17 installation of split or inverter type new one and half or two ton acs in uciltummalapalle unit or ucil colony or near by locations during one year contract period note except supply of full ac unit remaining all are pure.. , custom bid for services 18 installation of split or duct type new five and half or seven and half ton acs in ucil plant colony villages during one year contract period note except supply of ac unit remaining all are in contractor scope , custom bid for services 19 removing shifting and re installation of one and half or two ton air conditioners in ucil plant colony near by villages as and when required basis during one year contract period note total work is purely contractor scope , custom bid for services 20 installation of split or inverter type new one and half or two on air conditioners in ucil hyderabad office upperpally as and when required basis during one year note except supply of ac unit remaining all are in contr.. , custom bid for services 21 removing shifting and reinstallation of one and half and two ton existing air conditioners in ucil hyderabad office upperpally as and when required basis during one year contract period note all works are purely in the s.....

Bharat Sanchar Nigam Limited - Andhra Pradesh

33842416 supply installation testing commissioning of 23 nos 1.5tr, 5 star non inverter type split ac units for te vengi and te kadappa telephone exchanges under bsnl ap circle...

Road And Building Department - Andhra Pradesh

33835775 construction of court building and residential quarter at kurupam in vizianagaram district. sub work: providing balance electrical installation, networking and inverters to the above building. (2nd call)...

Tirumala Tirupati Devasthanams - Andhra Pradesh

33824025 supply and installation of 3 feet dia pivot wall mounting fans ( inverter control a.c.motor ) to nadaneerajanam stage inside of sri.tt, tirumala , supply of 3 feet dia wall mounting type pivot fan ( inverter control ac motor technology ) with aerodynamic aluminum blades, supporting adjustable stand length upto 8 feets and adjustable mounting bracket to work with 230v, single phase ac system., installation charges...

Bharat Sanchar Nigam Limited - Andhra Pradesh

33809986 supply, installation, testing and commissioning of 23 nos 1.5tr, 5 star non inverter type split ac units for te vengi and te kadappa telephone exchanges under bsnl ap circle...

Endowment Department - Andhra Pradesh

33806648 supply of materials for online seva year 2022 2023 6th cal , ups 600mah 15 for poes backup power, 8ch poes giga port, 4ch poes giga port, media converters giga por, switchs 8 port giga, weather proof cat 6 boundless, honey well rj45 clips, laptop for ip cameras configuration in field work, networing tool kit, adaptors 12v, steel boxes to arrange power hubs, inverters 1050 with battery 180mah monitor section and nvr section, splicing machine for fiber work fujikura 38s or equivalent single fusion splicer with stripper cleavers all accessories and box, ofc 12ft, ofc 6ft...

Endowment Department - Andhra Pradesh

33806639 supply of c.c tv materials year 2022 23 2nd cal , ups 600mah 15 for poes backup power,8ch poes giga port,4ch poes giga port,media converters giga por,switchs 8 port giga,weather proof cat 6 boundless,honey well rj45 clips,laptop for ip cameras configuration in field work,networing tool kit,adaptors 12v,steel boxes to arrange power hubs,inverters 1050 with battery 180mah monitor section and nvr section,splicing machine for fiber work fujikura 38s or equivalent single fusion splicer with stripper cleavers all accessories and box,ofc 12ft,ofc 6ft...

South Central Railway - Andhra Pradesh

33788248 auction sale of 18coaches lot no 5622095005 at crs / tpty scrap depot, ap [ andhra pradesh ] available with cdms / sd / crs / tpty scrap depot .desc: cond.& u / s over aged bg coaches without bogie complete and wheel sets, coach nos ( 1 ) wgcb 98811 ( 2 ) wgscn 97238 ( 3 ) wgscn 97323 ( 4 ) wgscn 97329 ( 5 ) scwgaccn 98119 ( 6 ) wgscn 96310 ( 7 ) wgscn 94205 ( 8 ) scgslr 97722 ( 9 ) scaccn 98132 ( 10 ) scgs 98453 ( 11 ) scaccn 98129 ( 12 ) scaccn 98126 ( 13 ) scgslr 97709 ( 14 ) scgslr 98718 ( 15 ) scgslr 97764 ( 16 ) scgslr 97752 ( 17 ) scgslr 99702 ( 18 ) scgslr 99743 rc items: ( 1 ) bogie complete with wheel sets:36nos ( 2 ) axle box with bearings:144nos ( 3 ) springscoil:432nos ( 4 ) buffer complete fittings:64nos ( 5 ) screw coupling set complete:36nos ( 6 ) brakecylinders / air brake:68nos ( 7 ) distributorvalvewith cpb ( common pipe bracket ) :07nos& common pipe bracket:02nos ( 8 ) controller reservoirs:11nos ( 9 ) aux. reservoirs:13nos ( 10 ) centre pivot:36nos ( 11 ) wash basins &wall protector:nil ( 12 ) bio toilet tanks:nil ( 13 ) stainless steel bp&fp:01nos ( 14 ) aluminium water tanks:24nos ( 15 ) ss auxiliary baby tanks :04nos ( 16 ) bronze wearing pieces ( to be seen after cutting ) :72nos ( 17 ) peasd unit complete ( passenger emergency alarm signal device:15nos ( 18 ) cut off angle cock:40nos ( 19 ) alternators:02nos ( 20 ) regulator including tension rod:nil ( 21 ) battery sets:nil ( 22 ) carriagefans and light fittings:nil ( 23 ) wra?s:nil ( 24 ) ac equipment complete u / a:nil ( 25 ) rmpu with control unit ( roof mounted package unit ) :rmpu 06nos ( 26 ) control panels:nil ( 27 ) battery charger:nil ( 28 ) inverters with panel:01nos ( 29 ) power panel:01nos ( 30 ) pre cooling transformer:nil ( 31 ) capacitor bank:nil ( 32 ) exhaust fan:nil ( 33 ) emergency lights:nil ( 34 ) feeders junction boxes:nil ( 35 ) pantry equipments:nil ( 36 ) switch board cabinet:nil.net saleable weight :412.8607 mts approx ( including ms items wt:379.1397 mts approx; rexine , foam pvc flooring sheet&compreg sheets wt:23.500 mts approx; aluminium wt:4.175 mts approx ; ss through floor wt: 0.443 mts; ss lavatory pan wt.:1.880 mts; ss under slung tanks:2.200 mts approx; pvc copper cable: 1.523 mts approx ) .note: ( 1 ) cutting is permitted to loadable sizes. ( 2 ) the quantity of rc items mentioned for the above list will be arrived as per the joint handing over memo issued by the railway authorities to the successful bidder at the time of cutting / handing over of the lot and the same list of rc items should be returned to railways by the purchaser. ( 3 ) railways does not guarantee for quality and quantity description etc. ( 4 ) any non ferrous items ( other than aluminum ) , electrical items, rc items found in excess to the above, at the time of cutting and delivery of coach should be returned to railways. ( 5 ) successful bidders must ensure the rc items at the time of taking over and same should be returned to custodian before effecting delivery. in case which are not able to see / count / weight before dismantling and same may be jointly inspected and soon after dismantling the same will be recorded. ( 6 ) the purchaser is responsible for providing adequate safety fire fighting equipment on the spot at the time of cutting and delivery. ( 7 ) the purchaser has to remove / clear the muck, mud and zero value items released from the condmned coaches at the location to nominated area in crs / workshop before taking final delivery of the lot.loc: 11 coaches available back side of main store depot and 7 coaches available on mrs cutting yard. these 11 coaches will be moved to mrs cutting yard once the track is cleared.delivery on number basis only.total qty 18 numbers . pl no 98111048 ( 01 ) hsn code:72042990....

National Thermal Power Corporation Limited - Andhra Pradesh

33770381 procurement of nisiki fans for ups ntpc koldam and inverter cooling fans procurement of nisiki fans for ups ntpc koldam and inverter cooling fansfor ntpc simhadri. , cooling fans 4,230vac,50hz,fan1 ups ahs , fan6 230vac,50hz hirel ups , fan,8,230vac for 2x50kva ups , inverter cooling fan, p/n:181000084000 , inverter cooling fan, p/n:181000016000 => limited...

Road And Building Department - Andhra Pradesh

33765054 construction of court building and residential quarter at kurupam in vizianagaram district. sub work: providing balance electrical installation, networking and inverters to the above building....

Department of Higher Education - Andhra Pradesh

33752000 bids are invited for brushless dc motor drive setup , three phase, 7 level cascaded h bridge inverter , five phase pmsm motor with dc machine load setup , five phase three level npcinverter , four wheel e vehicle with pmsm and bldc and imdrive setup , auto transformersupply and installation of ac drives laboratory total quantity : 6...

South Central Railway - Andhra Pradesh

33679637 supply of 400 amps igbt inverter based manual metal400 amps igbt inverter based manual metal, 400 amps igbt inverter based manual metal arc welding machine to model no.tornado401 of ador fontech or equivalent models of fronious or esab ( full description at annexure 1 ) ...

Department of Higher Education - Andhra Pradesh

33638928 bids are invited for study of characteristics of scr,mosfet and igbt , study of single phase and three phase half and fully controlled bridge converter with r,rl and rle loads , study of single phase dual converter with r and rl loads , study of ac voltage controller using two thyristor anti parallel connected and triac with r and rl loads , study of dc dc converters , study of speed control of dc motor using h bridge converter , study of uni polar and bi polar pwm based single phaseinverter using controller , study of 3 phase pwm and nonpwm inverter using controller , study of speed control of 3phase inverter fed induction motor based on closed loop vby f slip speed control method using controller ,experimental setup to study the perfomance ofcycloconverter with r and rl loadssupply and installation of power electronics total quantity : 10...

Indian Navy - Andhra Pradesh

33626559 repair rate contract ( rrc ) for ups of cots equipment onboard enc ships 2 services 3 0.5 1.0 kva 4 repair of rectifier card 5 repair of static bypass switch / protection card 6 repair of inverter card 7 repair of charging board 8 repair of transformer 9 repair of mother board 10 repair of display / display board 11 repair of alarm unit 12 repair of cooling fan 13 repair of driver card 14 repair of dc converter 15 repair of bus relay card 16 1.1 2.0 kva 17 repair of rectifier card 18 repair of static bypass switch / protection card 19 repair of inverter card 20 repair of charging board 21 repair of transformer 22 repair of mother board 23 repair of display / display board 24 repair of alarm unit 25 repair of cooling fan 26 repair of driver card 27 repair of dc converter 28 repair of bus relay card 29 2.1 3.0 kva 30 repair of rectifier card 31 repair of static bypass switch / protection card 32 repair of inverter card 33 repair of charging board 34 repair of transformer 35 repair of mother board 36 repair of display / display board 37 repair of alarm unit 38 repair of cooling fan 39 repair of driver card 40 repair of dc converter 41 repair of bus relay card 42 3.1 5.0 kva 43 repair of rectifier card 44 repair of static bypass switch / protection card 45 repair of inverter card 46 repair of charging board 47 repair of transformer 48 repair of mother board 49 repair of display / display board 50 repair of alarm unit 51 repair of cooling fan 52 repair of driver card 53 repair of dc converter 54 repair of bus relay card 55 5.1 10 kva 56 repair of rectifier card 57 repair of static bypass switch / protection card 58 repair of inverter card 59 repair of charging board 60 repair of transformer 61 repair of mother board 62 repair of display / display board 63 repair of alarm unit 64 repair of cooling fan 65 repair of driver card 66 repair of dc converter 67 repair of bus relay card 68 10.1 20 kva 69 repair of rectifier card 70 repair of static bypass switch / protection card 71 repair of inverter card 72 repair of charging board 73 repair of transformer 74 repair of mother board 75 repair of display / display board 76 repair of alarm unit 77 repair of cooling fan 78 repair of driver card 79 repair of dc converter 80 repair of bus relay card 81 20.1 50 kva 82 repair of rectifier card 83 repair of static bypass switch / protection card 84 repair of inverter card 85 repair of charging board 86 repair of transformer 87 repair of mother board 88 repair of display / display board 89 repair of alarm unit 90 repair of cooling fan 91 repair of driver card 92 repair of dc converter 93 repair of bus relay card 94 second year 95 services 96 0.5 1.0 kva 97 repair of rectifier card 98 repair of static bypass switch / protection card 99 repair of inverter card 100 repair of charging board 101 repair of transformer 102 repair of mother board 103 repair of display / display board 104 repair of alarm unit 105 repair of cooling fan 106 repair of driver card 107 repair of dc converter 108 repair of bus relay card 109 1.1 2.0 kva 110 repair of rectifier card 111 repair of static bypass switch / protection card 112 repair of inverter card 113 repair of charging board 114 repair of transformer 115 repair of mother board 116 repair of display / display board 117 repair of alarm unit 118 repair of cooling fan 119 repair of driver card 120 repair of dc converter 121 repair of bus relay card 122 2.1 3.0 kva 123 repair of rectifier card 124 repair of static bypass switch / protection card 125 repair of inverter card 126 repair of charging board 127 repair of transformer 128 repair of mother board 129 repair of display / display board 130 repair of alarm unit 131 repair of cooling fan 132 repair of driver card 133 repair of dc converter 134 repair of bus relay card 135 3.1 5.0 kva 136 repair of rectifier card 137 repair of static bypass switch / protection card 138 repair of inverter card 139 repair of charging board 140 repair of transformer 141 repair of mother board 142 repair of display / display board 143 repair of alarm unit 144 repair of cooling fan 145 repair of driver card 146 repair of dc converter 147 repair of bus relay card 148 5.1 10 kva 149 repair of rectifier card 150 repair of static bypass switch / protection card 151 repair of inverter card 152 repair of charging board 153 repair of transformer 154 repair of mother board 155 repair of display / display board 156 repair of alarm unit 157 repair of cooling fan 158 repair of driver card 159 repair of dc converter 160 repair of bus relay card 161 10.1 20 kva 162 repair of rectifier card 163 repair of static bypass switch / protection card 164 repair of inverter card 165 repair of charging board 166 repair of transformer 167 repair of mother board 168 repair of display / display board 169 repair of alarm unit 170 repair of cooling fan 171 repair of driver card 172 repair of dc converter 173 repair of bus relay card 174 20.1 50 kva 175 repair of rectifier card 176 repair of static bypass switch / protection card 177 repair of inverter card 178 repair of charging board 179 repair of transformer 180 repair of mother board 181 repair of display / display board 182 repair of alarm unit 183 repair of cooling fan 184 repair of driver card 185 repair of dc converter 186 repair of bus relay card 187 third year 188 services 189 0.5 1.0 kva 190 repair of rectifier card 191 repair of static bypass switch / protection card 192 repair of inverter card 193 repair of charging board 194 repair of transformer 195 repair of mother board 196 repair of display / display board 197 repair of alarm unit 198 repair of cooling fan 199 repair of driver card 200 repair of dc converter 201 repair of bus relay card 202 1.1 2.0 kva 203 repair of rectifier card 204 repair of static bypass switch / protection card 205 repair of inverter card 206 repair of charging board 207 repair of transformer 208 repair of mother board 209 repair of display / display board 210 repair of alarm unit 211 repair of cooling fan 212 repair of driver card 213 repair of dc converter 214 repair of bus relay card 215 2.1 3.0 kva 216 repair of rectifier card 217 repair of static bypass switch / protection card 218 repair of inverter card 219 repair of charging board 220 repair of transformer 221 repair of mother board 222 repair of display / display board 223 repair of alarm unit 224 repair of cooling fan 225 repair of driver card 226 repair of dc converter 227 repair of bus relay card 228 3.1 5.0 kva 229 repair of rectifier card 230 repair of static bypass switch / protection card 231 repair of inverter card 232 repair of charging board 233 repair of transformer 234 repair of mother board 235 repair of display / display board 236 repair of alarm unit 237 repair of cooling fan 238 repair of driver card 239 repair of dc converter 240 repair of bus relay card 241 5.1 10 kva 242 repair of rectifier card 243 repair of static bypass switch / protection card 244 repair of inverter card 245 repair of charging board 246 repair of transformer 247 repair of mother board 248 repair of display / display board 249 repair of alarm unit 250 repair of cooling fan 251 repair of driver card 252 repair of dc converter 253 repair of bus relay card 254 10.1 20 kva 255 repair of rectifier card 256 repair of static bypass switch / protection card 257 repair of inverter card 258 repair of charging board 259 repair of transformer 260 repair of mother board 261 repair of display / display board 262 repair of alarm unit 263 repair of cooling fan 264 repair of driver card 265 repair of dc converter 266 repair of bus relay card 267 20.1 50 kva 268 repair of rectifier card 269 repair of static bypass switch / protection card 270 repair of inverter card 271 repair of charging board 272 repair of transformer 273 repair of mother board 274 repair of display / display board 275 repair of alarm unit 276 repair of cooling fan 277 repair of driver card 278 repair of dc converter 279 repair of bus relay card...

Indian Navy - Andhra Pradesh

33595373 tender for normal refit of in ship 1.0001 work pakage for nr in asset hull defect list 001 docking vessel to be docked in both versions. note 1: firms not to quote view docking, undocking and dock blocks preparation will be done by navy and the job is required to be carried out in navy premises ( i.e nd ( v ) slipway / drydock ) . note 2: last docked in version i on 04 oct 2018 1.0002 002 cleaning of under water hull and boot top area hp jet cleaning of entire under water area and boot top area ( with a pressure not exceeding 3000 psi ) remove the marine growth / barnacles and prepare for survey. note: ( i ) u / w area: 415 including boot top 1.0003 003 cleaning of internal compartments fw tanks ( 06 nos ) manually clean fuel tanks free of accumulated fuel and residual muck and present for survey. 1.0004 004 cleaning of internal compartments manually clean following internal compartments free of accumulated water and residual muck and present for survey. ( a ) cable locker 1.0005 004 cleaning of internal compartments manually clean following internal compartments free of accumulated water and residual muck and present for survey. ( b ) forepeak tank 1.0006 004 cleaning of internal compartments manually clean following internal compartments free of accumulated water and residual muck and present for survey. ( c ) cofferdam 1.0007 004 cleaning of internal compartments manually clean following internal compartments free of accumulated water and residual muck and present for survey ( d ) bosun store, naval store and paint store 1.0008 005 cleaning of internal compartments manually clean fresh water gravity tank for free of accumulated water and residual muck and present for survey. 1.0009 006 cleaning of internal compartments manually clean sea water gravity tank for free of accumulated water and residual muck and present for survey. 1.001 007 cleaning of internal compartments manually clean following internal compartments free of accumulated oily water and grime / muck and present for survey: ( g ) pump room ( bilges: 120 sqm, bulkheads: 95 sqm ) 1.0011 008 cleaning of internal compartments asp manually clean following internal compartments free of accumulated oily water and grime / muck and present for survey: steering gear room ( bilges: 24 sqm, bulkheads:76 sqm ) 1.0012 009 cleaning of above water area hp jet cleaning of entire above water area ( with pressure not exceeding 3000 psi ) remove the dirt and salt contamination 1.0013 010 cleaning of super strcture hp jet cleaning of entire super strcture arae ( with pressure not exceeding 3000 psi ) remove the dirt and salt contamination 1.0014 011 cleaning of weather deck hp jet cleaning of entire weather deck ( with pressure not exceeding 3000 psi ) remove the dirt and salt contamination 1.0015 012 hull survey external and internal structures ( a ) hull survey. carry out visual and hammer survey in accordance with no 01 / 15 of under water hull , boot top area, above water hull, super structure, weather decks and all internal compartments ( i.e. fw tanks, ballast tanks, fore peak tank, engine room, steering compartment, fo tanks, cofferdams, all stiffeners and deck fittings etc. ) all manholes to be inspected for water tightness, chalk impression test to be carried out. note: ( i ) ls for survey ( ii ) firm to submit 07 copies of hull survey report . 1.0016 013 utg survey carry out utg survey in thge presence of qc representatives of u / w hull, ship side, superstrcture, weather deck, bulkheads, tanks, living spaces covering entire part of hull. firm to submit 07 copies of hull survey report. 1.0017 014 steel renewal quote for steel renewal at various locations as per survey report note : quoted repair cost shall include cost of both sides blasted and primed is 2062 grade `b’ quality steel. degutting / regutting / renewal of all obstructions in way of steel renewals including lagging / panelling, minor fittings / equipments with their foundations, ventilation systems, staging etc., as indicated by survey team / rmt, proving of the weld runs by non destructive tests and by hose test on completion of welding, pressure testing and proving of tanks where steel renewal was undertaken etc. 1.0018 015 build ups ( a ) carry out build ups as indicated by the hull survey team / surveyor size 25 x 25 mm 1.0019 015 build ups ( b ) carry out build ups as indicated by the hull survey team / surveyor size 50 x 50 mm 1.002 016 fairing of deformed structure carryout fairing of deformed structures as indicated by hull survey team / surveyor 1.0021 017 re welding carry out re welding runs on weld seams as indicated by hull survey team / qc / rmt. 1.0022 018 draft marks draught marks corroded / eaten away, to be renewed and painted. both roman and numeric. 1.0023 019 sacrificial anodes ( a ) renew sacrificial anodes those consumed more than 50% type: mk i note: anodes will be supplied by navy / coy. 1.0024 019 sacrificial anodes ( b ) renew sacrificial anodes those consumed more than 50% type: mk vi note: anodes will be supplied by navy / coy. 1.0025 020 surface preparation under water area surface preparation to sa 2.5 std using grit blasting on paint damaged areas / renewed plate areas as per the paint oem rep recommendation for paint application. 1.0026 021 painting under water area jotun scheme. paint under water area with following paint scheme. note: quoted repair cost shall be inclusive of cost of paints also. ( a ) 1st coat: primer penguard primer 50 microns 1.0027 021 painting under water area jotun scheme. paint under water area with following paint scheme. note: quoted repair cost shall be inclusive of cost of paints also. ( b ) 2nd coat: anti corrosive jotacote universal ( aluminium ) 150 microns 1.0028 021 painting under water area jotun scheme. paint under water area with following paint scheme. note: quoted repair cost shall be inclusive of cost of paints also. ( c ) 3rd coat: anti corrosive jotacote universal ( grey ) 150 microns 1.0029 021 painting under water area jotun scheme. paint under water area with following paint scheme. note: quoted repair cost shall be inclusive of cost of paints also. ( d ) 4th coat: tie coat: safeguard es 125 microns 1.003 021 painting under water area painting jotun scheme. paint under water area with following paint scheme. note: quoted repair cost shall be inclusive of cost of paints also. ( e ) 5th coat: a / f: seaquantum ultra ( brown / light red ) 150 microns 1.0031 021 painting under water area jotun scheme. paint under water area with following paint scheme. note: quoted repair cost shall be inclusive of cost of paints also. ( f ) 6th coat: a / f: seaquantum ultra ( red brown / dark red ) 150 microns 1.0032 021 painting under water area jotun scheme. paint under water area with following paint scheme. note: quoted repair cost shall be inclusive of cost of paints also. ( g ) 7th coat: a / f: seaquantum ultra ( brown / light red ) 150 microns 1.0033 021 painting boot top area jotun scheme. paint boot top area with following paint scheme. note: quoted repair cost shall be inclusive of cost of paints also. ( h ) 8th coat: a / f: seaquantum ultra ( black ) 150 microns dft 1.0034 022 surface prepartion above water area and bulwark including guardrails carry out surface prepartion to sa2.5 using grit blasting standard for paint application as per survey report by paint oem rep 1.0035 023 painting above water area and bulwark including guardrails jotun scheme. paint above water area with following paint scheme.note: quoted repair cost shall be inclusive of cost of paints also ( a ) 1st coat: penguard primer 50 microns dft 1.0036 023 painting above water area and bulwark including guardrails jotun scheme. paint above water area with following paint scheme.note: quoted repair cost shall be inclusive of cost of paints also ( b ) 2nd coat: jotamastic 80 ( grey / red brown ) 125 microns dft 1.0037 023 painting above water area and bulwark including guardrails jotun scheme. paint above water area with following paint scheme.note: quoted repair cost shall be inclusive of cost of paints also ( c ) 3rd coat: jotamastic 80 ( grey / red brown ) 125 microns dft 1.0038 023 painting above water area and bulwark including guardrails jotun scheme. paint above water area with following paint scheme.note: quoted repair cost shall be inclusive of cost of paints also ( d ) 4th coat: hard top xp grey 60 microns dft 1.0039 024 surface prepartion super structure and deck fittings carry out surface prepartion to st3 standard for paint application as per survey report by paint oem rep . 1.004 025 painting super structure and deck fittings jotun scheme. paint superstructure area with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also. ( a ) 1st coat: primer penguard primer 50 microns dft 1.0041 025 painting super structure and deck fittings jotun scheme. paint superstructure area with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also ( b ) 2nd coat: jotamastic 80 ( red ) 125 microns dft 1.0042 025 painting super structure and deck fittings jotun scheme. paint superstructure area with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also ( c ) 3rd coat: jotamastic 80 ( grey ) 125 microns dft 1.0043 025 painting super structure and deck fittings jotun scheme. paint superstructure area with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also ( d ) 4th coat: hard top xp grey 7040 60 microns dft 1.0044 026 surface prepartion weather decks carry out hydro jet blasting of entire weather deck, bridge deck and flag deck to wj 2 standards. 1.0045 027 painting paint weather decks jotun scheme. paint weather decks with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also. ( a ) 1st coat: primer penguard primer 50 microns dft 1.0046 027 painting paint weather decks jotun scheme. paint weather decks with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also. ( b ) 2nd coat: jotamastic 87 150 microns dft 1.0047 027 painting paint weather decks jotun scheme. paint weather decks with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also. ( c ) 3rd coat: jota armour 800 microns dft 1.0048 028 surface prepartion internal compartments fore peak tank, cable locker, bosun store , naval store , paint store and cofferdam carry out mechanical cleaning to st 3 standard as per survey report of paint oem for fore peak tank , cable locker and cofferdam ( 04 ) . 1.0049 029 painting fore peak tank, cable locker, bosun store , naval store , paint store and cofferdam jotun scheme. paint fore peak tanks, ballast tanks and cable locker with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also. ( a ) 1st coat: primer penguard primer 50 microns dft 1.005 029 painting fore peak tank, cable locker, bosun store , naval store , paint store and cofferdam jotun scheme. paint fore peak tanks, ballast tanks and cable locker with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also ( b ) 2nd coat: anticorrosive balloxy hb light ( bieze ) 150 microns 1.0051 029 painting fore peak tanks, ballast tanks and cable locker jotun scheme. paint fore peak tanks, ballast tanks and cable locker with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also ( c ) 3rd coat: anticorrosive balloxy hb light ( grey ) 150 microns 1.0052 030 surface prepartion internal compartments bilges of pump room and asp compartment including bulkheds carry out mechanical cleaning to st 3 standard as survey report of paint oem for paint application. ( i ) pump room & asp ( bilges 315 sqm, ) 1.0053 031 painting machinery bilges jotun scheme. paint bilges of pump room and asp compartment with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also. ( a ) 1st coat: primer penguard primer 50 microns dft 1.0054 031 painting machinery bilges jotun scheme. paint bilges of pump room and asp compartment with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also. ( b ) 2nd coat: anticorrosive jotacote universal ( aluminium ) 150 microns 1.0055 031 painting machinery bilges jotun scheme. paint bilges of pump room and asp compartment with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also. ( c ) 3rd coat: anticorrosive jotacote universal ( grey ) 150 microns 1.0056 031 painting machinery bilges jotun scheme. paint bilges of pump room and asp compartment with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also. ( d ) 4th coat: penguard top coat 50 microns. 1.0057 032 painting bulkheads of pump room and asp jotun scheme. paint bulkheads and deckheads of pump room and asp compartments with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also. ( a ) 1st coat: primer penguard primer 50 microns dft 1.0058 032 painting bulkheads of pump room and asp jotun scheme. paint bulkheads and deckheads of pump room and asp compartments with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also. ( b ) 2nd coat: interior fire retardent paint 100 microns 1.0059 032 painting bulkheads of pump room and asp jotun scheme. paint bulkheads and deckheads of pump room and asp compartments with following paint scheme: note: quoted repair cost shall be inclusive of cost of paints also. ( c ) 3rd coat: interior fire retardent paint 100 micron 1.006 033 cleaing of ru tanks cleaning of fuel oil ru tanksmanually scrap and clean to bare metal and apply two coats of om 750 oil in following tanks: fuel oil ru tanks ( 02nos ) note: quoted cost shall be inclusive of cost of oil also. 1.0061 034 surafce prepartion bulkheads, decks and dadoes of internal compartments carry out mechanical cleaning of ( deck store, rec room , prov store and crew room stores, battery stores, co2 room, paint stores, pump store, deck store and eletrical control room ) to st 3 standard as survey report of paint oem for paint application. 1.0062 035 painting internal compartments decks and dadoes jotun scheme. carry out painting of internal compartments decks and dadoes at following locations: naval store, battery store, co2 room, paint store, pump store, deck store and eletrical control room. ( a ) 1st coat: primer penguard 1x50 microns 1.0063 035 painting internal compartments decks and dadoes jotun scheme. carry out painting of internal compartments decks and dadoes at following locations: naval store, battery store, co2 room, paint store, pump store, deck store and eletrical control room. ( b ) 2nd coat : jotamastic 80 grey 1 x 150 microns 1.0064 035 painting internal compartments decks and dadoes jotun scheme. carry out painting of internal compartments decks and dadoes at following locations: naval store, battery store, co2 room, paint store, pump store, deck store and eletrical control room. ( c ) 3rd coat ; burnswick green finishing paint 100 microns 1.0065 036 painting internal compartments bulkheads jotun scheme. carry out painting of internal compartments bulkheads and deck heads area at following locations: naval store, battery store, co2 room, paint store, pump store, deck store and eletrical control room. ( a ) 1st coat: primer penguard 1x50 microns 1.0066 036 painting internal compartments bulkheads jotun scheme. carry out painting of internal compartments bulkheads and deck heads area at following locations: naval store, battery store, co2 room, paint store, pump store, deck store and eletrical control room. note: quoted repair cost shall be inclusive of cost of paints also. ( b ) 1st coat: interior fire retardent paint 100 microns 1.0067 036 painting internal compartments bulkheads jotun scheme. carry out painting of internal compartments bulkheads and deck heads area at following locations: naval store, battery store, co2 room, paint store, pump store, deck store and eletrical control room. note: quoted repair cost shall be inclusive of cost of paints also. ( c ) 2nd coat: interior fire retardent paint 100 microns 1.0068 037 surface preaprtion fw tanks carry out surface preaprtion to st 3 standards of fw tanks as survey report of paint oem for paint application. 1.0069 038 painting fw tanks jotun paint scheme paint all sullage tanks with following paint scheme: ( a ) penguard hb 100 microns 1.007 038 painting fw tanks jotun paint scheme paint all sullage tanks with following paint scheme: ( b ) penguard hb 100 microns 1.0071 038 painting fw tanks jotun paint scheme paint all sullage tanks with following paint scheme: ( c ) penguard hb 100 microns 1.0072 039 anchor and anchor chain cable. anchor and anchor chain cable and associated fittings are to be hydro jet blasted to bare metal, eased for free movement and to present for survey at ndv / mfab dept. paint with black bituminous paint post survey iaw no 12 / 2001 and refit back. note : the job involves removal of anchors, chain cables and accessories, laying out for cleaning, painting and refitment. ( a ) anchors 03 1.0073 039 anchor and anchor chain cable. anchor and anchor chain cable and associated fittings are to be hydro jet blasted to bare metal, eased for free movement and to present for survey at ndv / mfab dept. paint with black bituminous paint post survey iaw no 12 / 2001 and refit back. ( b ) chain cable ( dia 17.5mm ) ( i ) full shackles 08 ( ii ) half shackles 04 1.0074 039 anchor and anchor chain cable. anchor and anchor chain cable and associated fittings are to be hydro jet blasted to bare metal, eased for free movement and to present for survey at ndv / mfab dept. paint with black bituminous paint post survey iaw no 12 / 2001 and refit back. ( c ) swivel piece 1.0075 039 anchor and anchor chain cable. anchor and anchor chain cable and associated fittings are to be hydro jet blasted to bare metal, eased for free movement and to present for survey at ndv / mfab dept. paint with black bituminous paint post survey iaw no 12 / 2001 and refit back. ( d )  lug less joining shackles 1.0076 039 anchor and anchor chain cable. anchor and anchor chain cable and associated fittings are to be hydro jet blasted to bare metal, eased for free movement and to present for survey at ndv / mfab dept. paint with black bituminous paint post survey iaw no 12 / 2001 and refit back. ( e ) d shackles 1.0077 039 anchor and anchor chain cable. anchor and anchor chain cable and associated fittings are to be hydro jet blasted to bare metal, eased for free movement and to present for survey at ndv / mfab dept. paint with black bituminous paint post survey iaw no 12 / 2001 and refit back. ( f ) chain stopper / compressor 1.0078 040 anchor windlass completely strip & overhaul anchor windlass, renew brake linings, refit and prove for satisfactory operation. quoted price to include cost of liners and spares also. 1.0079 041 bollards ( b ) bollards and foundatiosn corroded and thinned. to be repaired / renewed as per hull survey report. doubler plate area 420mmx420mm, dia of pipe 219.1mm, height 1460mm, foundation area 400mmx400mmx90mm, thickness of plate 10mm towing gear securing rod dia 50mm. 1.008 042 guardrails ( a ) fixed verticals guardrail stanchions on weather deck deformed / bent from deck. to be renewed. ( mat ms angle bar ) 1.0081 042 guardrails ( b ) fixed horizontal guardrails on weather deck deformed / bent to be renewed. ( mat ms ) 1.0082 043 metallilc chain guardrails metallic chain guardrails of stanchions corroded to chipped and cleaned. renewal cost should include cost of material also. 1.0083 044 sanitry sysytem soil pipes to be removed, chemically cleaned, pressure tested and fitted back in situ. mat: ms , dia: 04inch. ( pressure: 3kg / cm2 ) 1.0084 045 ventilation ( a ) mushroom type natural exhaust ventilator to be removed, cleaned / overhauled and fitted back. ventilator mesh to be renew. prove for satisfactory operation. details mush room head dia 500 mm, height 1550 mm 1.0085 045 ventilation ( b ) mushroom type forced supply ventilator to be removed, cleaned / overhauled and fitted back. ventilator mesh to be renew. prove for satisfactory operation. details mush room head dia 370 mm, height 1550 mm, 1.0086 046 drainage system drain pipe leading from mast deck to 01 deck and no. 1 deck to engine room corroded, thinned and holed, to be renewed. mat: gi, 03 inch dia. 1.0087 047 sanitry system sanitry fittingss in crew bathrooms and wc. ( a ) ss wash basin to be renewed. note: quoted cost shall include cost all items / spares. ( a ) wash basin 1.0088 047 sanitry system sanitry fittingss in crew bathrooms and wc. sanitry fittings in crew bathrooms and wc to be renewed. ( b ) provision ss tap: 1 / 2 inch 1.0089 047 sanitry system sanitry fittingss in crew bathrooms and wc. ( c ) ss supply pipeline broken / damaged to be renewed. mat : cu ni, dia: ½ inch 1.009 047 sanitry system sanitry fittingss in crew bathrooms and wc. ( d ) drain pipeline broken / damaged to be renewed. mat ms, dia 2 inch 1.0091 047 sanitry system sanitry fittingss in crew bathrooms and wc. ( e ) wc ( mat ceramic ) and flush valves to be renewed. mat brass, dia 2 1.0092 048 fresh water system crew bathrooms and wc. .note: quoted cost shall include cost all items / spares. ( a ) ss stop cock 1’’ to be renewed 1.0093 048 fresh water system crew bathrooms and wc. ( b ) shower head to be fitted in bathrooms note: quoted repair cost shall include cost all items / spares. 1.0094 049 tyre fenders tyre fender damaged on p&s side , to be renwed with used automobile tyre fenders moulded with 8 mm white natural rubber. mat rubber, colour white . no painting or coating of any other form will be permitted. vendors to adhere to sow ( a ) od 750mm; id 450 mm , width 250 mm 1.0095 049 tyre fenders provision of securing arrangment in all tyre fenders for fitment on ship side. ( b ) chain securing brackets / deck eyes. 1.0096 049 tyre fenders provision of securing arrangment in all tyre fenders for fitment on ship side ( c ) provission of securing chain. 16 mm dia for tyre fenders 1.0097 049 tyre fenders provision of securing arrangment in all tyre fenders for fitment on ship side ( d ) bush for passing chain on tyres. 1.0098 049 tyre fenders provision of securing arrangment in all tyre fenders for fitment on ship side ( e ) provision of d shackles for tyre fenders 1.0099 050 d shape fenders ( a ) d shaped rubber fenders damaged / perished to be renewed. color grey / white length 1000 mm length location 35 on shipside and 05 on transom material epdm rubber as per nes170 1.01 050 d shape fenders securing brackets ( b ) fender securing flat bar brackets to be repaired / renewed as necessasry. ( mat ms ) . size : 1100mm x 110mm x 08mm 1.0101 050 d shape fenders securing brackets ( c ) fender securing c clamp brackets to be repaired / renewed as necessasry. ( mat ms ) . size : 200mm x 110mm x 08mm 1.0102 051 sky light ss butterfly nuts and tumbler bolt of engine room sky light &exhaust flaps broken. to be renewed. dia of bolt : 10 mm & 6 inch length ( mat ms ) . 1.0103 054 rubber beading rubber beading of following doors, hatch and skylight perished / cracked to be renewed and chalk test to be proved. ( epdm rubber with shore hardness 50 + 5o a ) ( a ) wt door 1.0104 051 rubber beading rubber beading of following doors, hatch and skylight perished / cracked to be renewed and chalk test to be proved. ( epdm rubber with shore hardness 50 + 5o a ) ( b ) wt hatch 1.0105 052 apt air pressure test of the following tanks to be undertaken and rectify the defects if any observed during pressure testing and prove to 0.14 kg / cm2. note: apt and proving of those tanks wherein steel renewal undertaken as part of steel renewal dl. 0003 ( c ) above is that of firms liability with no additional cost and those tanks where no steel renewals undertaken only would be considered for payment as per the indicated rates under this dl. serial. ( a ) forepeak tanks 1.0106 052 apt air pressure test of the following tanks to be undertaken and rectify the defects if any observed during pressure testing and prove to 0.14 kg / cm2. note: apt and proving of those tanks wherein steel renewal undertaken as part of steel renewal dl. 0003 ( c ) above is that of firms liability with no additional cost and those tanks where no steel renewals undertaken only would be considered for payment as per the indicated rates under this dl. serial. ( b ) fw tanks 1.0107 052 apt air pressure test of the following tanks to be undertaken and rectify the defects if any observed during pressure testing and prove to 0.14 kg / cm2. note: apt and proving of those tanks wherein steel renewal undertaken as part of steel renewal dl. 0003 ( c ) above is that of firms liability with no additional cost and those tanks where no steel renewals undertaken only would be considered for payment as per the indicated rates under this dl. serial. ( c ) void space and cofferdam 1.0108 052 apt air pressure test of the following tanks to be undertaken and rectify the defects if any observed during pressure testing and prove to 0.14 kg / cm2. note: apt and proving of those tanks wherein steel renewal undertaken as part of steel renewal dl. 0003 ( c ) above is that of firms liability with no additional cost and those tanks where no steel renewals undertaken only would be considered for payment as per the indicated rates under this dl. serial. ( d ) cable locker 1.0109 053 bilge paltform ( a ) renew bilge platform plate. material aluminium chequerd plate, thickness 05 mm 1.011 053 bilge platform ( b ) supporting brackets to be renewed where ever required ( mat ms ) . securing nut&bolts to be of mat ss. 1.0111 054 cleats ms cleats perished / thinned to be renewed ( size 28 mm ) . quote shall includes nuts bolts and associated accessories 1.0112 055 ventilation system ( a ) breather pipes of various tanks on upper deck corroded and thinned including wire mesh, to be repaired / renewed. ( mat. gi pipe ) pipe dia 2 1 / 2 inch 1.0113 055 ventilation system ( b ) deck distance piece and flanges corroded to be renewed including rubber joints. dia 150mm 1.0114 055 ventilation system ( c ) ventilation trunking wire mesh to be renewed at damaged areas. size: 400mmx600mm 1.0115 056 deck underlay dry compatments deck underlay ( macrotech ) to be repaired / renewed at uprooted / damaged / steel renewed, accommodation areas, wheel house and alleways. ( a ) surface preparation and application of erop. and mass 98. 1.0116 056 deck underlay dry compatments deck underlay ( macrotech ) to be repaired / renewed at uprooted / damaged / steel renewed, accommodation areas, wheel house and alleways.. ( b ) surface preparation to be carried out by buffing on mass 98 and application of mass 96. 1.0117 056 deck underlay dry compatments deck underlay ( macrotech ) to be repaired / renewed at uprooted / damaged / steel renewed, accommodation areas, wheel house and alleways.. ( c ) surface preparation and application of sealer coat on entire area 1.0118 057 deck underlay wet compartments deck underlay ( macrotech ) to be repaired / renewed in bathrooms at uprooted / damaged / steel renewed. ( a ) surface preparation and application of erop. and mass 98. 1.0119 057 deck underlay wet compartments deck underlay ( macrotech ) to be repaired / renewed in bathrooms at uprooted / damaged / steel renewed. ( b ) surface preparation to be carried out by buffing on mass 98 and application of mass 96. 1.012 057 deck underlay wet compartments deck underlay ( macrotech ) to be repaired / renewed in bathrooms at uprooted / damaged / steel renewed. ( c ) surface preparation and application of sealer coat on entire area 1.0121 058 deck underlay dadoe area deck underlay ( macrotech ) to be repaired / renewed in bathrooms. ( a ) surface preparation and application of erop. and mass 98. 1.0122 058 deck underlay dadoe area deck underlay ( macrotech ) to be repaired / renewed in bathrooms. ( b ) surface preparation to be carried out by buffing on mass 98 and application of mass 96. 1.0123 058 deck underlay dadoe area deck underlay ( macrotech ) to be repaired / renewed in bathrooms. ( c ) surface preparation and application of sealer coat on entire area 1.0124 059 wt hatches wt hatch clips to be removed, cleaned, greased and refitted wt hatch ( 0.6m x 0.6m ) 1.0125 059 wt doors wt door clips to be removed, cleaned, greased and refitted wt doors 1.0126 060 nwt nwt wooden door of wheel house perished, to be repaired / renewed including cylindrical door lock. 1.0127 061 manhole rubber joints perished, to be renewed ( a ) joints 1.0128 061 manhole ( b ) studs of manholes perished, to be renewed ( only defective studs to be renewed as per survey report ) ms studs with nut, size 20 mm 1.0129 061 manhole ( c ) manhole covers corroded / thinned. to be renewed. mat is 2062 grade b steel. size 2 x 1.5 1.013 062 locking arrangment ( a ) mortise locks in accomodation areas defective to be renewed. 1.0131 062 locking arrangment ( b ) ms hasp staple / locking arrangemet on ms door and hatches corroded / broken / damaged to be renewed as per sample fitted. 1.0132 063 name board following name board perished / damaged, to be renewed / repaired. ( a ) repair / renewal of vessel name board including electroplating to be carried out on ship side 02 1.0133 063 name board following name board perished / damaged, to be renew. ( b ) vessel illuminated board with perspex sheet 01 1.0134 063 name board following name board perished / damaged, to be renew. ( c ) painting of vessel name on bulwark / ship side in both hindi and english with fluorescent paint 02 1.0135 064 furniture ( a ) crca kit lockers perished , to be renewed ( 90x80x45 cm ) 1.0136 064 furniture ( b ) crca standing lockers perished, to be renewed ( 183x40x45 cm ) 1.0137 064 furniture ( c ) wooden table damaged / pershed to be renewed 1.0138 064 furniture ( d ) wooed paneling in crew rest room and wheel house damged / perished, to be renewed 1.0139 065 gantry wire rope overhauling of gantry on weather deck to be carried out. steel wire rope to be load tested with swl of 01 ton. 1.014 066 awning repair of damaged awning shade frame wether deck at 02 locations of gi pipes and fitment of the same on fwdand aft a ) size: 2m x 5.5 m approx. mat: gi pipe 1.0141 067 pvc awning pvc awning at foxle and at aft side renewel of pvc awning over the frame using securing rope. mat as per sample. 1.0142 engineering work package 1001, d.g set engine, make: kirlosker oil engine ltd, model:ha294 19bhp@1500rpm air cooled 12v start cum hand start. total running hours 75 hrs, ( 1000 hrly routine carried out on the da during sr 17 ) . following to be carried out: ( firm not to quote ) 1.0143 1001, d.g set engine, make: kirlosker oil engine ltd, model:ha294 19bhp@1500rpm air cooled 12v start cum hand start. ( a ) engine lub oil to be changed ( oil to be supply by firm ) .oil servo 15 w 40 1.0144 1001, d.g set engine, make: kirlosker oil engine ltd, model:ha294 19bhp@1500rpm air cooled 12v start cum hand start. ( b ) fuel filter, insert micro filter element / cartridge to be changed.firm to quote for spares / material required. 1.0145 1001, d.g set engine, make: kirlosker oil engine ltd, model:ha294 19bhp@1500rpm air cooled 12v start cum hand start. ( c ) lub oil filter element / cartridge to be changed.firm to quote for spares / material required. 1.0146 1001, d.g set engine, make: kirlosker oil engine ltd, model:ha294 19bhp@1500rpm air cooled 12v start cum hand start. ( d ) injectors to be renewed.firm to quote for spares / material required. 1.0147 1001, d.g set engine, make: kirlosker oil engine ltd, model:ha294 19bhp@1500rpm air cooled 12v start cum hand start. ( e ) change intake air filtering unit 1.0148 1001, d.g set engine, make: kirlosker oil engine ltd, model:ha294 19bhp@1500rpm air cooled 12v start cum hand start. ( f ) flexible hoses fitted for lub oil and fuel oil system to be renewed 1.0149 1001, d.g set engine, make: kirlosker oil engine ltd, model:ha294 19bhp@1500rpm air cooled 12v start cum hand start. ( g ) carry out adjustment of overhead set. ( tappet setting of injectors & valves ) . 1.015 1001, d.g set engine, make: kirlosker oil engine ltd, model:ha294 19bhp@1500rpm air cooled 12v start cum hand start. ( h ) remove & chemical clean lub oil cooler & fresh water cooler. carry out pressure testing of lub oil cooler and fresh water cooler.renew all gasket & o rings. 1.0151 1001, d.g set engine, make: kirlosker oil engine ltd, model:ha294 19bhp@1500rpm air cooled 12v start cum hand start. ( j ) performance trials of the engine to be carried out. 1.0152 1002, fresh water cargo pump, make be pumps model ma 1023kk dgs2 316 ms3, ( a ) cargo fresh water pumps not developing sufficient pressure, pumps to be overhauled. ( overhaul to includes change of seals, gaskets, bearings, impeller , joints and other consumables ) 1.0153 1002, fresh water cargo pump, make be pumps model ma 1023kk dgs2 316 ms3, ( b ) suction and discharge pressure gauges along with end fittings and gauge lines to be renewed. ( range 0 10 kg / cm2, cuni lines 10 rmt ) 1.0154 1002, fresh water cargo pump, make be pumps model ma 1023kk dgs2 316 ms3, ( c ) pumps to be proved for satisfactory operation. 1.0155 1003, prime mover for cargo fresh water pump, make kirloskar oil engines, model ha294, sr no e1 03.1021.10 / 1300044, 1300045, 1300046, rpm 1800, qty 03, bhp 19 bhp@1500rpm. ( a ) engine lub oil to be changed. oil to be supply by firm ) .oil servo 15 w 40 1.0156 1003, prime mover for cargo fresh water pump, make kirloskar oil engines, model ha294, sr no e1 03.1021.10 / 1300044, 1300045, 1300046, rpm 1800, qty 03, bhp 19 bhp@1500rpm. ( b ) fuel filter, insert micro filter element / cartridge to be changed. firm to quote for spares / material required. 1.0157 1003, prime mover for cargo fresh water pump, make kirloskar oil engines, model ha294, sr no e1 03.1021.10 / 1300044, 1300045, 1300046, rpm 1800, qty 03, bhp 19 bhp@1500rpm. ( c ) lub oil filter element / cartridge to be changed. firm to quote for spares / material required. 1.0158 1003, prime mover for cargo fresh water pump, make kirloskar oil engines, model ha294, sr no e1 03.1021.10 / 1300044, 1300045, 1300046, rpm 1800, qty 03, bhp 19 bhp@1500rpm. ( d ) injectors to be renewed.firm to quote for spares / material required. 1.0159 1003, prime mover for cargo fresh water pump, make kirloskar oil engines, model ha294, sr no e1 03.1021.10 / 1300044, 1300045, 1300046, rpm 1800, qty 03, bhp 19 bhp@1500rpm. ( e ) carry out adjustment of overhead set. ( tappet setting of injectors & valves ) . 1.016 1003, prime mover for cargo fresh water pump, make kirloskar oil engines, model ha294, sr no e1 03.1021.10 / 1300044, 1300045, 1300046, rpm 1800, qty 03, bhp 19 bhp@1500rpm. ( f ) change intake air filtering unit 1.0161 1003, prime mover for cargo fresh water pump, make kirloskar oil engines, model ha294, sr no e1 03.1021.10 / 1300044, 1300045, 1300046, rpm 1800, qty 03, bhp 19 bhp@1500rpm. ( g ) performance trials of the engine to be carried out. 1.0162 1004, following system pipes to be removed , chemically cleaned , pressure tested and fitted back ( a ) fresh water, system size 50 mm, mat ms 1.0163 1004, following system pipes to be removed , chemically cleaned , pressure tested and fitted back ( b ) fuel water, system size 20 mm, mat ms 1.0164 1004, following system pipes to be removed , chemically cleaned , pressure tested and fitted back ( c ) auxialiary system pipes size 50 mm, mat ms 1.0165 1004, following system pipes to be removed , chemically cleaned , pressure tested and fitted back ( d ) exhaust system pipes size 25 mm mat ms 1.0166 1005, following system pipes to be renewed. ( a ) fresh water, system size 50 mm, mat ms 1.0167 1005, following system pipes to be renewed. ( b ) fuel water, system size 20 mm, mat ms 1.0168 1005, following system pipes to be renewed. ( c ) auxialiary system pipes size 50 mm, mat ms 1.0169 1005, following system pipes to be renewed. d ) exhaust system pipes size 25 mm mat ms 1.017 1006, miscellenious ( a ) fresh water system valves to be overhauled, including renewal of wear down parts ( spindle disc ) . type screw down, dia 80 mm 1.0171 1006, miscellenious ( b ) fresh water system valve wheel and cocks corroded. to be manufactured as per sample mat ms 1.0172 1006, miscellenious ( c ) fire system hydrants internal thread perished. to be manufactured as per sample. mat brass. 1.0173 1006, miscellenious ( d ) hand pumps not taking suction. to be overhauled and proved for operation 1.0174 1006, miscellenious ( e ) fuel filling point adaptors to be manufactured as per sample, material brass 1.0175 1006, miscellenious ( f ) hot lagging to be renewed for exhaust lines of dg & all pumps. 1.0176 1007, dd fresh water pump starting panel 12 v dc overhaul and routine to be carried out and proved for satisfectory performance 1.0177 1008 rudder & steering system ( a ) wire & pulley arrangement from wheel house to rudder stock to check for proper operation. pulley and wire to greased and eased up. 1.0178 1008 rudder & steering system ( b ) rudder & rudder stock jammed, to be eased and made operational 1.0179 1008 rudder & steering system ( c. ) fabricate geared wheel provided ( as sample ) for rudder movement from wheel house 1.018 electricla work package 2001, main switch board 415v, 3ph, 50 hz ( a ) overhauling of switchboard to be carried out including renewal of defective control wiring, defective fuse link and fuse carrier, terminal blocks, crimping of perished lugs of control wiring, perished number sleeves to be replaced, defective indication lamps to be changed. 1.0181 2001, main switch board 415v, 3ph, 50 hz ( b ) following meters to be renewed. ( firm not to quote ) 1.0182 2001, main switch board 415v, 3ph, 50 hz ( b ) following meters to be renewed ( i ) voltmeter 0 500v 1.0183 2001, main switch board 415v, 3ph, 50 hz ( b ) following meters to be renewed ( ii ) ammeter 0 100a 1.0184 2001, main switch board 415v, 3ph, 50 hz ( b ) following meters to be renewed ( iii ) frequency meter 45 50 55 hz 1.0185 2001, main switch board 415v, 3ph, 50 hz ( c ) following mccb to be renewed. ( firm not to quote ) 1.0186 2001, main switch board 415v, 3ph, 50 hz ( c ) following mccb to be renewed ( i ) hand operated mccb rating : 415v, 3phase, 50 hz, make : schneider, model : ezc 100n 40a 1.0187 2001, main switch board 415v, 3ph, 50 hz ( c ) following mccb to be renewed ( ii ) hand operated mccb rating : 415v, 3phase, 50 hz, make : schneider, model : ezc 100n 80a 1.0188 2001, main switch board 415v, 3ph, 50 hz ( d ) mechanical cleaning of main switchboard panel board to be carried & painted with one coat of primer and one coat of enamle paint ( white color paint from inside and gray color paint from outside ) . 1.0189 2002, eqpt / system: generators / alternator make:kirlosker, 415v, 3ph, 20kva, 50hz, 1500rpm carryout routines mentioned below and prove them for satisfactory performance. ( routine may be carried out with assistance of oem or authorised rep ) . ( firm not to quote ) 1.019 2002, eqpt / system: generators / alternator make:kirlosker, 415v, 3ph, 20kva, 50hz, 1500rpm carryout routines mentioned below and prove them for satisfactory performance. ( routine may be carried out with assistance of oem or authorised rep ) . ( a ) overhaul the generators / alternator 1.0191 2002, eqpt / system: generators / alternator make:kirlosker, 415v, 3ph, 20kva, 50hz, 1500rpm carryout routines mentioned below and prove them for satisfactory performance. ( routine may be carried out with assistance of oem or authorised rep ) . ( b ) renew the ievr 2 ( aumatic voltage regulator ) 1.0192 2002, eqpt / system: generators / alternator make:kirlosker, 415v, 3ph, 20kva, 50hz, 1500rpm carryout routines mentioned below and prove them for satisfactory performance. ( routine may be carried out with assistance of oem or authorised rep ) . ( c ) overhauling of self starter motor for da 12v dc, make : lucas tvs 1.0193 2002, eqpt / system: generators / alternator make:kirlosker, 415v, 3ph, 20kva, 50hz, 1500rpm carryout routines mentioned below and prove them for satisfactory performance. ( routine may be carried out with assistance of oem or authorised rep ) . ( d ) renewal of self starter motor for da 12v dc, make : lucas tvs 1.0194 2002, eqpt / system: generators / alternator make:kirlosker, 415v, 3ph, 20kva, 50hz, 1500rpm carryout routines mentioned below and prove them for satisfactory performance. ( routine may be carried out with assistance of oem or authorised rep ) . ( e ) repair and overhauling of dynamo assambly 12v dc, make : lucas tvs 1.0195 2003, diesel alternator control panel 24v dc ( a ) d / g ( port & stbd ) av alaram panel system including control wiring to be completely over hauled, calibrated and proved for satisfactory operation.machinery body to be cleaned to bare metal and painted with one coat of primer and one coat of enamle paint ( white color paint from inside and gray color paint from outside ) . 1.0196 2004, diesel driven fresh water pump 28 kw, make : kirloskar ( a ) overhauling of self starter motor for dd pump 12v dc, make : lucas tvs 1.0197 2004, diesel driven fresh water pump 28 kw, make : kirloskar ( b ) renewal of self starter motor for dd pump 12v dc, make lucas tvs 1.0198 2004, diesel driven fresh water pump 28 kw, make : kirloskar ( c ) repair and overhauling of dynamo assambly 12v dc, make : lucas tvs 1.0199 2004, diesel driven fresh water pump 28 kw, make : kirloskar ( d ) renewal of dynamo assambly for dd pump 12v dc, make lucas tvs 1.02 2005, shore supply connection box 415v, 3ph, 50hz ac make : wave electronics, kochi ( firm not to quote ) following routines to be carried out 1.0201 2005, shore supply connection box 415v, 3ph, 50hz ac make : wave electronics, kochi following routines to be carried out ( a ) renew the indication lamps with holders 415v 1.0202 2005, shore supply connection box 415v, 3ph, 50hz ac make : wave electronics, kochi following routines to be carried out ( b ) mechanical cleaning of shore supply connection box to be carried out & box to be painted with one coat of primer and one coat of enamal paint ( white color paint from inside and gray color paint from outside ) . 1.0203 2005, shore supply connection box 415v, 3ph, 50hz ac make : wave electronics, kochi following routines to be carried out ( c ) following meters to be renwed : ( i ) voltmeter 0 500v 1.0204 2005, shore supply connection box 415v, 3ph, 50hz ac make : wave electronics, kochi following routines to be carried out ( c ) following meters to be renwed : ( ii ) phase sequence meter 3 phase 415v 1.0205 2006, overhauling of following motors ( a ) pump room supply fan blower motor ( 415v, 3ph, 50hz, 0.5hp ) 1.0206 2007, light fitting ( a ) renew watertight u glass light fitting incandeescent lamp fittings. 230v, 60w ( make ajmera, model 2541 ) 1.0207 2007, light fitting ( b ) repair watertight u glass light fitting incandeescent lamp fittings. 230v, 60w ( make ajmera, model 2541 ) 1.0208 2007, light fitting ( c ) repair of name plate illumination light fitting ( 220v, 20w tube ) 1.0209 2008, eqpt / system: lead acid batteries. make:exide, 200ah, 12v self maintenace free battery ( a ) renew the batteries. 1.021 2008, eqpt / system: lead acid batteries. make:exide, 200ah, 12v self maintenace free battery ( b ) renew the battery connectors ( material brass ) 1.0211 2008, eqpt / system: lead acid batteries. make:exide, 200ah, 12v self maintenace free battery ( c ) renew the short link cable ( 50sq.mm multi strand copper cables, length 0.5mtr each ) with connectors ( material copper ) 1.0212 2009, make:exide, 140ah, 12v self maintenace free battery ( a ) renew the batteries 1.0213 2009, make:exide, 140ah, 12v self maintenace free battery ( b ) renew the battery connecting lugs 1.0214 2010, eqpt / system: wall mounted electrical fans ( oscillating ) make:c&g, type 400 mm sweep ( a ) wall mounted fan repair to carry out. prove for satisfactory operation 1.0215 2010, eqpt / system: wall mounted electrical fans ( oscillating ) make:c&g, type 400 mm sweep ( b ) wall mounted fan to renew 1.0216 2011, tank content guage system input supply 220v make : nivo control pvt ltd, indore ( a ) overhauling and calibration of tank content guage system and prove them onboard for satisfactory performance 1.0217 2011, tank content guage system input supply 220v make : nivo control pvt ltd, indore ( b ) calibraton of all level sensors. renew the all sensors cable 1.0218 2012, 10kva invertor, make: m / s sukam 10kva, input 230v ac and 180 v dc, output 230v ac, 1 phase, 50 hz ( a ) overhauling of invertor to be carried out, defective component to be repair / renewed. invertor to be operationalized and load trail undertaken. invertor to be proved for satisfactory performance 1.0219 2013, eqpt / system: window wiper systems ( 24v dc ) ( a ) overhaul the gear system. motor to be overhauled. clean and lubricate windshield wiper arms. check the pivot points and cleaning of same to be carried out.rubber blades including rubber coaming to be renewed. prove window wiper system for satisfactory performance. 1.022 2013, eqpt / system: window wiper systems ( 24v dc ) ( b ) renew the blades including rubber coaming 1.0221 2013, eqpt / system: window wiper systems ( 24v dc ) 2013, eqpt / system: window wiper systems ( 24v dc ) ( c ) overhauling of window wiper ccontrol system to be carried out. prove the satisfactory operation of the window wiper system from control panel. defective components to be renewed. 1.0222 2014, provide the suitable ship electrical horn for 30mtrs to 75 mtrs length vessels sound >130db, weather proof, & rust proof material ( 24v dc stainless single trumpet type ) 1.0223 2015, portable blowers 220v, 1 ph , 50 hz, 2hp ( a ) renewal of centrifugal portable blowers 1.0224 2016, extension board rating : 220v 1ph manufacturing of extension board with 02 in no 15a sw / skt combinaion and 02 in no 5a sw / skt combination and 15 mtr 3core 2 sqmm cable along with plug top 3 pin 15a 1.0225 2017, battery charger 1.5kw, input 220v 1ph, 50hz, output 24v &12v dc ( a ) provision & & install the battery charger in pump room and prove for charging of engine starting batteries 1.0226 2017, battery charger 1.5kw, input 220v 1ph, 50hz, output 24v &12v dc ( b ) provision & install the change over mccb tp 100a ( 2way with off ) in the circuit of battery to self starter of dd engine & battery to battery charger. 1.0227 2017, battery charger 1.5kw, input 220v 1ph, 50hz, output 24v &12v dc ( c ) provision the cable ( 2x10sq.mm copper multiple strand insulated cable ) & laying of cables from battery charger to batteries via chnge over switch 1.0228 2018, battery charger 1.5kw, input 220v 1ph, 50hz, output 24v &12v dc ( d ) provide the cable ( 1x150sq.mm copper multiple strand insulated cable ) & laying of cables from batteries to self starters via chnge over switch ( the job is including material of cable lugs & battery connecting lugs ) 1.0229 dry dock and allied services work package services ( a ) docking and undocking charges ( both versions ) e. docking and undocking will be done by navy in navy permises i.e nd ( v ) / slipway dock blocks preparation & laying out as per docking plan . job will be done by navy firm not to quote 1.023 ( b ) .provision of stationory / office items for nd ( v ) / refit monitoring team for entire refit duration period. cater budget of rs 4000 / per month. requirement will be intimated rmt / ndv on as requirement basis. payment at actuals. note: firms to quote. 1.0231 dock hire charges for an estimated duration of 60 days as per ocr dry dock facility will will provided by navy in navy permises i.e nd ( v ) / slipway. firm not to quote. 1.0232 wet basin / alongside hire charges for the remaining duration each ( i.e. total refit duration of 150 days – 60 days docking period ) . dry dock facility will will provided by navy in navy permises firm not to quote 1.0233 provision of sufficient lighting for duty staff firm to quote. 1.0234 ( a ) quote for maintenance of two in no. fire lines for the refit duration . firm to quote. 1.0235 ( b ) two each connection / disconnection charges for for the refit duration firm to quote. 1.0236 provision of two transports ( cars ) for entire refit duration ( one for refit co ordinating staff and one for nd ( v ) monitoring team ) for 10 hrs or 100km / day whichever is less firm to quote....

Tirumala Tirupati Devasthanams - Andhra Pradesh

33562719 supply and installation of 3 feet dia pivot wall mounting fans (inverter control a.c.motor) to nadaneerajanam stage and bangaru vakili area of sri t.t, tirumala , supply of 3 feet dia wall mounting type pivot fan (inverter control ac motor technology) with aerodynamic aluminum blades, supporting adjustable stand length upto 8 feets and adjustable mounting bracket to work with 230v, single phase ac system.,installation charges...

South Central Railway - Andhra Pradesh

33531012 supply of a.c. fuel pump motor 1.5 h.p with built in invertor to supply 72 volts as per rdso specn. no. mp.0.24.00.20.(rev.02) january 2019.a.c. fuel pump motor 1.5 h.p with built in invertor to supply 72 volts as per rdso specn. no. mp.0.24.00.20.(rev.02) january 2019.,a.c. fuel pump motor 1.5 h.p with built in invertor to supply 72 volts as per rdso specn. no. mp.0.24.00.20.(rev.02) january 2019....

South Central Railway - Andhra Pradesh

33530851 supply of a.c. crank case motor 0.5 h.p with built in invertor to supply 72 volt as per rdso specn .no. mp.0.24.00.20, (rev. 02) january 2019..a.c. crank case motor 0.5 h.p with built in invertor to supply 72 volt as per rdso specn .no. mp.0.24.00.20, (rev. 02) january 2019..,a.c. crank case motor 0.5 h.p with built in invertor to supply 72 volt as per rdso.specn.no. mp.0.24.00.20, (rev. 02) january 2019.....

Indian Navy - Andhra Pradesh

33472111 procurement of ccs mk ii and mk iii procurement of ccs mk ii and mk iii , item , asm controller card ( 6x6 ) , e1 mux / de mux , power supply module 175w ( smps ) , res varwwg lsa bm 1k+ 5% 0.75 , crystal 999khz , extender card , set of fuses ( part of rt 674 / e ) , dc / dc converter , ic ff4013b , cable assy ( vdic 2 ) , cable assy ( adac ) , ssd ic dgtl mem ds 1225 ad 150 , lan controller , crystal qtz 11.059 mhz , cable assy ( vdic 1 ) , intel m vme sbc ( 512mb compact flash ) , radar video generator card , synthesizer , e cat 6 stp 100 mtr roll , temperature sensor , morse keyassy ( itu ) , preamplifier combiner , inverter pcb assy ( for ss 500 / e ) , cable assy itu , filter / coupler , ssd ic dgtl pmem 22v10h25 / bla , vdic serial , accessories for msk demodulator...

National Thermal Power Corporation Limited - Andhra Pradesh

33463968 procurement of spares for sesipl make inverters for ntpc feroz gandhi procurement of spares for sesipl make inverters for ntpc feroz gandhiunchahar. , atv71 v aic cheetah ctrl s / a b.i.f se , 630kva, 350v ac:assy pcba gd 15 vp , cirkt brkr ac nw20 h2 3 pol;0j 530 2148 , fan module k3g280 au06 b8 ;#0j 490 0175...

Private Company - Andhra Pradesh

33404387 auction sale of bull dozer, rock crawler drill, wagon drill, hydraulic drill jumbo, inverter welding machine, power generator, bus etc. (location vishakhapantnam. ap)...

Endowment Department - Andhra Pradesh

33382517 supply of c.c tv materials year 2022 23 , ups 600mah 15 for poes backup power, 8ch poes giga port, 4ch poes giga port, media converters giga por, switchs 8 port giga, weather proof cat 6 boundless, honey well rj45 clips, laptop for ip cameras configuration in field work, networing tool kit, adaptors 12v, steel boxes to arrange power hubs, inverters 1050 with battery 180mah monitor section and nvr section, splicing machine for fiber work fujikura 38s or equivalent single fusion splicer with stripper cleavers all accessories and box, ofc 12ft, ofc 6ft...

South Central Railway - Andhra Pradesh

33320003 comprehensive annual maintenance contract of m / s. medha make 180kva static inverters through oem for a period of three ( 03 ) years at electric loco shed vijayawada, electric loco shed kazipet, diesel loco shed kazipet & diesel loco shed guntakal qty:71 nos. ( els / bza:25 nos., els / kzj:14 nos., dsl / kzj:16 nos. & dsl / gtl:16 nos. ) comprehensive annual maintenance contract of m / s. medha make 180kva static inverters through oem for a period of three ( 03 ) years at electric loco shed vijayawada, electric loco shed kazipet, diesel loco shed kazipet & diesel loco shed guntakal qty:71 nos. ( els / bza:25 nos., els / kzj:14 nos., dsl / kzj:16 nos. & dsl / gtl:16 nos. ) , ...

Sri Padmavati Mahila Visvavidyalayam - Andhra Pradesh

33241217 supply and installation of commissioning and testing of 8 ton packaged air conditioner at university computer centre, s p mahila visvavidyalayam, tirupati. , 8.0 ton packaged inverter model air conditioner, erecting / installation of air conditioner, supply fabrication and erection of canvas, 18g copper piping, pvc drain pipe, 1.5 sqmm transmission cable between idu to odu, independent gi earth pits, 8 swg copper wire, 25mm x 3mm copper flat, 25mm x 6mm gi flat, earth work excavation for cable laying, buy back of old air conditioners, supply and charging of refrigerant gas...

South Central Railway - Andhra Pradesh

33194841 supply of 400 amps igbt inverter based manual metal400 amps igbt inverter based manual metal,400 amps igbt inverter based manual metal arc welding machine to model no.tornado401 of ador fontech or equivalent models of fronious or esab (full description at annexure 1) note: oem/authorized dealer can only participate in the tender and to be submit authorized dealer certificate while participating in the tender...

South Central Railway - Andhra Pradesh

33189943 supply of 400 amps igbt inverter based manual400 amps igbt inverter based manual,400 amps igbt inverter based manual metal arc welding machine to model no.tornado401 of ador fontech or equivalent models of fronious or esab (full description at annexure 1)...